LCW053 Sulphide reagent set 0.1 - 2.0 mg/L S2-


SKU: LCW053
Manufacturer: Hach
Availability: In stock
LCW053 sulfide reagent kit.
Measurement range 0.01 - 2.0 mg / l S2-.
The number of tests per package is 25 - 49 depending on the number of samples / analyzes.
Storage temperature: 15-25 ° C (59-77 ° F).
Description Specifications Video Downloads Recommended products
Description
Description
LCW053 sulphide pre-dosed test kit from Hach. Compatible with DR series sprophotometers.
Applications: for wastewater analysis.
Method description: Dimethyl-p-phenylenediamine reacts with hydrogen sulphide to form an intermediate compound which turns into leucomethylene blue. The leucomethylene blue is oxidized to methylene blue by iron(III) ions
Conditions for analysis: The pH values of the water sample should be within the range of 3-10. The temperature of the water sample and reagents should be between 15–25 ° C (59–77 ° F).
Specifications
| Application area | Environmental monitoring, Test kits, Wastewater, Reagents, Treatment facilities, Laboratory analysis |
| Type | Cuvette tests 13 mm |
| Industry | Ecology, Pulp and paper, Transport, Chemical, Food and Beverage, Municipal |
| Parameters | Sulfide |
| Measurement Range | 0,01 - 2,0 mg/L S2- |
| Compatibility | DR6000, DR3900 |
| Method | DPD |
| Number of tests | 25-49 |
Recommended products
LCK325 Formaldehyde cuvette test 0,5 - 10 mg/L H2CO
LCK325 cuvette test for the determination of Formaldehyde, measuring range 0,5 - 10 mg/L H2CO.
SKU: LCK325
LCK328 Potassium cuvette test, 8 - 50 mg/L K
Potassium reagent kit, measuring range 8 - 50 mg / L K.
SKU: LCK328
LCS028 Silica acid (high range) reagent set 0,8 - 100 mg/L SiO2
LCS028 reagent kit for silicic acid and silicon, measuring range 0.8 - 100 mg / l SiO2 or 0.4 - 50 mg / l Si
SKU: LCS028
LCW032 Manganese reagent set 0.2-5 mg/L / 0.02-1.0 mg/L Mn
LCW032 reagent kit for the determination of manganese, measuring range 0.2 - 5 mg / l Mn and 0.02 - 1.0 mg / l Mn.
SKU: LCW032
LCK114 COD cuvette test, 150 - 1000 mg/L O
A set of reagents for the determination of COD; measuring range 150 - 1000 mg / L O2.
SKU: LCK114
LCK341 Nitrite cuvette test, 0,015 - 0,6 mg/L NO2-N
A set of reagents for the determination of nitrites, measuring range 0,015 - 0,6 mg/L NO2-N.
SKU: LCK341
LCI500 COD cuvette test, 0 - 150 mg/L O2
A set of reagents for the determination of COD; measuring range 0 - 150 mg/L O2.
SKU: LCI500
LCK318 Sludge activity (TTC) cuvette test
Test kit for determination of sludge activity, 5-200 µg Formazan (SA); 0 - 500% Residual Activity (RA).
SKU: LCK318
LCW250 Reducing agent for boiler water reagent set, 0,05 - 1,0 mg/L (DEHA)
LCW250 reagent set for the determination of reducing agents for boiler water. Measuring range 0,05 - 1,0 mg/L (DEHA)
SKU: LCW250
LYW185 Menthol in distillate cuvette test 0,5 - 15 mg Menthol/100 mL
Test kit for determination of menthol in distillate, range 0,5 - 15 mg menthol / 100 ml.
SKU: LYW185
LCW058 hydrogen peroxide pipette test, 1 - 10 g/L H2O2
LCW058 hydrogen peroxide test. Measurement range 1 - 10 g/L H2O2
SKU: LCW058
LCK549 Orthophosphate cuvette test, 0,01 - 0,5 mg/L PO4-P
Cuvette test for the determination of Orthophosphate, measuring range 0,01 - 0,5 mg/L PO4-P.
SKU: LCK549
LCK306 lead cuvette test 0,1 - 2,0 mg/L Pb
Test kit for determination of lead, measuring range 0.1 - 2.0 mg / l Pb.
SKU: LCK306
LCK330 Molybdenum cuvette test, 3 - 300 mg/L Mo
Reagent kit for the determination of Molybdenum, measuring range 3 - 300 mg/L Mo.
SKU: LCK330
LCK554 BOD5 cuvette test, 0,5 - 12,0 mg/L O2
A set of reagents for the determination of BOD5, measuring range 0,5 - 12,0 mg / L О2.
SKU: LCK554
LCW054 Sulphite test kit, 0,1 - 5,0 mg/L SO3
LCW054 test kit for the determination of Sulphites, measuring range 0,1 - 5,0 mg/L SO3.
SKU: LCW054
LCK1914 COD cuvette test for salt water, 70 - 700 mg/L O2
Reagent kit for the determination of COD in salt water. Measurement range 70 - 700 mg / l O2.
SKU: LCK1914
LCK348 Phosphate Ortho/Total cuvette test 0,5 - 5,0 mg/L PO4-P
Phosphate reagent kit (Ortho/Total), measuring range 0,5 - 5,0 mg/L PO4-P.
SKU: LCK348
LCK427 Residual Hardness cuvette test, 0,02 - 0,6 °dH (Ca+Mg)
LCK427 cuvette test for determination of residual hardness, measuring range 0,02 - 0,6 °dH.
SKU: LCK427
LCK386 TOC cuvette test (purging method) 30 - 300 mg/L C
Reagent kit for determination of total organic carbon (TOC); measuring range 30 - 300 mg/l C.
SKU: LCK386
LCK354 Silver cuvette test, 0,04 - 0,8 mg/L Ag
Test kit for the determination of silver, measuring range 0,04 - 0,8 mg/L Ag.
SKU: LCK354
LCK357 Starch cuvette test, 2 - 150 mg/L
LCK357 cuvette test for the determination of Starch, measuring range 2 - 150 mg/L
SKU: LCK357
LCK307 Boron cuvette test, 0,05 - 2,5 mg/L B
Boron test kit, measuring range 0,05 - 2,5 mg/L B.
SKU: LCK307
LCW021 Iron trace, reagent set, 0,005 - 2,0 mg/L Fe
Reagent kit for determination of iron traces, measuring range 0,005 - 0,25 mg/L Fe / 0,05 - 2,0 mg/L Fe.
SKU: LCW021
Recommended products
LCK653 Sulphide cuvette test, 0,1 - 2,0 mg/L S2-
Test kit for the determination of Sulphide, measuring range 0,1 - 2,0 mg/L S2-.
SKU: LCK653
LCW054 Sulphite test kit, 0,1 - 5,0 mg/L SO3
LCW054 test kit for the determination of Sulphites, measuring range 0,1 - 5,0 mg/L SO3.
SKU: LCW054
LCK304 Ammonium cuvette test, 0,015 - 2,0 mg/L NH4-N
Reagent kit LCK304 for the determination of Ammonium, measuring range 0,015 - 2,0 mg/L NH4-N / 0,02 - 2,5 mg/L NH4.
SKU: LCK304
LCK310 Chlorine (Cl2)/ Ozone (O3)/ Chlorine Dioxide (ClO2) cuvette test
Test kit for the determination of Chlorine (Cl2), Ozone (O3), Chlorine Dioxide (ClO2).
SKU: LCK310
LCK1414, COD cuvette test for samples with high Chloride loads 100 - 2000 mg/L O2
COD reagent kit for samples with high chloride content, measuring range 100 - 2000 mg / l O2.
SKU: LCK1014
LCK242 Vicinal diketones cuvette test, 0,015 - 0,5 mg/kg Diacetyl
LCK242 cuvette test for determination of vicinal diketones, measuring range 0,015 - 0,5 mg/kg Diacetyl.
SKU: LCK242
LCK346 Phenols cuvette test 5 - 150 mg/L
Test kit for phenols determination, measuring range 5 - 150 mg/L.
SKU: LCK346
LYW185 Menthol in distillate cuvette test 0,5 - 15 mg Menthol/100 mL
Test kit for determination of menthol in distillate, range 0,5 - 15 mg menthol / 100 ml.
SKU: LYW185
LCW632 Manganese reagent set 0,005 - 0,7 mg/L Mn
LCW632 reagent kit for the determination of manganese, measuring range 0.005 - 0.7 mg / l Mn.
SKU: LCW632