Self-adhesive optical point SP-PSt3-SA for oxygen sensor PreSens

SKU: SP-PSt3-SA
Manufacturer: РreSens
Availability: Order only
Optical point SP-PSt3-SA is a versatile and easy-to-use version of non-invasive oxygen sensors that allows oxygen measurements to be carried out non-contact and non-invasively from the outside through the vessel wall.
Designed for online oxygen monitoring in the range of 0 - 100%, 0 - 45 mg / l, and can be used to measure O2 in dissolved or gaseous phase.
Description Specifications Recommended products Accessories
Description
Description
Thanks to the new self-adhesive technology, the SP-PSt3-SA optical dots can be easily attached to almost any transparent glass or plastic container, making oxygen measurement and control even easier. Then, with the help of an oximeter, oxygen is measured non-contact and non-invasively from the outside - through the vessel wall.
SP-PSt3-SA optical points are extremely versatile and can be applied in a variety of industries, from biotech applications to quality control of packaged or bottled products.
Benefits of non-invasive oxygen measurement with the PreSens optical point
- Simplified integration with new self-adhesive technology
- Online monitoring without sampling
- Non-invasive measurements through the vessel wall
- Compatible with glass and almost all plastic containers
- Pre-calibrated and ready to use
SP-PSt3-SA Optical Point Specifications for PreSens Oximeter
- Measurement range:
Gaseous and dissolved O2: 0 - 100% O2, 0 - 1000 hPa
Dissolved O2: 0 - 45 mg / l, 0 - 1400 μmol / l - Detection limit:
Gaseous and dissolved O2: 0.03% oxygen
Dissolved O2: 15 ppb - Resolution:
Gaseous and dissolved O2:
± 0.01% O2 at 0.21% O2
± 0.1% O2 @ 20.9% O2
± 0.1 hPa at 2 hPa
± 1 hPa at 207 hPa
Dissolved O2:
± 0.004 mg / L at 0.091 mg / L
± 0.04 mg / L at 9.1 mg / L
± 0.14 μmol / L at 2.83 μmol / L
± 1.4 μmol / L at 283.1 μmol / L - Accuracy: ± 0.4% O2 @ 20.9% O2
± 0.05% O2 at 0.2% O2 - Drift: <0.03% O2 for 30 days (sampling interval 1 min / at 0% oxygen)
- Temperature measurement range: from 0 to + 50 ° С
- Response time (t90):
Gaseous and dissolved O2: less than 6 sec.
Dissolved O2: less than 40 sec. - Compatibility: aqueous solutions, methanol
- No transverse sensitivity with: pH 1 - 14, CO2, H2S, SO2, ionic forms
- Cross-sensitivity: organic solvents such as acetone, toluene, chloroform or methylene chloride, chlorine gas
- Sterilization: ethylene oxide (EtO), gamma irradiation
- Cleaning: cleaning in place (CIP, 2% NaOH, + 80 ° C, + 176 ° F), 3% H2O2, acids (HCl, H2SO4), max. 4-5%
- Calibration: two-point calibration in an oxygen-free environment (nitrogen, sodium sulfite) and an air-saturated environment
- Shelf life: 24 months when stored in the dark
Specifications
Application area | Pharmaceuticals, Food production, Beverages, Package control |
Type | Laboratory |
Industry | Pharmaceutical, Food and Beverage |
Parameters | Dissolved oxygen, Oxygen |
Measurement Range | 0 - 100% O2 |
Compatibility | Oximeter Fibox 4 trace, Oximeter OXY-1 SMA, Oximeter OXY-4 SMA |
Recommended products
Optical point SP-PSt3-NAU for oxygen sensor PreSens
The optical point is the most versatile version of the non-invasive optical oxygen sensors. SP-PSt3-NAU has a measuring range from 0 to 100% oxygen in dissolved or gas phase
SKU: SP-PSt3-NAU
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Optical point SP-PSt7-NAU for oxygen sensor PreSens
Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.
SKU: SP-PSt7-NAU, SP-PSt7-YAU
Accessories
Polymer Optical Fiber for PreSens Measuring Instruments
Polymer optical fiber serves as a universal connector between the meter and the PreSens. POV with SMA connector is compatible with Fibox, OXY-1 SMA, OXY-1 WM, OXY mini and pH mini meters, as well as pCO2 mini. POF with ST connector is compatible with Microx 4 and OXY-1 ST series meters.
SKU: POF
PreSens IS-SP Optical Point Integration Kit
The kit is specially designed for easy and convenient movement of PreSens optical points even in tall and hard-to-reach containers. It can be used to integrate PreSens self-adhesive points, such as SP-PSt3-SA, and SP-PSt3, SP-PSt6, SP-PSt9 optical points into containers, using liquid glue.
SKU: IS-SP
Related products
Portable oxygen meter Fibox 4 trace
The Fibox 4 trace is a portable and fully self-contained optical oxygen meter for measuring O2 levels. Compatible with oxygen sensors ranging from 1 ppb to 100%
SKU: Fibox 4 trace
Portable oxygen meter Fibox 3 LCD trace v9
The PreSens Fibox 3 LCD Oxygen Meter is a compact, portable, easy-to-carry optical oximeter for stand-alone or PC-controlled use. The Oximeter can be used with normal, low and ultra-low O2 sensors.
SKU: Fibox 3 LCD trace v9
Multichannel oxygen meter OXY-4 SMA (G3)
The PreSens OXY 4 SMA multichannel oxygen meter can measure O2 in both liquid and gaseous phase, compatible with non-invasive sensors, immersion probes and flow cells type PSt3 (detection limit 15 ppb dissolved oxygen, 0 - 100% oxygen).
SKU: OXY-4 SMA (G3)
Compact oxygen meter OXY-1 SMA
PreSens OXY-1 SMA is compatible with optical point type PSt3 and allows measurements of both gaseous and dissolved oxygen in the range of 0 -100% O2. Due to its small external dimensions, the oximeter can be installed almost anywhere.
SKU: OXY-1 SMA
Show more
Recommended products
Optical point SP-PSt3-NAU for oxygen sensor PreSens
The optical point is the most versatile version of the non-invasive optical oxygen sensors. SP-PSt3-NAU has a measuring range from 0 to 100% oxygen in dissolved or gas phase
SKU: SP-PSt3-NAU
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Optical point SP-PSt7-NAU for oxygen sensor PreSens
Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.
SKU: SP-PSt7-NAU, SP-PSt7-YAU