Replacement cap OEC30-PSt7-YAU with oxygen sensor for OXYPro WR and WRM probes

SKU: OEC30-PSt7-YAU
Manufacturer: РreSens
Availability: Order only
The beveled cap with built-in PSt7 sensor is specially designed to reduce air bubble formation when measuring dissolved oxygen with the OXYPro WR and WRM probes.
Maximum measuring range 0 - 100% O2 with detection limit 0.03% O2 / 20 ppb.
Description Specifications Recommended products
Description
Description
Replaceable cap with built-in sensor is available in different versions:
- OEC30-PSt7-YAU-YOP - USP Class VI compliant for bioprocess monitoring
- OEC30-PSt7-YAU-CAF - Food Safe
- OEC30-PSt7-YAU-PTFE - with hydrophobic teflon coating for measurements in aggressive media
It can withstand steam sterilization and CIP cleaning.
Benefits of OEC30-PSt7-YAU from PreSens
- Maximum measuring range 0 - 100% O2
- Reduced air bubble formation
- Various versions: USP Class VI compliant, food grade, corrosive environments
- Compatible with SIP (max. + 140 °C, 1.5 atm) and CIP (+ 80 °C, 2% NaOH)
- Easy replacement thanks to barcode calibration
- Pressure resistant
Specifications
- Measurement range: Optimal: 0 - 50 % O2, 0 - 500 hPa, 0 - 22.5 mg/L; Max.: 0 - 100 & O2, 0 - 1000 hPa, 0 - 45.0 mg/L
- Limit of detection: 0.03 % O2, 0.3 hPa, 0.015 mg/L
- Response time (t90):
OEC30-PSt7-YAU-YOP - Gaseous O2 < 10 sec.; Dissolved O2 < 30 sec.
OEC30-PSt7-YAU-CAF - Gaseous O2 < 15 sec.; Dissolved O2 < 40 sec.
OEC30-PSt7-YAU-PTFE - Gaseous O2 < 85 sec.; Dissolved O2 < 100 sec. - Compatibility: Aqueous solutions, ethanol, methanol
- No cross-sensitivity to: pH 1 - 14, CO2, H2S, SO2, ionic species
- Cross-sensitivity to: Chlorine gas; Organic solvents such as pure acetone, toluene, chloroform or methylene chloride
- Cleaning procedure: 3 % H2O2, acidic agents (HCl, H2SO4) max. 4 - 5 %; Cleaning agents containing ClO2 at room temperature
- Calibration: Two-point calibration in oxygen-free (e. g. nitrogen 5.0, 1 % sodium sulfite solution) and air-saturated environment (20.9 % oxygen, air-saturated water)
- Pressure resistance: 10 mbar up to 12 bar
- Temperature range operation: Optimal: 0 °C to + 50 °C; Max.: - 40 °C to + 90 °C
Specifications
| Application area | Environmental monitoring, Pharmaceuticals, Wastewater, Food production, Drinking water, Process control |
| Industry | Ecology, Pulp and paper, Pharmaceutical, Chemical, Food and Beverage, Municipal |
| Parameters | Dissolved oxygen |
| Measurement Range | 0 - 22.5 mg/L O2 |
| Operating temperature range | 0 - 50 °C |
Recommended products
Optical point SP-PSt8-NAU for oxygen sensor PreSens
Optical points SP-PSt8-NAU and SP-PSt8-YAU for PreSens oxygen sensors allow O2 measurement in the range from 0 to 10%, detection limit - 0.007%. SP-PSt8-NAU - not autoclavable. SP-PSt8-YAU - autoclavable.
SKU: SP-PSt8-NAU, SP-PSt8-YAU
Orbisphere K1200 Oxygen Sensor for nuclear applications, 0 - 40 ppm
Maintenance-free optical sensor for analysis and monitoring of dissolved oxygen in nuclear power plants.
SKU: K1200-S00H
Orbisphere M1100 inline oxygen sensor, 0 - 40 ppm, fitting 12 mm
Used in conjunction with Orbisphere controllers.
SKU: M1100-S10H
Laboratory dissolved oxygen sensor LDO101, cable 1 m, 3 m
Intellical LDO101 - a digital luminescent / optical sensor of dissolved oxygen (LDO technology).
SKU: LDO10101, LDO10103
Oxygen Probe for In-Line Measurement OIM-PSt3
PreSens OIM-PSt3 is designed for process control and provides accurate and stable O2 measurements in the 0-100% / 0-45 mg / L range, with a detection limit of 0.03% / 15 ppb.
SKU: OIM-PSt3
Oxygen sensitive PET bottle cap OSC-PSt6
The oxygen sensitive PET bottle cap PreSens OSC-PSt6 is designed to measure oxygen penetration in colored bottles in the range of 0 - 5% O2 / 0 - 2 mg/l.
SKU: OSC-PSt6
OXYBase WR-RS485 and WR-RS485M sensors for measuring gaseous and dissolved oxygen
OXYBase® WR-RS485 and WR-RS485M combine an optical sensor of the PSt3 type and an electro-optical module in one probe. The maximum measuring range is 0 - 100% O2 and the detection limit is 0.03% O2.
SKU: WR-RS485, WR-RS485M
SKU: 51344611
Optical point SP-PSt6-YAU for oxygen sensor PreSens
The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.
SKU: SP-PSt6-YAU
Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, 28 mm fitting
Used in conjunction with Orbisphere controllers.
SKU: M1100-S00
SKU: HD-960L
Replacement cap with oxygen sensor OEC-PSt7-NAU for OXYPro WR and WRM probes
Fast response oxygen sensor for PreSens OXYPro WR and WRM probes.
SKU: OEC-PSt7-NAU-OIW
SKU: HD-200FL
Orbisphere K1200 Oxygen Sensor for nuclear applications, 0 - 2000 ppb
Maintenance-free optical sensor for analysis and monitoring of dissolved oxygen in nuclear power plants.
SKU: K1200-S00
Replacement cap OEC30-PSt3-NAU for OXYBase WR oxygen probe
Replaceable oxygen sensor for fast response times and reduced air bubbles for OXYBase WR probes.
SKU: OEC30-PSt3-NAU-OIW
LDO 2 sc dissolved oxygen process sensor for seawater, cable 10 m
Hach LDO® Model 2 Probe with Luminescent Dissolved Oxygen Technology for seawater.
SKU: LXV416.99.20S01
SKU: OptiOx
Oxygen sensors WR, WRM and WR-ECS OXYPro series
Probe for measuring dissolved and gaseous oxygen.
SKU: WR, WRM, WR-ECS
Replacement oxygen sensor for OXYBase WR probes
The PreSens cap is made of stainless steel with an integrated PSt3 sensor.
SKU: OEC-PSt3-NAU
OXY-2GO Portable O2 Analyzer for Beer by Haffmans Pentair
The Pentair Haffmans Oxy-2Go is a portable analyzer designed specifically for small breweries that require an economical and reliable solution for monitoring dissolved oxygen (DO). It provides accurate measurement of the full range of oxygen in wort, beer and other carbonated beverages using proven Pentair Haffmans optical technology.
SKU: OXY-2GO
Needle micro oxygen sensor NFSG-PSt7
The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.
SKU: NFSG-PSt7
Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm
Used in conjunction with Orbisphere controllers.
SKU: M1100-S10
Needle micro oxygen sensor NFSG-PSt8
The NFSG-PSt8 Fixed Tip Micro Needle Oxygen Sensor is designed for headspace measurement of trace oxygen or other applications where small volume measurements of gaseous oxygen are required. Has a measurement range from 0 to 10% oxygen with a detection limit of 0.007% O2.
SKU: NFSG-PSt8
Optical point SP-PSt9 for oxygen sensor PreSens
Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.
SKU: SP-PSt9-NAU-D3-OIW
Recommended products
Oxygen sensitive PET bottle cap OSC-PSt6
The oxygen sensitive PET bottle cap PreSens OSC-PSt6 is designed to measure oxygen penetration in colored bottles in the range of 0 - 5% O2 / 0 - 2 mg/l.
SKU: OSC-PSt6
Orbisphere M1100 inline oxygen sensor, 0 - 40 ppm, fitting 28 mm
Used in conjunction with Orbisphere controllers.
SKU: M1100-S00H
OXYBase WR-RS485 and WR-RS485M sensors for measuring gaseous and dissolved oxygen
OXYBase® WR-RS485 and WR-RS485M combine an optical sensor of the PSt3 type and an electro-optical module in one probe. The maximum measuring range is 0 - 100% O2 and the detection limit is 0.03% O2.
SKU: WR-RS485, WR-RS485M
Oxygen sensors WR, WRM and WR-ECS OXYPro series
Probe for measuring dissolved and gaseous oxygen.
SKU: WR, WRM, WR-ECS
Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm
Used in conjunction with Orbisphere controllers.
SKU: M1100-S10
LDO 2 sc dissolved oxygen process sensor for seawater, cable 10 m
Hach LDO® Model 2 Probe with Luminescent Dissolved Oxygen Technology for seawater.
SKU: LXV416.99.20S01
Field dissolved oxygen sensor LDO101, cable 5, 10, 15, 30 m
Intellical LDO101 is a digital luminescent / optical dissolved oxygen sensor (LDO technology). Luminescence based LDO technology - no electrolyte change required, no interference due to deposits or hydrogen sulfide.
SKU: LDO10105, LDO10110
SKU: OXI
Dissolved oxygen sensor Intellical LBOD101 for BOD measurement
Luminescent / optical dissolved oxygen (LDO) sensor for BOD measurement, 1 m cable.
SKU: LBOD10101