LeadTrak™ Reagent Set, Fast Column Extraction Method

SKU: 2375000
Manufacturer: Hach
Availability: Order only
Lead reagent kit for LeadTrak ™ Fast Column Extraction. The acid-soluble lead in the drinking water sample is first concentrated in the Fast Column Extractor. The lead is then eluted from the extractor and determined colorimetrically using an indicator.
Hach Method 8317.
Range: 5 - 150 μg/L Pb.
Sample size: 100 ml.
The kit is enough to carry out 20 tests.
Description Specifications Downloads Recommended products
Description
Description
Reagent Hach 2375000.
Parameter: Lead
Range: 5 - 150 μg / L Pb
Applications: For drinking water
Method description: Acid-soluble lead, such as Pb2 +, in a drinking water sample is first concentrated in the Fast Column Extractor. The lead is then eluted from the extractor and determined colorimetrically using an indicator. Test results are measured at 477 nm.
Specifications
| Application area | Reagents, Food production, Drinking water, Brewing, Beverages |
| Type | Liquid reagents |
| Industry | Power generation, Transport, Chemical, Food and Beverage |
| Parameters | Plumbum |
| Measurement Range | 5 - 150 μg/L Pb |
| Compatibility | DR6000, DR1900, DR3900, DR5000, DR2800, DR3800 |
| Method | LeadTrak |
| Number of tests | 20 |
| Quality control | 1426210 |
Recommended products
DPD 1 reagent solution (Lovibond), green bottle
Reagent for determining the concentration of total/free chlorine in water.
SKU: 471020, 471026, 471021
SKU: 238934
Powder Pillows copper sulfate solution
Reagent for distillation of phenol.
SKU: 1481866
SKU: 1.04201.0100
Nitrification inhibitor for BOD, Trichloromethyl Pyridine (TCMP)
The BOD of carbonaceous compounds (CBOD) can be determined by adding a nitrification inhibitor. The CBOD test is recommended for biologically treated wastewater, biologically treated wastewater and river water samples.
SKU: 253335
SKU: 199526
SKU: 193432
CL17sc analyzer optics cleaning solution
The set contains sulfuric acid (100 ml dropper bottle) and cotton swabs (10).
SKU: 8573100
Reagent kit Amtax sc with standard, for range 0.05-20.0 mg/L NH4-N
LCW865 Reagent Kit for Oline Ammonium Analyzer with Standard Calibration Solutions.
SKU: LCW865
SKU: 1.16754.5000
Cyclohexanone solution, 100 mL
The solution is used in the determination of zinc.
SKU: 1403332
SKU: 223632
PHOSPHAX sc LR analyzer cleaning solution C
LCW959 solution for online process low range orthophosphate analyzer.
SKU: LCW959
SKU: 2257249
Hardness reagent kit, 4 - 1000 μg/L CaCO3
Determination of ultra-low level of water hardness by the chlorophosphonazo method.
SKU: 2603101
Reagent set for the total hardness test kit HA-71A
Replacement reagent kit for determination of total hardness by drop count titration with EDTA using the HA-71A test kit.
SKU: 2437800
181732 Sulfide 2 Reagent, 100 ml
For the determination of sulfide 5-800 µg/l S2-. Convenient dropper bottle.
SKU: 181732
Nitrogen-Ammonia Reagent Set, Nessler, 0.02-2.50 mg/L NH3-N
Hach reagents for the determination of a Nitrogen-Ammonia by the Nessler method in the analysis of drinking, waste and process water, as well as for control and monitoring of product quality. The reagent volume is sufficient for approximately 250 tests. Range 0.02-2.50 mg / L NH3-N.
SKU: 2458200
Reagent B for Phosphax sc LR Analyzer
Reagent for Hach Lange Low Range Orthophosphate Analyzer.
SKU: LCW957
Silica Reagent Set, Bulk Solution, 3 - 1000 µg/L SiO2
Hach reagent kit for the determination of silicon dioxide in the ultra-low range 3 - 1000 μg / l SiO2. The kit is enough for 100 analyzes.
SKU: 2553500
Mercury Reagent Set, 0.1-2.5µg/L Hg
Hach reagents for the determination of mercury. Range: 0.1 - 2.5 μg/L Hg. The test kit is enough for 25 tests.
SKU: 2658300
Chlorine dioxide reagent set 0.02 - 0.50 mg/L ClO2
Hach reagents for the determination of Chlorine Dioxide in the range 0.02 - 0.50 mg / l ClO2. The volume of reagents is enough for 100 tests.
SKU: HPT240
Reagent set for chlorine analyzer CL17sc, ultra low range
The reagent kit includes a total chlorine indicator solution, a total chlorine buffer solution, and a DPD compound.
SKU: 9791100
Recommended products
Volatile Acids Reagent Set, 27-2800mg/L HOAc
Hach reagent kit for the determination of volatile acids in the range of 27 - 2800 mg / l CH₃COOH (acetic acid). The kit is enough for 100 analyzes.
SKU: 2244700
Solution for determination of free ammonia
It is used to determine the concentration of free ammonia by the Indophenol method.
SKU: 2877436
SKU: 221120
Reagent for BioTector 1.8 N sulfuric acid, 80 mg/l MnSO4
Container with reagent for process TOC analyzer.
SKU: 25255061, 2563889
Cobalt / Nickel Reagent Set, PAN Method
For determination of Cobalt and Nickel by the PAN method. Hach Method 8078 (Co) and 8150 (Ni). Range: 0.01 - 2.00 mg/L Co, 0.006 - 1.000 mg/L Ni. Sample Size: 10 mL. Reagent set includes EDTA Reagent Powder Pillows, Phthalate-Phosphate Reagent Powder Pillows, and PAN Indicator Solution (0.3%) for approximately 100 tests.
SKU: 2651600
Molybdovanadate Reagent Solution (100 mL) 0.3 - 45.0 mg/L PO4
Hach reagents for the determination of phosphate (ortho). Range: 0.3 - 45.0 mg / l PO4. Volume 100 ml. Number of analyzes - 50.
SKU: 2076032
Sulfide Reagent Set, 5 - 800 µg/L S2-
Hach reagent kit for the determination of Sulfide 5 - 800 μg / l S2-. The kit is enough for 100 analyzes.
SKU: 2244500
Reagent set for the total hardness test kit HA-71A
Replacement reagent kit for determination of total hardness by drop count titration with EDTA using the HA-71A test kit.
SKU: 2437800
Manganese Reagent Set, PAN, 0.006-0.700mg/L Mn
Hach reagents for the determination of low manganese concentrations. Range: 0.006 - 0.700 mg / L Mn.
SKU: 2651700