TL2350 Tungsten Lamp Turbidimeter, EPA, 0 - 10000 NTU

mutnomer-s-volframovoj-lampoj-tl2350.jpgDelivery set Hach TL2350 LPV444.99.00310usb port of turbidity meter TL2350 LPV444.99.00310

SKU: LPV444.99.00310

Manufacturer: Hach

Availability: Order only

Order Add to comparison

What's included: TL2350 Turbidity Meter, Silicone Oil, oiling cloth, USEPA Filter Assembly, 1 '' (30 ml) Cuvettes with Caps (6 pcs), Gelex Secondary Turbidity Standard Kit, Stablcal Calibration Standard Kit, power supply, power cable, dust cover.


Description

Description

Model TL2350 EPA. Meets EPA Method 180.1
Light source: Tungsten filament lamp.
Measurement method: nephelometric.

Measurement range:
NTU (Ratio on): 0 - 10000 auto decimal
NTU (Ratio off): 0 - 40
EBC (Ratio on): 0 - 2450 auto decimal
EBC (Ratio off): 0 - 9.8
Absorbance (auto range): 0 - 1.0
Transmittance (%): 1.0 - 100
Degree (mg /L): 1 - 100

The TL23 Series Benchtop Turbidimeters are available in four different models: two models with a tungsten lamp 460 nm and two models with a light-emitting diode (LED) 860 nm.

The TL23 Series Laboratory Turbidity Meters for a wide range of turbidity applications are equipped with Hach's robust benchtop turbidity meter technology and enhanced functionality to simplify analysis. These features include a color touch screen, USB data port, self-diagnostics for quality assurance, and one-point calibration that allows measurements below 40 NTU / FNU.

Improved and intuitive design

The large TL23 series full color touchscreen display and intuitive user interface speed setup, calibration and measurement. A simple interface and step-by-step instructions make it easy to use the tool.

Smart device for reliable measurements

The TL23 Series provides stable readings and accurate analysis by recording turbidity readings after the device detects sample stability. This step eliminates the need for repeated measurements.

Easy to use

With the TL23 series, everything you need is always at hand - a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance.

Specifications

Specifications

Application areaWastewater, Laboratory analysis, Process control
TypeLaboratory
IndustryMunicipal
ParametersTurbidity
Measurement Range0 - 10000 NTU
Power supply50 - 60 Hz, 100 - 240 V
Operating temperature range0 - 40 °C
Compliance with the standardEPA
Detection angle0° x 90°
UnitsNTU, EBC, mg/L, %T (% transmittance), Abs (absorbance)
Light sourceTungsten lamp
Video
Recommended products

Recommended products

Stablcal Turbidity Standards Calibration Kit, 0 - 4000 NTU

Stablcal Turbidity Standards Calibration Kit, 0 - 4000 NTU

Five ready to use, stabilised Formazin Primary standard solutions. Kit includes sealed vials of each: <0,1 NTU, 20 NTU, 200 NTU, 1000 NTU, 4000 NTU. 

SKU: 2662105

View product Compare

2100Q IS Portable Turbidimeter

2100Q IS Portable Turbidimeter

Hach 2100Q IS Portable Turbidity Meter offers unmatched ease of use and turbidity measurement accuracy. Only Hach offers this unique combination of advanced features and measurement innovation to deliver accurate results.

SKU: 2100QIS01

View product Compare

TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version

TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version

The TU5 Series laboratory turbidity meters with 360° x 90° technology enable accurate low range turbidity measurements. The TU5200 laboratory turbidimeter is specially designed for drinking water and other ultrapure water applications.

SKU: LPV442.99.01012

View product Compare

Stablcal Turbidity Standards Calibration Kit, 0 - 7500 NTU

Stablcal Turbidity Standards Calibration Kit, 0 - 7500 NTU

Six ready to use, stabilised Formazin Primary standard solutions. Kit includes sealed vials of each: <0,1 NTU, 20 NTU, 200 NTU, 1000 NTU, 4000 NTU, 7500 NTU.

SKU: 2659505

View product Compare

Accessories

Accessories

Stablcal Turbidity Standards Calibration Kit, 0 - 7500 NTU

Stablcal Turbidity Standards Calibration Kit, 0 - 7500 NTU

Six ready to use, stabilised Formazin Primary standard solutions. Kit includes sealed vials of each: <0,1 NTU, 20 NTU, 200 NTU, 1000 NTU, 4000 NTU, 7500 NTU.

SKU: 2659505

View product Compare

Gelex Secondary Turbidity Standard, Stray Light

Gelex Secondary Turbidity Standard, Stray Light

Gelex Secondary Turbidity Standard Stray Light, for TL2300, TL2350, TL2360, TL2310 Turbidimeters.

SKU: 2589100

View product Compare

Gelex Secondary Turbidity Standard Kit, 0 - 4000 NTU

Gelex Secondary Turbidity Standard Kit, 0 - 4000 NTU

Gelex Secondary Turbidity Standard Kit. Box and insert sold separately. Part numbers 4660100 and 2522400. Kit includes 1 sealed vial each, Stray Light Standard, 0-2 NTU, 0-20 NTU, 0-200 NTU, 200-4000 NTU.

SKU: 2589000

View product Compare

Silicone oil, 15 mL SCDB

Silicone oil, 15 mL SCDB

Silicone oil, 15 mL. Multiple uses, including preparation of turbidity sample cells, for TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 126936

View product Compare

Recommended products