Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

Optical point for M1100 and K1100 dissolved oxygen sensors

orbisphere-m1100-l-opticheskaya-tochka.jpg

SKU: M1100-L, M1100-H

Manufacturer: Orbisphere

Availability: In stock

Order Add to comparison

Dedicated optical contact pad (sensing element) for the Orbisphere M1100 and K1100 dissolved oxygen sensors:

  • M1100-L low measuring range 0 - 2000 ppb
  • M1100-H high measuring range 0 - 40 ppm

Scope of delivery: optical point and O-ring.


Description

Description

The optical point must be replaced about once a year. It is recommended to calibrate the sensor every 6 months if used in the beverage industry using CIP. The procedure is very simple and takes no more than a couple of minutes. Depending on the oxygen measuring range, the sensor life may be shortened and the frequency of maintenance and calibration may increase. If bleaching compounds and strong oxidants (such as ClO2) are present in the sample, sensor life may also be shortened.

Removing the optical point (sensitive element)

how to remove optical spot

  1. Slide the maintenance tool (straight edges on top) as far as possible over the old optical point. Continue to push and twist the tool until the straight edges of the tool fit into the straight grooves on the sensor.
  2. When the instrument is in the desired position, turn it counterclockwise to unscrew the old optical point.
  3. After unscrewing it completely, simply remove it. Remove the tool for maintenance and discard the old optical point of the sensor.

Note: check the o-ring. If it is damaged, remove it with tweezers and replace with a new one from the maintenance kit.

Optical point replacement

how to replace optical point

Important: During the replacement process, avoid scratching or damaging the sensor (black surface on the sensor head).

  1. Slide the maintenance tool (straight edges on top) as far as possible over the new optical point. Continue to push and twist the tool until the straight edges of the tool fit into the straight grooves on the sensor
  2. Make sure the sensor collar is as far down as it will go, so that the top of the collar is aligned with the base of the sensor head.
  3. Take the combined maintenance tool and sensor spot and place it in the end of the sensor.
  4. Turn the tool clockwise to screw in the optical point. Do not over tighten. Once securely in place, remove the service tool.
Specifications

Specifications

Application areaBrewing, Beverages, Process control
TypeIndustrial
IndustryFood and Beverage
ParametersDissolved oxygen
Recommended products

Recommended products

SKU: 006.963

View product Compare

Replacement sensor for ORP meter Pocket Pro+

Replacement sensor for ORP meter Pocket Pro+

For Pocket Pro + testers only

SKU: 9532101

View product Compare

Glass cuvette Hach square 1 inch (25 mm), 2 pcs.

Glass cuvette Hach square 1 inch (25 mm), 2 pcs.

Photometric vials. For use with Hach DR1900, DR6000, DR3900 spectrophotometers.

SKU: 2495402, 2495408

View product Compare

Replacement sensor for CLT10 sc analyzer

Replacement sensor for CLT10 sc analyzer

Replacement sensor for CLT10 sc total chlorine analyzer. Stainless steel tip.

SKU: 8628900

View product Compare

BODTrak II Reagent Kit with BOD Bottles

BODTrak II Reagent Kit with BOD Bottles

Replacement kit of reagents and bottles for BOD determination.

SKU: 2952440

View product Compare

AutoSampler 2.0 for ZEUTEC SpectraAlyzer analyzers

AutoSampler 2.0 for ZEUTEC SpectraAlyzer analyzers

The ZEUTEC AutoSampler 2.0 is used in conjunction with the liquid analysis compartment (Liquid Drawer) of the SpectraAlyzer analyzer. Simplifies compositional analysis of samples using near infrared reflectance characteristics.

SKU: 103-A100-1

View product Compare

Deuterium Lamp

Deuterium Lamp

Deuterium (UV) lamp. Suitable for use with Hach DR5000, DR6000 spectrophotometers.

SKU: A23792

View product Compare

Vials for chromatography, 10 and 20 ml

Vials for chromatography, 10 and 20 ml

Vials for headspace analysis. They are an analogue of a wide range of brands such as Agilent, Gerstel, etc.

SKU: #18Headspace vial

View product Compare

2084900 Glass cell for laboratory turbidity meters, 30 ml, 6 pcs. with caps

2084900 Glass cell for laboratory turbidity meters, 30 ml, 6 pcs. with caps

Glass cuvette for samples. Used for turbidimeters 2100N, 2100AN and Lab RATIO.

SKU: 2084900

View product Compare

Delivery tubes for Digital Titrator, 5 pk

Delivery tubes for Digital Titrator, 5 pk

Delivery tubes for Hach Handheld Digital Titrator (1690001).

SKU: 1720500

View product Compare

SKU: 12-0308

View product Compare

SKU: 005.094

View product Compare

Service kit for BioTector 3500 19-KIT-123

Service kit for BioTector 3500 19-KIT-123

Replacement set for maintenance, interval 6 months.

SKU: 19-KIT-123

View product Compare

Hach rectangular cuvettes 50 mm, 10 pcs. PMMA

Hach rectangular cuvettes 50 mm, 10 pcs. PMMA

Sample cuvette, polystyrene, 50 x 10 mm, optical path 50 mm, minimum volume 5.0 ml, with lids, pack contains 10 pcs.

SKU: LZP341

View product Compare

SKU: 006.593

View product Compare

Two-layer silicone septa 17.5 mm

Two-layer silicone septa 17.5 mm

17.5 mm PTFE/silicone septa, compatible with 18 mm screw caps and 10 ml and 20 ml chromatography vials. Work on Agilent instruments, CTC PAL, etc.

SKU: #17,5Siiicone

View product Compare

Cl17 Chlorine Analyzer Maintenance Kit

Cl17 Chlorine Analyzer Maintenance Kit

Pre-assembled tubing for annual maintenance of the Hach CL17 chlorine analyzer.

SKU: 5444301, 4721600

View product Compare

Adapter A for DR3900 Spectrophotometer

Adapter A for DR3900 Spectrophotometer

Replacement adapter for sample cells.

SKU: LZV846

View product Compare

SKU: 1601-0020

View product Compare

Replacement cuvette for turbidity meters TU5300sc and TU5400sc

Replacement cuvette for turbidity meters TU5300sc and TU5400sc

High quality glass test vial.

SKU: LZY834

View product Compare

White caps for Culture Tube

White caps for Culture Tube

The Hach screw cap uses a durable seal to ensure the vial is tight.

SKU: 2275800, 2241106

View product Compare

Compact Extension Cables Аber Instruments

Compact Extension Cables Аber Instruments

Aber Instruments are recognized by many of the world's largest brewing companies as the most accurate and reliable instruments for measuring viable yeast cell concentration.

SKU: 1635-24/1

View product Compare

SKU: 1.14944.0001

View product Compare

Amtax sc analyzer electrode maintenance kit

Amtax sc analyzer electrode maintenance kit

The kit contains 3 bottles of electrolyte and 3 membranes for the AMTAX sc ammonium analyzer for ranges 2, 3, 4 (0.05 - 1000 mg/L NH4-N).

SKU: LCW868

View product Compare

Related products

Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm

Orbisphere M1100 inline oxygen sensor, 0 - 2 ppm, fitting 12 mm

Used in conjunction with Orbisphere controllers.

SKU: M1100-S10

View product Compare

Orbisphere M1100 inline oxygen sensor, 0 - 40 ppm, fitting 28 mm

Orbisphere M1100 inline oxygen sensor, 0 - 40 ppm, fitting 28 mm

Used in conjunction with Orbisphere controllers.

SKU: M1100-S00H

View product Compare

Inline oxygen sensor Orbisphere K1100 series, 0 - 2000 ppb, 28 mm fitting

Inline oxygen sensor Orbisphere K1100 series, 0 - 2000 ppb, 28 mm fitting

The Orbisphere K1100 is a high-precision, fluorescent dissolved oxygen sensor optimized for energy applications.

SKU: K1100-S00

View product Compare

Inline oxygen sensor Orbisphere K1100 series, 0 - 40 ppm, 28 mm fitting

Inline oxygen sensor Orbisphere K1100 series, 0 - 40 ppm, 28 mm fitting

The Orbisphere K1100-S00H is a high-precision, fluorescent dissolved oxygen sensor optimized for energy applications.

SKU: K1100-S00H