Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

Catalog

Filters

Filters

Reset

Application area

Type

Industry

Brand name

Parameters

Measurement Range

Light source

Wavelength range

Accuracy

Compatibility

Wavelength resolution

Operating mode

Measurement method

Pre-programmed methods

Power supply

Number of inputs

Operating temperature range

Features

Sensor type

Method

Compliance with the standard

Number of tests

Measurement Range (2)

Measurement Range (3)

Cuvette compatibility

User programmes

Number of cuvettes

Heating rate

Concentration

Concentration 2

Detection angle

Units

Version

Measuring range (4)

Relative humidity

Water purity type

Water performance (type 1)

Water performance (type 2)

Water performance (type 3)

Purpose of the sampler

Fabric material

Accuracy

Response time

Sorting: 

Microx 4 trace portable oxygen meter

Microx 4 trace portable oxygen meter

PreSens Microx 4 trace is a compact, fully self-contained fiber optic oxygen meter for non-contact and microinvasive O2 measurements. Compatible with PSt7 sensors (detection limit 15 ppb, 0 - 100% oxygen) and also with PSt8 trace oxygen sensors (detection limit 3 ppb, 0 - 10% oxygen).

SKU: Microx 4 trace

View product Compare

EZ1002 / EZ1003 Ammonium Colorimetric Analyzer

EZ1002 / EZ1003 Ammonium Colorimetric Analyzer

EZ1002 is a colorimetric measurement of ammonium concentration at 630 nm based on the APHA 3500-NH3 standard method (Berthelot). EZ1003 - colorimetric measurement at 450 nm in accordance with EPA Standard Method 350.1 (Nessler).

SKU: EZ1002.99001C02, EZ1003.99001C02

View product Compare

EZ3000 / EZ3001 Ion Selective Ammonium Analyzers

EZ3000 / EZ3001 Ion Selective Ammonium Analyzers

Industrial analyzer for periodic (discontinuous) analysis of the concentration of ammonium NH4-N in water. Direct measurement with combined ion-selective electrode according to the APHA 4500-NH3 (D) standard method.

SKU: EZ3000.99001C02, EZ3001.99001C02

View product Compare

Optical point SP-PSt7-NAU for oxygen sensor PreSens

Optical point SP-PSt7-NAU for oxygen sensor PreSens

Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.

SKU: SP-PSt7-NAU, SP-PSt7-YAU

View product Compare

BOD TRAK II Manometric BOD Apparatus

BOD TRAK II Manometric BOD Apparatus

Simplify BOD analysis with BODTrak II. Results comparable to the dilution method are achieved in just two to three days. Use these results for process control or as an adjunct to a dilution method. Laboratory measuring station, control unit and stirrer with pressure transducers for 6 bottles. Measurement range 0 - 700 mg/L O2.

SKU: 2952400

View product Compare

Polymer Optical Fiber for PreSens Measuring Instruments

Polymer Optical Fiber for PreSens Measuring Instruments

Polymer optical fiber serves as a universal connector between the meter and the PreSens. POV with SMA connector is compatible with Fibox, OXY-1 SMA, OXY-1 WM, OXY mini and pH mini meters, as well as pCO2 mini. POF with ST connector is compatible with Microx 4 and OXY-1 ST series meters.

SKU: POF

View product Compare

Buffer solution for BOD, 50 tests

Buffer solution for BOD, 50 tests

Reagent pillows for BOD5 determination with the BODTrak II analyzer.

SKU: 2962266

View product Compare

BODTrak II Reagent Kit with BOD Bottles

BODTrak II Reagent Kit with BOD Bottles

Replacement kit of reagents and bottles for BOD determination.

SKU: 2952440

View product Compare

Potassium hydroxide granules, 25 g

Potassium hydroxide granules, 25 g

KOH (CO2 absorber). Used when determining BOD5 on the BODTrak II analyzer.

SKU: 31425

View product Compare

Nitrification inhibitor for BOD, Trichloromethyl Pyridine (TCMP)

Nitrification inhibitor for BOD, Trichloromethyl Pyridine (TCMP)

The BOD of carbonaceous compounds (CBOD) can be determined by adding a nitrification inhibitor. The CBOD test is recommended for biologically treated wastewater, biologically treated wastewater and river water samples.

SKU: 253335

View product Compare

Industrial titrator - Ammonium Analyzer EZ4005

Industrial titrator - Ammonium Analyzer EZ4005

The EZ4005 ammonium analyzer is a single parameter titrator with a wide measuring range: Standard measuring range: 100 - 5000 mg/L NH4-N.

SKU: EZ4005.99001C02

View product Compare

Optical point SP-PSt8-NAU for oxygen sensor PreSens

Optical point SP-PSt8-NAU for oxygen sensor PreSens

Optical points SP-PSt8-NAU and SP-PSt8-YAU for PreSens oxygen sensors allow O2 measurement in the range from 0 to 10%, detection limit - 0.007%. SP-PSt8-NAU - not autoclavable. SP-PSt8-YAU - autoclavable.

SKU: SP-PSt8-NAU, SP-PSt8-YAU

View product Compare

Oxygen Probe for In-Line Measurement OIM-PSt3

Oxygen Probe for In-Line Measurement OIM-PSt3

PreSens OIM-PSt3 is designed for process control and provides accurate and stable O2 measurements in the 0-100% / 0-45 mg / L range, with a detection limit of 0.03% / 15 ppb.

SKU: OIM-PSt3

View product Compare

Needle micro oxygen sensor NFSG-PSt7

Needle micro oxygen sensor NFSG-PSt7

The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.

SKU: NFSG-PSt7

View product Compare

Self-adhesive optical point SP-PSt3-SA for oxygen sensor PreSens

Self-adhesive optical point SP-PSt3-SA for oxygen sensor PreSens

Optical point SP-PSt3-SA for non-invasive online monitoring of oxygen in the dissolved or gaseous phase in the range of 0 - 100%, 0 - 45 mg/l.

SKU: SP-PSt3-SA

View product Compare

Oxygen sensitive PET bottle cap OSC-PSt3

Oxygen sensitive PET bottle cap OSC-PSt3

The oxygen sensitive PET bottle cap PreSens OSC-PSt3 is designed to measure oxygen penetration into opaque bottles in the range of 0 - 100% O2, 0 - 1000 hPa / 0 - 45 mg/L, 0 - 1400 μmol/L.

SKU: OSC-PSt3

View product Compare

Needle micro oxygen sensor NFSG-PSt8

Needle micro oxygen sensor NFSG-PSt8

The NFSG-PSt8 Fixed Tip Micro Needle Oxygen Sensor is designed for headspace measurement of trace oxygen or other applications where small volume measurements of gaseous oxygen are required. Has a measurement range from 0 to 10% oxygen with a detection limit of 0.007% O2.

SKU: NFSG-PSt8

View product Compare

Total Hardness Test Kit, Model 5-B

Total Hardness Test Kit, Model 5-B

The drop titration method is used, which is simple and economical.

SKU: 145300

View product Compare

Total hardness test set, model HA-71A

Total hardness test set, model HA-71A

The kit contains all the necessary reagents and accessories for determining the total hardness of water in a robust portable case for analysis in the laboratory and in the field.

SKU: 145201

View product Compare

Low range hardness reagent kit, 10 - 160 mg/l CaCO3

Low range hardness reagent kit, 10 - 160 mg/l CaCO3

The first titration gives results for the calcium hardness and the second titration gives the total hardness. The difference between the values is the level of magnesium hardness. All concentration results are given in mg/L as CaCO3.

SKU: 2448600

View product Compare

High range hardness reagent kit, 100 - 4000 mg/L as CaCO3

High range hardness reagent kit, 100 - 4000 mg/L as CaCO3

The first titration gives results for the calcium hardness and the second titration gives the total hardness. The difference between the values is the level of magnesium hardness. All concentration results are given in mg/L CaCO3.

SKU: 2448700

View product Compare

Hardness reagent kit, 4 - 1000 μg/L CaCO3

Hardness reagent kit, 4 - 1000 μg/L CaCO3

Determination of ultra-low level of water hardness by the chlorophosphonazo method.

SKU: 2603101

View product Compare

Oxygen Probe for In-Line Measurement OIM-PSt6

Oxygen Probe for In-Line Measurement OIM-PSt6

PreSens OIM-PSt6 is designed for process control and provides accurate and stable O2 measurements in the 0-5% / 0-2 mg/L range, with a detection limit of 0.002% / 1 ppb.

SKU: OIM-PSt6

View product Compare

Oxygen sensitive PET bottle cap OSC-PSt6

Oxygen sensitive PET bottle cap OSC-PSt6

The oxygen sensitive PET bottle cap PreSens OSC-PSt6 is designed to measure oxygen penetration in colored bottles in the range of 0 - 5% O2 / 0 - 2 mg/l.

SKU: OSC-PSt6

View product Compare


Sorting: 

Microx 4 trace portable oxygen meter

Microx 4 trace portable oxygen meter

PreSens Microx 4 trace is a compact, fully self-contained fiber optic oxygen meter for non-contact and microinvasive O2 measurements. Compatible with PSt7 sensors (detection limit 15 ppb, 0 - 100% oxygen) and also with PSt8 trace oxygen sensors (detection limit 3 ppb, 0 - 10% oxygen).

SKU: Microx 4 trace

View product Compare

EZ1002 / EZ1003 Ammonium Colorimetric Analyzer

EZ1002 / EZ1003 Ammonium Colorimetric Analyzer

EZ1002 is a colorimetric measurement of ammonium concentration at 630 nm based on the APHA 3500-NH3 standard method (Berthelot). EZ1003 - colorimetric measurement at 450 nm in accordance with EPA Standard Method 350.1 (Nessler).

SKU: EZ1002.99001C02, EZ1003.99001C02

View product Compare

EZ3000 / EZ3001 Ion Selective Ammonium Analyzers

EZ3000 / EZ3001 Ion Selective Ammonium Analyzers

Industrial analyzer for periodic (discontinuous) analysis of the concentration of ammonium NH4-N in water. Direct measurement with combined ion-selective electrode according to the APHA 4500-NH3 (D) standard method.

SKU: EZ3000.99001C02, EZ3001.99001C02

View product Compare

Optical point SP-PSt7-NAU for oxygen sensor PreSens

Optical point SP-PSt7-NAU for oxygen sensor PreSens

Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.

SKU: SP-PSt7-NAU, SP-PSt7-YAU

View product Compare

BOD TRAK II Manometric BOD Apparatus

BOD TRAK II Manometric BOD Apparatus

Simplify BOD analysis with BODTrak II. Results comparable to the dilution method are achieved in just two to three days. Use these results for process control or as an adjunct to a dilution method. Laboratory measuring station, control unit and stirrer with pressure transducers for 6 bottles. Measurement range 0 - 700 mg/L O2.

SKU: 2952400

View product Compare

Polymer Optical Fiber for PreSens Measuring Instruments

Polymer Optical Fiber for PreSens Measuring Instruments

Polymer optical fiber serves as a universal connector between the meter and the PreSens. POV with SMA connector is compatible with Fibox, OXY-1 SMA, OXY-1 WM, OXY mini and pH mini meters, as well as pCO2 mini. POF with ST connector is compatible with Microx 4 and OXY-1 ST series meters.

SKU: POF

View product Compare

Buffer solution for BOD, 50 tests

Buffer solution for BOD, 50 tests

Reagent pillows for BOD5 determination with the BODTrak II analyzer.

SKU: 2962266

View product Compare

BODTrak II Reagent Kit with BOD Bottles

BODTrak II Reagent Kit with BOD Bottles

Replacement kit of reagents and bottles for BOD determination.

SKU: 2952440

View product Compare

Potassium hydroxide granules, 25 g

Potassium hydroxide granules, 25 g

KOH (CO2 absorber). Used when determining BOD5 on the BODTrak II analyzer.

SKU: 31425

View product Compare

Nitrification inhibitor for BOD, Trichloromethyl Pyridine (TCMP)

Nitrification inhibitor for BOD, Trichloromethyl Pyridine (TCMP)

The BOD of carbonaceous compounds (CBOD) can be determined by adding a nitrification inhibitor. The CBOD test is recommended for biologically treated wastewater, biologically treated wastewater and river water samples.

SKU: 253335

View product Compare

Industrial titrator - Ammonium Analyzer EZ4005

Industrial titrator - Ammonium Analyzer EZ4005

The EZ4005 ammonium analyzer is a single parameter titrator with a wide measuring range: Standard measuring range: 100 - 5000 mg/L NH4-N.

SKU: EZ4005.99001C02

View product Compare

Optical point SP-PSt8-NAU for oxygen sensor PreSens

Optical point SP-PSt8-NAU for oxygen sensor PreSens

Optical points SP-PSt8-NAU and SP-PSt8-YAU for PreSens oxygen sensors allow O2 measurement in the range from 0 to 10%, detection limit - 0.007%. SP-PSt8-NAU - not autoclavable. SP-PSt8-YAU - autoclavable.

SKU: SP-PSt8-NAU, SP-PSt8-YAU

View product Compare

Oxygen Probe for In-Line Measurement OIM-PSt3

Oxygen Probe for In-Line Measurement OIM-PSt3

PreSens OIM-PSt3 is designed for process control and provides accurate and stable O2 measurements in the 0-100% / 0-45 mg / L range, with a detection limit of 0.03% / 15 ppb.

SKU: OIM-PSt3

View product Compare

Needle micro oxygen sensor NFSG-PSt7

Needle micro oxygen sensor NFSG-PSt7

The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.

SKU: NFSG-PSt7

View product Compare

Self-adhesive optical point SP-PSt3-SA for oxygen sensor PreSens

Self-adhesive optical point SP-PSt3-SA for oxygen sensor PreSens

Optical point SP-PSt3-SA for non-invasive online monitoring of oxygen in the dissolved or gaseous phase in the range of 0 - 100%, 0 - 45 mg/l.

SKU: SP-PSt3-SA

View product Compare

Oxygen sensitive PET bottle cap OSC-PSt3

Oxygen sensitive PET bottle cap OSC-PSt3

The oxygen sensitive PET bottle cap PreSens OSC-PSt3 is designed to measure oxygen penetration into opaque bottles in the range of 0 - 100% O2, 0 - 1000 hPa / 0 - 45 mg/L, 0 - 1400 μmol/L.

SKU: OSC-PSt3

View product Compare

Needle micro oxygen sensor NFSG-PSt8

Needle micro oxygen sensor NFSG-PSt8

The NFSG-PSt8 Fixed Tip Micro Needle Oxygen Sensor is designed for headspace measurement of trace oxygen or other applications where small volume measurements of gaseous oxygen are required. Has a measurement range from 0 to 10% oxygen with a detection limit of 0.007% O2.

SKU: NFSG-PSt8

View product Compare

Total Hardness Test Kit, Model 5-B

Total Hardness Test Kit, Model 5-B

The drop titration method is used, which is simple and economical.

SKU: 145300

View product Compare

Total hardness test set, model HA-71A

Total hardness test set, model HA-71A

The kit contains all the necessary reagents and accessories for determining the total hardness of water in a robust portable case for analysis in the laboratory and in the field.

SKU: 145201

View product Compare

Low range hardness reagent kit, 10 - 160 mg/l CaCO3

Low range hardness reagent kit, 10 - 160 mg/l CaCO3

The first titration gives results for the calcium hardness and the second titration gives the total hardness. The difference between the values is the level of magnesium hardness. All concentration results are given in mg/L as CaCO3.

SKU: 2448600

View product Compare

High range hardness reagent kit, 100 - 4000 mg/L as CaCO3

High range hardness reagent kit, 100 - 4000 mg/L as CaCO3

The first titration gives results for the calcium hardness and the second titration gives the total hardness. The difference between the values is the level of magnesium hardness. All concentration results are given in mg/L CaCO3.

SKU: 2448700

View product Compare

Hardness reagent kit, 4 - 1000 μg/L CaCO3

Hardness reagent kit, 4 - 1000 μg/L CaCO3

Determination of ultra-low level of water hardness by the chlorophosphonazo method.

SKU: 2603101

View product Compare

Oxygen Probe for In-Line Measurement OIM-PSt6

Oxygen Probe for In-Line Measurement OIM-PSt6

PreSens OIM-PSt6 is designed for process control and provides accurate and stable O2 measurements in the 0-5% / 0-2 mg/L range, with a detection limit of 0.002% / 1 ppb.

SKU: OIM-PSt6

View product Compare

Oxygen sensitive PET bottle cap OSC-PSt6

Oxygen sensitive PET bottle cap OSC-PSt6

The oxygen sensitive PET bottle cap PreSens OSC-PSt6 is designed to measure oxygen penetration in colored bottles in the range of 0 - 5% O2 / 0 - 2 mg/l.

SKU: OSC-PSt6

View product Compare