Replacement cap OEC30-PSt3-NAU for OXYBase WR oxygen probe

presens-oec30-pst3-nau-oiw-smennyj-kolpachok-oxybase-wr.jpeg

SKU: OEC30-PSt3-NAU-OIW

Manufacturer: РreSens

Availability: Order only

Order Add to comparison

Replacement cap OEC30-PSt3-NAU-OIW from PreSens provides fast response times and reduced air bubbles for OXYBase® WR probes.

  • Maximum measuring range 0 - 100% O2
  • Reduced air bubble formation
  • Fast response time
  • Easy replacement
  • Pressure resistant

Description

Description

The wide range PSt3 sensor is built into a beveled stainless steel cap. This cap reduces air bubble formation on the sensor with very fast response times.

The maximum measuring range is 0 to 100% O2 (detection limit 0.03% O2 / 20 ppb). The OEC30-PSt3-NAU screws onto the OXYBase WR housing to replace a used sensor and can be calibrated with one quick scan of the barcode. This cap cannot be autoclaved.

  • Measurement range: Optimal: 0 - 50 % O2, 0 - 500 hPa, 0 - 22.5 mg/L; Max.: 0 - 100 % O2, 0 - 1000 hPa, 0 - 45.0 mg/L
  • Limit of detection: 0.03 % O2, 0.3 hPa, 0.020 mg/L
  • Compatibility: Aqueous solutions, ethanol, methanol
  • No cross-sensitivity to: pH 1 - 14, CO2, H2S, SO2, ionic species
  • Cross-sensitivity to: Chlorine gas, Organic solvents such as pure acetone, toluene, chloroform or methylene chloride
  • Cleaning procedure: 3 % H2O2, acidic agents (HCl, H2SO4) max. 4 - 5 %, Cleaning agents containing ClO2 at room temperature
  • Calibration: Two-point calibration in oxygen-free (e. g. nitrogen 5.0, 1 % sodium sulfite solution) and air-saturated environment (20.9 % oxygen, air-saturated water)
  • Storage stability: 5 years provided the sensor material is stored at room temperature in dry conditions and in the dark
  • Pressure resistance: 3 bar
  • Temperature range operation: Optimal: 0 °C to + 40 °C / Max.: - 10 °C to + 90 °C
  • Temperature range storage: Optimal: room temperature (+ 20 °C ± 5 °C) / Max.: 0 °C to + 70 °C
Specifications

Specifications

Application areaEnvironmental monitoring, Wastewater, Food production
IndustryEcology, Municipal
ParametersDissolved oxygen
Measurement Range0 - 22.5 mg/L O2
Operating temperature range0 - 40 °C
Recommended products

Recommended products

SKU: 92222102

View product Compare

Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, 28 mm fitting

Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, 28 mm fitting

Used in conjunction with Orbisphere controllers.

SKU: M1100-S00

View product Compare

Replacement oxygen sensor for OXYBase WR probes

Replacement oxygen sensor for OXYBase WR probes

The PreSens cap is made of stainless steel with an integrated PSt3 sensor.

SKU: OEC-PSt3-NAU

View product Compare

Optical point SP-PSt6-YAU for oxygen sensor PreSens

Optical point SP-PSt6-YAU for oxygen sensor PreSens

The optical point is the most versatile version of optical oxygen sensors. Dissolved and gaseous oxygen is measured in a non-contact way through the transparent wall of the container. SP-PSt6-YAU has a measuring range of 0 to 5% oxygen in dissolved or gas phase.

SKU: SP-PSt6-YAU

View product Compare

Oxygen sensitive PET bottle cap OSC-PSt6

Oxygen sensitive PET bottle cap OSC-PSt6

The oxygen sensitive PET bottle cap PreSens OSC-PSt6 is designed to measure oxygen penetration in colored bottles in the range of 0 - 5% O2 / 0 - 2 mg/l.

SKU: OSC-PSt6

View product Compare

Replacement cap with oxygen sensor OEC-PSt7-NAU for OXYPro WR and WRM probes

Replacement cap with oxygen sensor OEC-PSt7-NAU for OXYPro WR and WRM probes

Fast response oxygen sensor for PreSens OXYPro WR and WRM probes.

SKU: OEC-PSt7-NAU-OIW

View product Compare

SKU: 51344611

View product Compare

Needle micro oxygen sensor NFSG-PSt7

Needle micro oxygen sensor NFSG-PSt7

The NFSG-PSt7 Fixed Tip Micro Needle Oxygen Sensor has a measuring range from 0 to 100% oxygen with a detection limit of 0.03% oxygen. Designed for headspace measurement in packaging or other applications where small volume measurements of gaseous oxygen are required.

SKU: NFSG-PSt7

View product Compare

SKU: OptiOx

View product Compare

LDO sc process dissolved oxygen sensor; cable 10 meters

LDO sc process dissolved oxygen sensor; cable 10 meters

LDO Process Dissolved Oxygen Sensor for SC Series Online Controllers. Available with 10 meter cable.

SKU: LXV416.99.20001

View product Compare

Optical point SP-PSt7-NAU for oxygen sensor PreSens

Optical point SP-PSt7-NAU for oxygen sensor PreSens

Optical points SP-PSt7-NAU and SP-PSt7-YAU for PreSens oxygen sensors allow O2 measurements from 0 to 100% with a detection limit of 0.03%. SP-PSt7-NAU - not autoclavable. SP-PSt7-YAU - autoclavable.

SKU: SP-PSt7-NAU, SP-PSt7-YAU

View product Compare

SKU: HD-200FL

View product Compare

SKU: 30298424

View product Compare

Field dissolved oxygen sensor LDO101, cable 5, 10, 15, 30 m

Field dissolved oxygen sensor LDO101, cable 5, 10, 15, 30 m

Intellical LDO101 is a digital luminescent / optical dissolved oxygen sensor (LDO technology). Luminescence based LDO technology - no electrolyte change required, no interference due to deposits or hydrogen sulfide.

SKU: LDO10105, LDO10110

View product Compare

Laboratory dissolved oxygen sensor LDO101, cable 1 m, 3 m

Laboratory dissolved oxygen sensor LDO101, cable 1 m, 3 m

Intellical LDO101 - a digital luminescent / optical sensor of dissolved oxygen (LDO technology).

SKU: LDO10101, LDO10103

View product Compare

SKU: 114.000

View product Compare

Oxygen Probe for In-Line Measurement OIM-PSt6

Oxygen Probe for In-Line Measurement OIM-PSt6

PreSens OIM-PSt6 is designed for process control and provides accurate and stable O2 measurements in the 0-5% / 0-2 mg/L range, with a detection limit of 0.002% / 1 ppb.

SKU: OIM-PSt6

View product Compare

Orbisphere K1200 Oxygen Sensor for nuclear applications, 0 - 40 ppm

Orbisphere K1200 Oxygen Sensor for nuclear applications, 0 - 40 ppm

Maintenance-free optical sensor for analysis and monitoring of dissolved oxygen in nuclear power plants.

SKU: K1200-S00H

View product Compare

Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm

Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm

Used in conjunction with Orbisphere controllers.

SKU: M1100-S10

View product Compare

Replacement cap OEC30-PSt7-NAU-OIW with oxygen sensor for OXYPro WR and WRM probes

Replacement cap OEC30-PSt7-NAU-OIW with oxygen sensor for OXYPro WR and WRM probes

The wide range PSt7 sensor is built into a beveled stainless steel cap. The design reduces the formation of air bubbles on the sensor with a very fast response time (< 3 sec.).

SKU: OEC30-PSt7-NAU-OIW

View product Compare

LDO 2 sc dissolved oxygen process sensor for seawater, cable 10 m

LDO 2 sc dissolved oxygen process sensor for seawater, cable 10 m

Hach LDO® Model 2 Probe with Luminescent Dissolved Oxygen Technology for seawater.

SKU: LXV416.99.20S01

View product Compare

OXY-2GO Portable O2 Analyzer for Beer by Haffmans Pentair

OXY-2GO Portable O2 Analyzer for Beer by Haffmans Pentair

The Pentair Haffmans Oxy-2Go is a portable analyzer designed specifically for small breweries that require an economical and reliable solution for monitoring dissolved oxygen (DO). It provides accurate measurement of the full range of oxygen in wort, beer and other carbonated beverages using proven Pentair Haffmans optical technology.

SKU: OXY-2GO

View product Compare

OXYBase WR-RS485 and WR-RS485M sensors for measuring gaseous and dissolved oxygen

OXYBase WR-RS485 and WR-RS485M sensors for measuring gaseous and dissolved oxygen

OXYBase® WR-RS485 and WR-RS485M combine an optical sensor of the PSt3 type and an electro-optical module in one probe. The maximum measuring range is 0 - 100% O2 and the detection limit is 0.03% O2.

SKU: WR-RS485, WR-RS485M

View product Compare

Optical point SP-PSt9 for oxygen sensor PreSens

Optical point SP-PSt9 for oxygen sensor PreSens

Optical point SP-PSt9 for non-invasive measurement of ultra-low oxygen content in the range of 0 - 200 ppmv O2, with a detection limit of 0.5 ppmv oxygen.

SKU: SP-PSt9-NAU-D3-OIW

View product Compare

Recommended products