Optical point SP-PSt8-NAU for oxygen sensor PreSens



SKU: SP-PSt8-NAU, SP-PSt8-YAU
Manufacturer: РreSens
Availability: Order only
Optical points SP-PSt8-NAU and SP-PSt8-YAU allow carrying out the O2 change in the range from 0 to 10% with the boundary detection - 0.007%. Designed to work with PreSens oxygen sensors and oximeters: Microx 4, Microx 4 trace, OXY-1 ST, OXY-1 ST trace.
Advantages:
- Non-invasive measurements through the vessel wall
- Does not consume oxygen
- Signal independent of flow rate
- Accurate oxygen measurement in both liquid and gas phase
Description Specifications Video Recommended products Accessories
Description
Description
PreSens SP-PSt8-NAU and SP-PSt8-YAU optical points, when used with PreSens oximeters, allow accurate non-invasive oxygen measurements in the range from 0 to 10%, with a detection limit of 0.007%.
Due to their small size, these sensors are the most versatile and can be used in many applications for the measurement of dissolved and gaseous O2. For example, in the development of bioprocesses (monitoring oxygen in shake flasks), measurement of photosynthesis and cellular respiration of various organisms, bacteria, cell cultures, yeast or fungi.
Optical points are attached to the inner surface of any transparent or translucent container, then oxygen is measured from the outside - through the wall of the container.
SP-PSt8-NAU - not autoclavable.
SP-PSt8-YAU - autoclavable.
PreSens Optical Point Specifications
- Measurement range:
Gaseous and dissolved O2: 0 - 10% O2, 0 - 100 hPa
Dissolved O2: 0 - 4.5 mg / L, 0 - 140 μmol / L - Detection limit:
Gaseous and dissolved O2: 0.007% oxygen
Dissolved O2: 3 ppb - Permission:
Gaseous and Dissolved O2:
± 0.002% O2 @ 0.008% O2
± 0.06% O2 @ 2.5% O2
Dissolved O2:
± 0.7 ppb at 3 ppb
± 2.5 ppb at 1000 ppb - Accuracy at + 20 ° C: ± 3 ppb or ± 3% rel.
- Temperature measuring range: 0 - 50 ° C
- Response time (t90):
Gaseous and dissolved O2: Dissolved O2: - Compatibility: aqueous solutions, ethanol, methanol
- Not sensitive to: pH 1 - 14, CO2, H2S, SO2, ionic forms
- Sensitivity to: organic solvents such as acetone, toluene, chloroform or methylene chloride, chlorine gas
- Sterilization: Ethylene oxide (EtO) (steam sterilization is also available for SP-PSt8-YAU)
- Purification: 3% H2O2, ethanol, soap solution (for SP-PSt8-YAU also available CIP, 2% NaOH, + 80 ° C, + 176 ° F)
- Calibration: two-point calibration in an oxygen-free environment (nitrogen, sodium sulfite) and in an environment saturated with air
- Shelf life: 60 months when stored in the dark at room temperature
Various optical point models are available for ordering, depending on the diameter (3, 5, 7, 10 mm) and material: PTFE, USP Class VI (YOP), food safe (CAF).
For the SP-PSt8-NAU, in addition to the materials listed above, optical points with a fast response time, not autoclavable (OIW) are available.
Specifications
Application area | Environmental monitoring, Pharmaceuticals, Food production, Beverages |
Type | Portable |
Industry | Ecology, Pharmaceutical, Food and Beverage |
Parameters | Dissolved oxygen, Oxygen |
Measurement Range | 0 - 10% O2 |
Compatibility | Oximeter Microx 4 trace |
Recommended products
Optical point SP-PSt3-NAU for oxygen sensor PreSens
The optical point is the most versatile version of the non-invasive optical oxygen sensors. SP-PSt3-NAU has a measuring range from 0 to 100% oxygen in dissolved or gas phase
SKU: SP-PSt3-NAU
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Optical point SP-PSt7-NAU for oxygen sensor PreSens
Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.
SKU: SP-PSt7-NAU, SP-PSt7-YAU
Accessories
PreSens IS-SP Optical Point Integration Kit
The kit is specially designed for easy and convenient movement of PreSens optical points even in tall and hard-to-reach containers. It can be used to integrate PreSens self-adhesive points, such as SP-PSt3-SA, and SP-PSt3, SP-PSt6, SP-PSt9 optical points into containers, using liquid glue.
SKU: IS-SP
Related products
Microx 4 trace portable oxygen meter
PreSens Microx 4 trace is a compact, fully self-contained fiber optic oxygen meter for non-contact and microinvasive O2 measurements. Compatible with PSt7 sensors (detection limit 15 ppb, 0 - 100% oxygen) and also with PSt8 trace oxygen sensors (detection limit 3 ppb, 0 - 10% oxygen).
SKU: Microx 4 trace
Show more
Recommended products
Optical point SP-PSt3-NAU for oxygen sensor PreSens
The optical point is the most versatile version of the non-invasive optical oxygen sensors. SP-PSt3-NAU has a measuring range from 0 to 100% oxygen in dissolved or gas phase
SKU: SP-PSt3-NAU
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Optical point SP-PSt7-NAU for oxygen sensor PreSens
Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.
SKU: SP-PSt7-NAU, SP-PSt7-YAU