The versatile analyzer base unit provides flawless real-time duplication of a standard / laboratory method for determining concentrations of substances with unmatched accuracy.

The EZ1000 series analyzers use the colorimetric method to measure ammonium concentration:

  • EZ1002 Berthelot method, standard measuring range: 0.025 - 1 mg/L NH4-N
  • EZ1003 Nessler method, standard measuring range: 0.25 - 2 mg/L NH4-N

Applications: waste water, drinking water, surface water, power generation.


Description

Description

The sampling line transfers the sample to the analyzer. The analyzer uses pumps, valves, and syringes to move the sample and reagents into a measuring cell on the analytical panel. When the measurement cycle is complete, the analyzer removes the sample through the drain line. The analysis results are displayed on the data processing panel display. The data processing panel controls and configures the analyzer. It also stores analyzer data (such as trends, alarms, analysis results, and data log files).

  • The standard measuring range can be narrowed with a different calibration range or extended with internal dilution options.
  • Analog and digital output options
  • Multi-threaded analysis - up to 8 threads.

Many additional options are available. Please contact us for more details.

Optional measuring ranges for EZ1002

  • 0.005 - 0.1 mg/L NH4-N
  • 0.01 - 0.25 mg/L NH4-N
  • 0.01 - 0.5 mg/L NH4-N
  • 0.2 - 4 mg/L NH4-N (with internal dilution)
  • 0.4 - 8 mg/L NH4-N (with internal dilution)
  • 2.5 - 100 mg/L NH4-N (with internal dilution)

Optional measuring ranges for EZ1003

  • 1 - 8 mg/L NH4-N (with internal dilution)
  • 2 - 16 mg/L NH4-N (with internal dilution)
  • 2.5 - 200 mg/L NH4-N (with internal dilution)

Description of methods for the determination of ammonium

EZ1002: determination of ammonium concentration in water is based on the reaction of ammonium ions with hypochlorite and thymol component in a highly alkaline medium (pH > 10) with the formation of a green complex. Absorbance is measured at 630 nm. Sodium nitroprusside is added as a catalyst to speed up the reaction. Sodium tartrate is added to prevent the precipitation of the metal hydroxide.

EZ1003: determination of ammonium concentration in water is based on the reaction of ammonia with potassium mercury iodide from Nessler's reagent in an alkaline medium to form a yellow-brown complex. Absorbance is measured at 450 nm.

The analysis vessel is cleaned and filled with fresh sample. After sampling, the initial absorbance is measured at 630/450 nm. The reagents are then added, after stirring to obtain full color development, the final absorbance value is determined. The obtained values of optical density are used to calculate the concentration of ammonium in accordance with Lambert Beer's law.

EZ1002 / EZ1003 Ammonium Analyzer Specifications

  • Measurement method EZ1002 based on APHA 3500-NH3 standard method (Berthelot); EZ1003 comply with EPA Standard Method 350.1 (Nessler);
  • Detection limit ≤ 5 μg/L / ≤ 250 μg/L;
  • Interference for EZ1002: Amino acids, hydrazine and urea. High turbidity and color of the sample. Fats, oils, proteins, surfactants and tar. For EZ1003: acetone, alcohols, aldehydes, aliphatic and aromatic amines, chlorine, glycine, organic chloramines and sulfides. High turbidity and color of the sample. Fats, oils, proteins, surfactants and tar;
  • Cycle time 25 min (dilution + 5 min) / 6 min (dilution + 5 min);
  • Automatic cleaning yes;
  • Automatic calibration 2 points; freely programmable frequency;
  • Ambient temperature 10 - 30 °C ± 4 °C at 5 - 95% relative humidity (no condensation);
  • Store reagent requirements 10 to 30 °C
  • Flow rate 100 - 300 mL/min;
  • Sample temperature 10 - 30 °C
  • Sample quality maximum particle size 100 μm, < 0.1 g/L; turbidity < 50 NTU;
  • Dimensions (H x W x D) 690 mm x 465 mm x 330 mm
  • Weight 25 kg
  • Manufacturer: AppliTek NV / SA
  • Distributor: Hach Lange GmbH
Specifications

Specifications

Application areaWastewater, Drinking water, Treatment facilities, Equipment for water utilities, Process control
TypeIndustrial
IndustryPower generation, Food and Beverage, Municipal
ParametersAmmonium
Measurement Range0.025 - 1 mg/L NH4-N
Measurement methodColorimetric
Measurement Range (2)0.25 - 2 mg/L NH4-N
Recommended products

Recommended products

Industrial titrator - Ammonium Analyzer EZ4005

Industrial titrator - Ammonium Analyzer EZ4005

The EZ4005 ammonium analyzer is a single parameter titrator with a wide measuring range: Standard measuring range: 100 - 5000 mg/L NH4-N.

SKU: EZ4005.99001C02

View product Compare

EZ3000 / EZ3001 Ion Selective Ammonium Analyzers

EZ3000 / EZ3001 Ion Selective Ammonium Analyzers

Industrial analyzer for periodic (discontinuous) analysis of the concentration of ammonium NH4-N in water. Direct measurement with combined ion-selective electrode according to the APHA 4500-NH3 (D) standard method.

SKU: EZ3000.99001C02, EZ3001.99001C02

View product Compare

Process COD analyzer EZ7000 - EZ7004 (dichromate method)

Process COD analyzer EZ7000 - EZ7004 (dichromate method)

Online titrimetric analyzers of chemical oxygen demand in wastewater. Depending on the model, the EZ700X measures COD in the range of 5 - 10,000 mg/L O2.

SKU: EZ7000.990A1C02

View product Compare

Process COD analyzer EZ7050 / EZ7051 (permanganate method)

Process COD analyzer EZ7050 / EZ7051 (permanganate method)

The EZ7050 / EZ7051 Chemical Oxygen Demand Analyzers measure O2 concentrations in the range of 1 - 20 mg/L O2 and 20 - 200 mg/L O2, respectively. Titrimetric method.

SKU: EZ7050.990A1C02, EZ7051.990A1C02

View product Compare

EZ5000 Series Alkalinity and Hardness Analyzers

EZ5000 Series Alkalinity and Hardness Analyzers

The instrument configuration "Total Hardness + Alkalinity" performs a sequence of two different titration methods: acid-base titration with a combination electrode for alkalinity determination and colorimetric titration for hardness determination in a single titration vessel. Combined measurement of two parameters in one analyzer is a convenient solution for operators and eliminates the need for additional space and the purchase of a second analyzer.

SKU: EZ5004.99001C02

View product Compare

EZ4003 Free Alkalinity Analyzer

EZ4003 Free Alkalinity Analyzer

The EZ4003 Free Alkalinity Analyzers use an acid-base titration. Standard range 100 - 2500 mg/l CaCO3.

SKU: EZ4003.99001C02

View product Compare

EZ1006 / EZ1007 Free and Total Chlorine Analyzers

EZ1006 / EZ1007 Free and Total Chlorine Analyzers

The EZ Series online analyzers offer several options for monitoring chlorine in water. Typical applications are drinking water, surface water, process water. The EZ1000 Series analyzers use colorimetric method to measure chlorine. EZ1006 Chlorine free. EZ1007 Chlorine, total. Standard measuring range: 0.025 - 1.5 mg / l Cl2.

SKU: EZ1006.99001C02, EZ1007.99001C02

View product Compare

Titrimetric analyzer of total and calcium hardness EZ4043 / EZ4041 / EZ4044

Titrimetric analyzer of total and calcium hardness EZ4043 / EZ4041 / EZ4044

The EZ4000 Series Hardness Analyzers are single parameter titrators: total hardness EZ4043 - Calmagit / EDTA method with a submersible LED probe, standard measurement range: 0.25 - 10 mg/L CaCO3; EZ4041 total hardness; calmagit / EDTA method, standard measurement range: 100 - 1000 mg/L CaCO3; EZ4044 Calcium hardness, standard measuring range: 10 - 1000 mg/L CaCO3.

SKU: EZ4041.99001C02, EZ4043.99001C02, EZ4044.99001C02

View product Compare

Colorimetric Hardness Analyzer Envirolyzer EZ1000 Series

Colorimetric Hardness Analyzer Envirolyzer EZ1000 Series

EZ1000 series analyzers use the colorimetric method of analysis: EZ1016 total hardness, EZ1017 calcium hardness, EZ1304 total hardness and calcium hardness, EZ1306 total hardness, calcium and magnesium hardness. Standard measuring range: 0.025 - 1 mg/L CaCO3.

SKU: EZ1016.99001C02

View product Compare

EZ4004 Process Total Alkalinity Analyzer

EZ4004 Process Total Alkalinity Analyzer

Online analyzer to determine the total alkalinity of water in real time.

SKU: EZ4004.99001C02

View product Compare