Oxygen Probe for In-Line Measurement OIM-PSt6

SKU: OIM-PSt6
Manufacturer: РreSens
Availability: Order only
The OIM-PSt6 oxygen probe for in-line measurement and process control provides accurate and reliable O2 measurements in the 0-5% / 0-2 mg/L range.
Advantages:
- Autoclavable: SIP (+ 130 °C, 1.5 atm) and CIP (2% NaOH, + 80 °C)
- Use after autoclaving without recalibration.
- No need to clean and replace the membrane
- No need to replenish electrolyte solutions
- Pressure resistant
- No polarization
- Long shelf life
Description Specifications Recommended products Accessories
Description
Description
The PreSens OIM-PSt6 connects to an oxygen meter (oximeter) via optical fiber, has a standardized thread and length, and is compatible with most bioreactors and port adapters.
OIM-PSt6 in-line oxygen probe consists of a stainless steel fitting with an optical replaceable cap in which an oxygen sensor is integrated. The optical interchangeable cap is screwed onto the top of the metal fitting and can be easily replaced if required.
The PreSens sensor provides highly accurate oxygen measurements, very fast response times and is virtually maintenance-free as it contains no membranes or electrolytes. The sensor is fully autoclavable and sterilizable (CIP and SIP).
In-line oxygen sensors are ideal for use in harsh environments such as high pressure or oil / water mixtures. For example, to monitor and control production processes in biotechnology, pharmaceuticals, brewing and beverage industries.
Technical characteristics of the oxygen probe PreSens OIM-PSt6
- Measurement range:
Gaseous and dissolved O2: 0 - 5% O2, 0 - 41.4 hPa
Dissolved O2: 0 - 2 mg / L, 0 - 56.9 μmol / L - Detection limit:
Gaseous and dissolved O2: 0.002% oxygen
Dissolved O2: 1 ppb - Resolution:
Gaseous and Dissolved O2:
± 0.0007% O2 at 0.002% O2
± 0.0015% O2 at 0.2% O2
± 0.007 hPa at 0.023 hPa
± 0.015 hPa at 2.0 hPa
Dissolved O2:
± 0.0003 mg / L at 0.001 mg / L
± 0.0006 mg / L at 0.09 mg / L
± 0.010 μmol / L at 0.03 μmol / L
± 0.020 μmol / L at 2.8 μmol / L - Accuracy: ± 1 ppb or ± 3% of the corresponding concentration
- Drift: at 0% oxygen less than 2 ppb for 30 days (sampling interval 1 min.)
- Temperature measurement range: from 0 to + 50 ° С
- Response time (t90):
Gaseous and dissolved O2: less than 6 sec.
Dissolved O2: less than 40 sec. - Compatibility: aqueous solutions, ethanol, methanol
- No transverse sensitivity with: pH 1 - 14, CO2, H2S, SO2, ionic forms
- Cross-sensitivity: organic solvents such as acetone, toluene, chloroform or methylene chloride, chlorine gas
- Sterilization: Ethylene oxide (EtO), steam sterilization
- Cleaning: Cleaning in place (CIP, 2% NaOH, + 80 ° C, + 176 ° F), 3% H2O2, acids (HCl, H2SO4), max. 4-5%
- Calibration: 2-point calibration in an oxygen-free environment (nitrogen, sodium sulfite) and a second calibration value is optimal between 1% and 2% oxygen
- Shelf life when stored in the dark: 60 months
Specifications
Application area | Pharmaceuticals, Beverages |
Type | Portable |
Industry | Pharmaceutical, Food and Beverage |
Parameters | Dissolved oxygen, Oxygen |
Measurement Range | 0 - 5% O2 |
Compatibility | Oximeter Fibox 4 trace, Oximeter OXY-4 SMA |
Recommended products
Needle micro oxygen sensor NFSG-PSt7
The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.
SKU: NFSG-PSt7
Oxygen sensitive PET bottle cap OSC-PSt3
The oxygen sensitive PET bottle cap PreSens OSC-PSt3 is designed to measure oxygen penetration into opaque bottles in the range of 0 - 100% O2, 0 - 1000 hPa / 0 - 45 mg/L, 0 - 1400 μmol/L.
SKU: OSC-PSt3
Needle micro oxygen sensor NFSG-PSt8
The NFSG-PSt8 Fixed Tip Micro Needle Oxygen Sensor is designed for headspace measurement of trace oxygen or other applications where small volume measurements of gaseous oxygen are required. Has a measurement range from 0 to 10% oxygen with a detection limit of 0.007% O2.
SKU: NFSG-PSt8
Accessories
Polymer Optical Fiber for PreSens Measuring Instruments
Polymer optical fiber serves as a universal connector between the meter and the PreSens. POV with SMA connector is compatible with Fibox, OXY-1 SMA, OXY-1 WM, OXY mini and pH mini meters, as well as pCO2 mini. POF with ST connector is compatible with Microx 4 and OXY-1 ST series meters.
SKU: POF
Related products
Portable oxygen meter Fibox 4 trace
The Fibox 4 trace is a portable and fully self-contained optical oxygen meter for measuring O2 levels. Compatible with oxygen sensors ranging from 1 ppb to 100%
SKU: Fibox 4 trace
Portable oxygen meter Fibox 3 LCD trace v9
The PreSens Fibox 3 LCD Oxygen Meter is a compact, portable, easy-to-carry optical oximeter for stand-alone or PC-controlled use. The Oximeter can be used with normal, low and ultra-low O2 sensors.
SKU: Fibox 3 LCD trace v9
Multichannel oxygen meter OXY-4 SMA (G3)
The PreSens OXY 4 SMA multichannel oxygen meter can measure O2 in both liquid and gaseous phase, compatible with non-invasive sensors, immersion probes and flow cells type PSt3 (detection limit 15 ppb dissolved oxygen, 0 - 100% oxygen).
SKU: OXY-4 SMA (G3)
Show more
Recommended products
Needle micro oxygen sensor NFSG-PSt7
The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.
SKU: NFSG-PSt7
Oxygen sensitive PET bottle cap OSC-PSt3
The oxygen sensitive PET bottle cap PreSens OSC-PSt3 is designed to measure oxygen penetration into opaque bottles in the range of 0 - 100% O2, 0 - 1000 hPa / 0 - 45 mg/L, 0 - 1400 μmol/L.
SKU: OSC-PSt3
Needle micro oxygen sensor NFSG-PSt8
The NFSG-PSt8 Fixed Tip Micro Needle Oxygen Sensor is designed for headspace measurement of trace oxygen or other applications where small volume measurements of gaseous oxygen are required. Has a measurement range from 0 to 10% oxygen with a detection limit of 0.007% O2.
SKU: NFSG-PSt8