Optical point for M1100 and K1100 dissolved oxygen sensors
SKU: M1100-L, M1100-H
Manufacturer: Orbisphere
Availability: In stock
Dedicated optical contact pad (sensing element) for the Orbisphere M1100 and K1100 dissolved oxygen sensors:
- M1100-L low measuring range 0 - 2000 ppb
- M1100-H high measuring range 0 - 40 ppm
Scope of delivery: optical point and O-ring.
Description Specifications Recommended products
Description
Description
The optical point must be replaced about once a year. It is recommended to calibrate the sensor every 6 months if used in the beverage industry using CIP. The procedure is very simple and takes no more than a couple of minutes. Depending on the oxygen measuring range, the sensor life may be shortened and the frequency of maintenance and calibration may increase. If bleaching compounds and strong oxidants (such as ClO2) are present in the sample, sensor life may also be shortened.
Removing the optical point (sensitive element)
- Slide the maintenance tool (straight edges on top) as far as possible over the old optical point. Continue to push and twist the tool until the straight edges of the tool fit into the straight grooves on the sensor.
- When the instrument is in the desired position, turn it counterclockwise to unscrew the old optical point.
- After unscrewing it completely, simply remove it. Remove the tool for maintenance and discard the old optical point of the sensor.
Note: check the o-ring. If it is damaged, remove it with tweezers and replace with a new one from the maintenance kit.
Optical point replacement
Important: During the replacement process, avoid scratching or damaging the sensor (black surface on the sensor head).
- Slide the maintenance tool (straight edges on top) as far as possible over the new optical point. Continue to push and twist the tool until the straight edges of the tool fit into the straight grooves on the sensor
- Make sure the sensor collar is as far down as it will go, so that the top of the collar is aligned with the base of the sensor head.
- Take the combined maintenance tool and sensor spot and place it in the end of the sensor.
- Turn the tool clockwise to screw in the optical point. Do not over tighten. Once securely in place, remove the service tool.
Specifications
Application area | Brewing, Beverages, Process control |
Type | Industrial |
Industry | Food and Beverage |
Parameters | Dissolved oxygen |
Recommended products
2084900 Glass cell for laboratory turbidity meters, 30 ml, 6 pcs. with caps
Glass cuvette for samples. Used for turbidimeters 2100N, 2100AN and Lab RATIO.
SKU: 2084900
White caps for Culture Tube
The Hach screw cap uses a durable seal to ensure the vial is tight.
SKU: 2275800, 2241106
Rectangular sample cells, 10 mm, polystyrene, 4.5 ml
Sample cuvettes, rectangular, 1 cm, polystyrene, 4.5 ml, optical path length 10 mm.
SKU: 2743400
Cuvette Hach round 1 inch (25 mm), 6 pcs. 10 mL each
Sample Cell. Use with Hach colorimeters and spectrophotometers.
SKU: 2427606
Glass square sample cell 25 mm, matched pair
Accessory for spectrophotometers / spectral analysis of liquids.
SKU: 2095000
Set for the preparation of dilution water for BOD 5 test
Set for BOD5 cuvette test.
SKU: LZC901
Plastic tubes with caps, 4 pieces
Tubes for colorimetric analysis of water.
SKU: 4660004
Sunroof visor for SC4200c and SC4500 controllers
Visor for controllers protection from changes in weather conditions.
SKU: LXZ524.99.00033
Rectangular plastic cuvette, 10 mm; 100 pieces
Disposable 1.5 ml cuvettes; packing of 100 pieces.
SKU: 2629500
Digital Sight 1000 camera for Nikon ECLIPSE microscopes
The Digital Sight 1000 is a cost-effective color camera that can directly display high-definition microscope images on a Full HD display without the need for a PC.
SKU: Digital Sight 1000
Replacement sensor for CLT10 sc analyzer
Replacement sensor for CLT10 sc total chlorine analyzer. Stainless steel tip.
SKU: 8628900
Glass cuvette Hach square 1 inch (25 mm), 2 pcs.
Photometric vials. For use with Hach DR1900, DR6000, DR3900 spectrophotometers.
SKU: 2495402, 2495408
Amtax sc analyzer electrode maintenance kit
The kit contains 3 bottles of electrolyte and 3 membranes for the AMTAX sc ammonium analyzer for ranges 2, 3, 4 (0.05 - 1000 mg/L NH4-N).
SKU: LCW868
Hach rectangular cuvettes 50 mm, 10 pcs. PMMA
Sample cuvette, polystyrene, 50 x 10 mm, optical path 50 mm, minimum volume 5.0 ml, with lids, pack contains 10 pcs.
SKU: LZP341
UV protection shield for SC4200c and SC4500 controllers
Sun protection panel for SC controllers.
SKU: LXZ524.99.00004
Compact Extension Cables Аber Instruments
Aber Instruments are recognized by many of the world's largest brewing companies as the most accurate and reliable instruments for measuring viable yeast cell concentration.
SKU: 1635-24/1
Crimp caps with pre-installed septa for vials, 20 mm
20 mm aluminum crimp caps for chromatography vials with pre-installed septa.
SKU: #20PTFE/White Silicone
Deuterium Lamp
Deuterium (UV) lamp. Suitable for use with Hach DR5000, DR6000 spectrophotometers.
SKU: A23792
Peristaltic pump ZEUTEC
The ZEUTEC pump is used in conjunction with a liquid analysis drawer for SpectraAlyzer 2.0 analyzers. Due to its small size, the pump can be placed on a bench next to the analyzer or on the instrument itself for easy access.
SKU: 104-A100-1
Glass cuvette for samples 25 mm., 6 pieces with caps
Sample cuvette. For use with Hach DR900 colorimeter.
SKU: 2401906
Color comparator box
Color comparator box for use with Hach color discs.
SKU: 173200
Service kit 19-KIT-130 for BioTector 3500e
Replacement set for maintenance, interval 6 months.
SKU: 19-KIT-130
AutoSampler 2.0 for ZEUTEC SpectraAlyzer analyzers
The ZEUTEC AutoSampler 2.0 is used in conjunction with the liquid analysis compartment (Liquid Drawer) of the SpectraAlyzer analyzer. Simplifies compositional analysis of samples using near infrared reflectance characteristics.
SKU: 103-A100-1
Adapter A for DR3900 Spectrophotometer
Replacement adapter for sample cells.
SKU: LZV846
Related products
Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm
Used in conjunction with Orbisphere controllers.
SKU: M1100-S10
Orbisphere M1100 inline oxygen sensor, 0 - 40 ppm, fitting 28 mm
Used in conjunction with Orbisphere controllers.
SKU: M1100-S00H
Inline oxygen sensor Orbisphere K1100 series, 0 - 2000 ppb, 28 mm fitting
The Orbisphere K1100 is a high-precision, fluorescent dissolved oxygen sensor optimized for energy applications.
SKU: K1100-S00
Inline oxygen sensor Orbisphere K1100 series, 0 - 40 ppm, 28 mm fitting
The Orbisphere K1100-S00H is a high-precision, fluorescent dissolved oxygen sensor optimized for energy applications.
SKU: K1100-S00H
Show more
Recommended products
Replacement cartridge for AN-ISE sc, A-ISE sc and N-ISE sc probes
Cartridge for process Hach Lange ion-selective sensors for the determination of ammonium and nitrates.
SKU: LZY694
Delivery tubes for Digital Titrator, 5 pk
Delivery tubes for Hach Handheld Digital Titrator (1690001).
SKU: 1720500
Quartz square sample cell, 10 mm
Quartz glass sample cuvette, 10 x 10 mm, path length 10 mm, volume = 3.5 ml. Supplied with caps, matched pair or 1 piece.
SKU: 2624410, 4822800
Glass cuvette Hach square 1 inch (25 mm), 2 pcs.
Photometric vials. For use with Hach DR1900, DR6000, DR3900 spectrophotometers.
SKU: 2495402, 2495408
Sunroof visor for SC4200c and SC4500 controllers
Visor for controllers protection from changes in weather conditions.
SKU: LXZ524.99.00033
Hach rectangular cuvettes 50 mm, 10 pcs. PMMA
Sample cuvette, polystyrene, 50 x 10 mm, optical path 50 mm, minimum volume 5.0 ml, with lids, pack contains 10 pcs.
SKU: LZP341
Pocket Pro+ Replacement sensor for Multi parameter tester 2
For Pocket Pro+ Multi parameter tester 2 only.
SKU: 9532801
BODTrak II Reagent Kit with BOD Bottles
Replacement kit of reagents and bottles for BOD determination.
SKU: 2952440
Rectangular sample cells, 10 mm, polystyrene, 4.5 ml
Sample cuvettes, rectangular, 1 cm, polystyrene, 4.5 ml, optical path length 10 mm.
SKU: 2743400