Needle micro oxygen sensor NFSG-PSt8

presens-nfsg-pst8-mikrodatchik-kisloroda.jpg

SKU: NFSG-PSt8

Manufacturer: РreSens

Availability: Order only

Order Add to comparison

The NFSG-PSt8 Fixed Tip Micro Needle Oxygen Sensor is ideal for measuring trace oxygen in headspace above food in a package or for other applications where small volume measurements of oxygen gas are required.

Advantages:

  • Does not consume oxygen
  • Signal independent of flow rate
  • High spatial resolution
  • High temporal resolution (t90
  • The probe is capable of penetrating solid substances such as sediments or biofilms
  • Durable and easy to handle

Description

Description

The PreSens NFSG-PSt8 needle microsensor allows trace oxygen measurements in the range from 0 to 10% O2, with a detection limit of 0.007% O2.

The tip of this microsensor is fixed inside the steel needle and does not protrude beyond the tip. Attached in this manner to the inside of the needle, the sensor can pierce the material and determine the trace oxygen content in the smallest volumes of headspace.

Designed for use with PreSens Oximeters Microx 4, OXY-1 ST, OXY-4 ST series.

Not autoclavable as the syringe is made of polypropylene.

PreSens Oxygen Sensor Specifications

  • Measuring range: 0 - 10% O2, 0 - 100 гПа
  • Detection limit: 0.007% oxygen
  • Resolution: ± 0.002 % O2 at 0.008 % O2
                         ± 0.06 % O2 at 2.5 % O2
  • Accuracy at + 20 °C: ± 0.007 % oxygen or ± 3 % rel.
  • Temperature measurement range: 0 to + 50 °С
  • Response time (t90): less than 3 sec.
  • No cross-sensitivity with: pH 1-14, CO2, H2S, SO2, ionic forms
  • Cross-sensitivity: organic solvents such as acetone, toluene, chloroform or methylene chloride, chlorine gas
  • Sterilization: Ethylene Oxide (EtO)
  • Purification: 3 % H2O2, ethyl alcohol, soap solution
  • Calibration: two-point calibration in an oxygen-free environment (nitrogen, sodium sulfite), a second calibration value is optimal between 2% and 4% oxygen
  • Shelf life: 60 months if stored in the dark at room temperature.
Specifications

Specifications

Application areaPharmaceuticals, Food production, Beverages, Package control
TypeLaboratory
IndustryPharmaceutical, Food and Beverage
ParametersOxygen
Measurement Range0 - 100% O2
CompatibilityOximeter Microx 4 trace
Video
Recommended products

Recommended products

Microx 4 trace portable oxygen meter

Microx 4 trace portable oxygen meter

PreSens Microx 4 trace is a compact, fully self-contained fiber optic oxygen meter for non-contact and microinvasive O2 measurements. Compatible with PSt7 sensors (detection limit 15 ppb, 0 - 100% oxygen) and also with PSt8 trace oxygen sensors (detection limit 3 ppb, 0 - 10% oxygen).

SKU: Microx 4 trace

View product Compare

Oxygen Probe for In-Line Measurement OIM-PSt3

Oxygen Probe for In-Line Measurement OIM-PSt3

PreSens OIM-PSt3 is designed for process control and provides accurate and stable O2 measurements in the 0-100% / 0-45 mg / L range, with a detection limit of 0.03% / 15 ppb.

SKU: OIM-PSt3

View product Compare

Needle micro oxygen sensor NFSG-PSt7

Needle micro oxygen sensor NFSG-PSt7

The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.

SKU: NFSG-PSt7

View product Compare

Recommended products