TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version




SKU: LPV442.99.01012
Manufacturer: Hach
Availability: Order only
Model: TU5200 EPA
Range: 0 - 700 NTU
Light source: 650nm laser class 2
The TU5 Series benchtop turbidity meters for drinking water and other clean water applications feature 360 ° x 90° detection technology designed to see more than any other turbidity meter. Detection 360° x 90° provides sensitivity and accuracy in a low range, minimizing discrepancy between measurements. The TU5 Series benchtop turbidity meters are available in four different models with a stable laser light source: two EPA models and two ISO models, each with an additional RFID option that allows online and laboratory measurement comparisons.
Dimensions (H x W x D): 195 mm x 409 mm x 278 mm
Display: 7 '' WVGA (800 x 480) color TFT LCD with touch screen
Enclosure Construction: PC / ABS blended plastic
Description Specifications Video Recommended products Accessories
Description
Description
360 ° x 90 ° technology
The TU5 series of turbidimeters has patented optical technology that allows you to see a larger sample volume than with any other turbidimeter, providing better accuracy and sensitivity in the low range.
Comparison of laboratory and online results
Eliminates uncertainty about which measurement to trust with 360° x 90° technology in both instruments.
Time saving
The TU5 series reduces the time required to measure turbidity. This is all thanks to a 98% reduction in sample surface area that needs to be cleaned, sealed calibration vials, and the elimination of the need to use silicone oil. Not to mention, a smaller in-line sample means you'll see deviations almost immediately.
Measuring principle
The TU5 Series turbidity meters measure turbidity by aiming a laser at the sample to scatter suspended particles. Light that is scattered at a 90° angle from the incident beam is reflected by a conical mirror surrounding the sample through 360° and then strikes the detector.
The amount of scattered light is proportional to the turbidity of the sample. If the turbidity of the sample is negligible, a small amount of light will be scattered and detected by the photocell, in which case the turbidity reading will be low. High levels of turbidity will cause strong light scattering and result in high readings.
The TU5 Series 360° x 90° optical system is optimized for high accuracy at low turbidity and therefore the TU5 does not include Ratio technology. This technology is only applicable for applications with high turbidity values, in which the influence of color and large particles is present.
Specifications
Application area | Laboratory analysis |
Type | Laboratory |
Industry | Food and Beverage, Municipal |
Parameters | Turbidity |
Measurement Range | 0 - 700 NTU |
Power supply | 50 - 60 Hz, 100 - 240 V |
Operating temperature range | 10 - 40 °C |
Compliance with the standard | EPA |
Detection angle | 360° x 90° |
Units | FTU, FNU, NTU, EBC |
Light source | Laser |
Recommended products
2100Q Portable Turbidimeter (EPA)
The turbidimeter complies with the USEPA Method 180.1. This instrument offers unsurpassed ease of use and accuracy in turbidity measurements. Measurement range 0 - 1000 NTU. Light source: Tungsten filament lamp
SKU: 2100Q01
TU5200 Laboratory Laser Turbidimeter with RFID, ISO Version
The TU5 Series laboratory turbidity meters with 360 ° x 90 ° technology enable accurate low range turbidity measurements. The TU5200 laboratory turbidimeter is specially designed for drinking water and other ultrapure water applications.
SKU: LPV442.99.03022
TU5200 Laboratory Laser Turbidimeter without RFID, ISO Version
The TU5 Series laboratory turbidity meters with 360 ° x 90 ° technology enable accurate low range turbidity measurements. The TU5200 laboratory turbidimeter is specially designed for drinking water and other ultrapure water applications.
SKU: LPV442.99.01022
Accessories
Stablcal calibration kit for TU5200, TU5300sc and TU5400sc laser turbidimeters without RFID
Precise, premixed formazin solutions.
SKU: LZY898
Formazin Turbidity Standard, 4000 NTU
Formazin Turbidity Standard. Turbidity standard can be diluted to be used with any of Hach's turbidimeters TL23, TU52, 2100Q, 2100N, 2100AN series. Concentration: 4000 NTU.
SKU: 246142
Stablcal Stabilised Formazine Turbidity Standard, 1000 NTU, 100 mL / 500 mL
Ready to use, stabilised Formazine Primary standard solution in bottle, 1000 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. For TL23, TU52, 2100Q, TL2300, TL2350 series.
SKU: 2660642, 2660649
Silicone oil, 15 mL SCDB
Silicone oil, 15 mL. Multiple uses, including preparation of turbidity sample cells, for TL23, TU52, 2100Q, TL2300, TL2350 series.
SKU: 126936
Recommended products
2100Q Portable Turbidimeter (EPA)
The turbidimeter complies with the USEPA Method 180.1. This instrument offers unsurpassed ease of use and accuracy in turbidity measurements. Measurement range 0 - 1000 NTU. Light source: Tungsten filament lamp
SKU: 2100Q01
TU5200 Laboratory Laser Turbidimeter with RFID, ISO Version
The TU5 Series laboratory turbidity meters with 360 ° x 90 ° technology enable accurate low range turbidity measurements. The TU5200 laboratory turbidimeter is specially designed for drinking water and other ultrapure water applications.
SKU: LPV442.99.03022
TU5200 Laboratory Laser Turbidimeter without RFID, ISO Version
The TU5 Series laboratory turbidity meters with 360 ° x 90 ° technology enable accurate low range turbidity measurements. The TU5200 laboratory turbidimeter is specially designed for drinking water and other ultrapure water applications.
SKU: LPV442.99.01022