Optical point SP-PSt7-NAU for oxygen sensor PreSens
SKU: SP-PSt7-NAU, SP-PSt7-YAU
Manufacturer: РreSens
Availability: Order only
Optical points SP-PSt7-NAU and SP-PSt7-YAU allow O2 measurement in the range from 0 to 100% with a detection limit of 0.03%. Designed to work with PreSens oxygen sensors and oximeters: Microx 4, Microx 4 trace, OXY-1 ST, OXY-1 ST trace.
Benefits:
- Non-invasive measurements through the vessel wall
- Does not consume oxygen
- Signal independent of flow rate
- Accurate oxygen measurement in both liquid and gas phase
Description Specifications Video Recommended products Accessories
Description
Description
Optical points PreSens SP-PSt7-NAU and SP-PSt7-YAU can be built into any transparent or semitransparent container or optical window, while measurements are performed non-invasively from the outside - through the container wall. Due to their small size, these sensors are the most versatile and can be used in many applications to measure dissolved and gaseous O2. For example, in the development of bioprocesses (monitoring oxygen in shake flasks), measuring photosynthesis and cellular respiration of various organisms, bacteria, cell cultures, yeast or fungi.
These oxygen sensor points have a measuring range of 0 to 100% O2 with a detection limit of 0.03% O2.
SP-PSt7-NAU - is not autoclavable.
SP-PSt7-YAU - autoclavable.
PreSens Optical Point Specifications
- Measurement range:
Gaseous and dissolved O2: 0 - 100% O2, 0 - 1000 hPa
Dissolved O2: 0 - 45 mg / L, 0 - 1400 μmol / L - Detection limit:
Gaseous and dissolved O2: 0.03% oxygen
Dissolved O2: 15 ppb - Resolution:
Gaseous and Dissolved O2:
± 0.01% O2 at 1% O2
± 0.05% O2 @ 20.9% O2
Dissolved O2:
± 0.005 mg / L at 0.4 mg / L
± 0.025 mg / L at 9.06 mg / L - Accuracy at + 20 ° C: ± 0.05% O2 or ± 3% RH
- Temperature measuring range: 0 - 50 ° C
- Response time (t90):
Gaseous and dissolved O2: < 6 sec
Dissolved O2: < 40 sec - Compatibility: aqueous solutions, ethanol, methanol
- Not sensitive to: pH 1 - 14, CO2, H2S, SO2, ionic forms
- Sensitivity to: organic solvents such as acetone, toluene, chloroform or methylene chloride, chlorine gas
- Sterilization: Ethylene Oxide (EtO) (for SP-PSt7-YAU also steam sterilization access)
- Purification: 3% H2O2, ethanol, soap solution (for SP-PSt7-YAU also available CIP, 2% NaOH, + 80 ° C, + 176 ° F)
- Calibration: two-point calibration in an oxygen-free environment (nitrogen, sodium sulfite) and in an environment saturated with air
- Shelf life: 60 months when stored in the dark at room temperature
Various optics are available for ordering depending on diameter (3, 5, 7, 10 mm) and material: PTFE, USP Class VI (YOP), food safe (CAF).
For the SP-PSt7-NAU, in addition to the materials listed above, optical points with a fast response time, not autoclavable (OIW) are available.
Specifications
Application area | Environmental monitoring, Pharmaceuticals, Food production, Beverages |
Type | Portable |
Industry | Ecology, Pharmaceutical, Food and Beverage |
Parameters | Dissolved oxygen, Oxygen |
Measurement Range | 0 - 100% O2 |
Compatibility | Oximeter Microx 4 trace |
Recommended products
Optical point SP-PSt3-NAU for oxygen sensor PreSens
The optical point is the most versatile version of the non-invasive optical oxygen sensors. SP-PSt3-NAU has a measuring range from 0 to 100% oxygen in dissolved or gas phase
SKU: SP-PSt3-NAU
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Optical point SP-PSt8-NAU for oxygen sensor PreSens
Optical points SP-PSt8-NAU and SP-PSt8-YAU for PreSens oxygen sensors allow O2 measurement in the range from 0 to 10%, detection limit - 0.007%. SP-PSt8-NAU - not autoclavable. SP-PSt8-YAU - autoclavable.
SKU: SP-PSt8-NAU, SP-PSt8-YAU
Accessories
PreSens IS-SP Optical Point Integration Kit
The kit is specially designed for easy and convenient movement of PreSens optical points even in tall and hard-to-reach containers. It can be used to integrate PreSens self-adhesive points, such as SP-PSt3-SA, and SP-PSt3, SP-PSt6, SP-PSt9 optical points into containers, using liquid glue.
SKU: IS-SP
Related products
Microx 4 trace portable oxygen meter
PreSens Microx 4 trace is a compact, fully self-contained fiber optic oxygen meter for non-contact and microinvasive O2 measurements. Compatible with PSt7 sensors (detection limit 15 ppb, 0 - 100% oxygen) and also with PSt8 trace oxygen sensors (detection limit 3 ppb, 0 - 10% oxygen).
SKU: Microx 4 trace
Show more
Recommended products
Optical point SP-PSt3-NAU for oxygen sensor PreSens
The optical point is the most versatile version of the non-invasive optical oxygen sensors. SP-PSt3-NAU has a measuring range from 0 to 100% oxygen in dissolved or gas phase
SKU: SP-PSt3-NAU
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Optical point SP-PSt8-NAU for oxygen sensor PreSens
Optical points SP-PSt8-NAU and SP-PSt8-YAU for PreSens oxygen sensors allow O2 measurement in the range from 0 to 10%, detection limit - 0.007%. SP-PSt8-NAU - not autoclavable. SP-PSt8-YAU - autoclavable.
SKU: SP-PSt8-NAU, SP-PSt8-YAU