DR3900 Spectrophotometer with RFID technology





SKU: LPV440.99.00001
Manufacturer: Hach
Availability: In stock
The DR3900 is a benchtop visible spectrum spectrophotometer (320-1100 nm) with over 220 pre-programmed methods optimized for laboratory water analysis.
The kit includes:
- Spectrophotometer DR3900;
- Adapter "A" for 1 "round cuvettes and 1 cm Accuvac rectangular cuvettes
- user's manual
- power supply 100 - 240 V, 47 - 63 Hz
- Operator RFID tag
Description Specifications Video Recommended products Accessories
Description
Description
The DR3900 is a split-beam visible spectrum (320-1100 nm) laboratory spectrophotometer with over 220 pre-programmed methods optimized for laboratory water analysis. Keeping in mind your daily water analysis routine, the DR3900 spectrophotometer is optimized for process safety and accurate results. Control parameters such as ammonium, COD, phosphate, nitrate and many others are easy to implement. Work with tests / reagents and a spectrophotometer is thought out to the smallest detail, eliminating errors in water analysis.
Simple preparation
Boxes and cuvettes are color-coded for quick and easy identification of parameters and ranges. Illustrated step-by-step test methods are printed on the box as a quick reference or can be called up from the instrument menu.
The DR3900 spectrophotometer uses RFID technology to provide reliable communication with the sampling device and samples. Just hold the cuvette label over the RFID sensor.
Fast execution
A new 2D barcode indicates the lot number and expiration date of the reagents. During the measurement process, the DR3900 immediately collects all information from the cuvette using the IBR + barcode reader. If the expiration date has already passed, an automatic warning will be issued.
Method updates are also identified by a 2D barcode. Calibration data is included in the RFID tag on the box to automatically update with the RFID module.
Complete documentation
Measurement results are documented at a detailed level with time stamp, operator ID, absorbance readings and calculated concentration. The 2D barcode contains the batch number and expiration date, which are recorded with each result. For your accreditation, the Certificate of Analysis can be called up by simply wiping the reagent box near the RFID sensor.
Customizable to the needs of the user
With the ability to store hundreds of user-defined methods, operators can tailor the DR3900 to the daily needs of the enterprise.
The ability to optimize and customize the portfolio of methods, combined with regular software updates and connectivity to Claros, make the DR3900 the ideal solution for laboratory water quality testing.
Measured Parameters
Alkalinity | Manganese |
Aluminum | Mercury |
Ammonia | Molybdenum |
Ammonia, Free | Monochloramine |
Anammox Activity | Nickel |
Arsenic | Nitrate |
Barium | Nitrite |
Benzotriazole / Tolyltriazole | Nitrogen, Ammonia |
Boron | Nitrogen, Total |
Bromine | Nitrogen, Total Inorganic (TIN) |
Cadmium | Nonionic surfactants |
Cationic Surfactants | Oxygen Scavengers |
Chloride | Ozone |
Chlorine Dioxide | PCB (Polychlorinated Biphenyls) |
Chlorine, Free | Peracetic Acid (PAA) |
Chlorine, Total | Phenols |
Chromium, Hexavalent | Phosphonates |
Chromium, Hexavalent and Total | Phosphorus |
Chromium, Total | Potassium |
Cobalt | Quaternary Ammonium Compounds |
COD (Chemical Oxygen Demand) | Selenium |
Color | Silica |
Copper | Silver |
Cyanide | Sulfate |
Cyanuric Acid | Sulfide / Hydrogen Sulfide |
Detergents / Surfactants | Sulfite |
Dissolved Oxygen | Suspended Solids |
Fluoride | Tannin and Lignin |
Formaldehyde | TKN |
Hardness | Total Organic Carbon (TOC) |
Hydrazine | Toxicity |
Hydrogen Peroxide | TPH in Soil |
Iodine | Trihalomethanes, Total (THM) |
Iron | Volatile Acids |
Lead | Zinc |
Magnesium, Total |
Specifications
Application area | Environmental monitoring, Wastewater, Food production, Drinking water, Treatment facilities, Laboratory analysis, Process control, Soil analysis |
Type | Laboratory |
Industry | Power generation, Transport, Chemical, Food and Beverage, Municipal |
Parameters | Bromine, BOD, Boron, Benzotriazole, Barium, Ammonium, Ammonia, Aluminum, Sludge activity, Nitrogen total Kjeldahl, Nitrogen total, Phosphorus total, Phosphonates, Phosphate, Formaldehyde, Phenols, Trihalomethanes, Tolyltriazole, Tannin and Lignin, Sulfite, Sulfide, Sulfate, Alcohol, Salinity, Ammonium compounds quaternary, Silver, Plumbum, Mercury, Dissolved oxygen, Deoxidizers, Hydrogen peroxide, Surfactants nonionic, Surfactant cationic, Surfactant anionic, Orthophosphates, Organic acids, TOC, Tin, Oxidizability, Ozone, Nitrite, Nitrate, Nickel, Sodium, Turbidity, Molybdenum, Molybdate, Menthol, Copper, Manganese, Magnesium, Volatile acids, Silicon, Cobalt, Carbon dioxide, Potassium, Cadmium, Iodine, Hardness Ca and Mg, Water hardness residual, Hardness of water, Hardness, Iron, Bitterness units, Chlorine dioxide, Hydrazine, Vicinal diketones, AOX (Absorbable halogen organic compounds), Zirconium, Zinc, Cyanuric acid, Cyanide, Chromaticity, Colour, Chromium, COD, Chloride, Chloramine mono, Chlorine free, Chlorine total, Chlorine, Fluorine, Photometric sample for iodine, Phosphorus ortho, Zinc trace, Formaldehyde trace, Starch, Anammox Activity |
Measurement Range | ± 3 Abs (wavelength range 340 - 900 nm) |
Light source | Tungsten (VIS) |
Wavelength range | 320 -1100 nm |
Compatibility | Cuvette test system LCK, Ampoule reagents, Powder reagents |
Wavelength resolution | 1 nm |
Operating mode | Scanning, Absorbance and Concentration, Transmittance (%) |
Pre-programmed methods | > 220 |
Power supply | 50 - 60 Hz, 100 - 240 V |
Features | RFID technology |
Cuvette compatibility | Round: 13 mm, 1 inch, Rectangular: 10, 20, 30, 50 mm, 1 inch |
Recommended products
LCK1414, COD cuvette test 5 - 60 mg/L O2
COD reagent kit, measuring range 5 - 60 mg/L O2.
SKU: LCK1414
LCK339 Nitrate cuvette test, 0,23 - 13,5 mg/L NO3-N
Reagent kit for the determination of Nitrate, measuring range 0,23 - 13,5 mg/L NO3-N.
SKU: LCK339
LCK337 Nickel cuvette test, 0,1 - 6,0 mg/L Ni
Reagent kit for nickel, measurement range 0,1 - 6,0 mg / L Ni.
SKU: LCK337
LCK228 Potassium cuvette test, 5 - 50 mg/L K
Potassium reagent kit, measuring range 5 - 50 mg / L K.
SKU: LCK228
Nitrogen, Ammonia TNT, 0,4 - 50,0 mg/L NH3-N
Reagent kit Nitrogen, Ammonia TNT, measuring range 0,4 - 50,0 mg/L NH3-N.
SKU: 2606945
Accessories
Glass cuvette Hach square 1 inch (25 mm), 2 pcs.
Photometric vials. For use with Hach DR1900, DR6000, DR3900 spectrophotometers.
SKU: 2495402, 2495408
Replacement halogen bulb for DR3900 / DR2700 / DR2800 / DR3800 / Lico 500
Replaceable halogen lamp. Suitable for use with Hach DR3900 / DR2700 / DR2800 / DR3800 / Lico 500 spectrophotometers.
SKU: LZV565
DR/Check Absorbance Standard Kit (Set of 4)
A set of standards (4 pieces) for checking photometric accuracy to confirm the consistent response of a spectrophotometer or colorimeter.
SKU: 2763900
Adapter A for DR3900 Spectrophotometer
Replacement adapter for sample cells.
SKU: LZV846
Related products
LCK014, COD cuvette test 1000 - 10000 mg/L O2
COD reagent kit, measuring range 1000 - 10000 mg/L O2.
SKU: LCK014
LCK314 COD cuvette test, 15 - 150 mg/L O2
Ragents set for COD determination, measuring range 15 - 150 mg/L O2
SKU: LCK314
LCK303 Ammonium cuvette test, 2,0 - 47,0 mg/L NH4-N
Reagent kit LCK303 for the determination of Ammonium, measuring range: 2,0 - 47,0 mg/L NH4-N / 2,5 - 60 mg/L NH4.
SKU: LCK303
LCK349 Phosphate (Ortho/Total) cuvette test 0,05 - 1,5 mg/L PO4-P
Phosphate reagent kit (Ortho/Total), measuring range 0,05 - 1,5 mg/L PO4-P / 0,15 - 4,5 mg/L PO4.
SKU: LCK349
LCK348 Phosphate Ortho/Total cuvette test 0,5 - 5,0 mg/L PO4-P
Phosphate reagent kit (Ortho/Total), measuring range 0,5 - 5,0 mg/L PO4-P.
SKU: LCK348
LCK304 Ammonium cuvette test, 0,015 - 2,0 mg/L NH4-N
Reagent kit LCK304 for the determination of Ammonium, measuring range 0,015 - 2,0 mg/L NH4-N / 0,02 - 2,5 mg/L NH4.
SKU: LCK304
LCK514 COD cuvette test, 100 - 2000 mg/L O2
COD test kit, measuring range 100 - 2000 mg/L O2.
SKU: LCK514
LCK321 Iron cuvette test 0,2 - 6,0 mg/L Fe
A set of reagents for the determination of iron, measuring range 0.2 - 6.0 mg / l Fe.
SKU: LCK321
Show more
Recommended products
LCK1414, COD cuvette test 5 - 60 mg/L O2
COD reagent kit, measuring range 5 - 60 mg/L O2.
SKU: LCK1414
LCK339 Nitrate cuvette test, 0,23 - 13,5 mg/L NO3-N
Reagent kit for the determination of Nitrate, measuring range 0,23 - 13,5 mg/L NO3-N.
SKU: LCK339
LCK337 Nickel cuvette test, 0,1 - 6,0 mg/L Ni
Reagent kit for nickel, measurement range 0,1 - 6,0 mg / L Ni.
SKU: LCK337
LCK228 Potassium cuvette test, 5 - 50 mg/L K
Potassium reagent kit, measuring range 5 - 50 mg / L K.
SKU: LCK228
Nitrogen, Ammonia TNT, 0,4 - 50,0 mg/L NH3-N
Reagent kit Nitrogen, Ammonia TNT, measuring range 0,4 - 50,0 mg/L NH3-N.
SKU: 2606945