Total Chlorine Reagent Set for chlorine analyser CL17/CL17sc

SKU: 2557000
Manufacturer: Hach
Availability: In stock
Total Chlorine Reagent Kit (includes DPD Indicator, Total Chlorine Indicator and Buffers).
Used with the CL17 / CL17sc analyzer and for serial analyzes.
Range 0.03 - 5.00 mg / L Cl2 for CL17 and 0.03 - 10.00 mg / L Cl2 for CL17sc.
Number of tests - 450.
Description Specifications Downloads Recommended products
Description
Description
Quality, Reliability
Hach Free Chlorine Reagent Set (DPD Indicator, Free Chlorine Indicator and Buffer Solutions) is specifically designed and produced to work with Hach CL17 Analyzers.
Simple, Predictable Maintenance
The CL17 is designed to require replacement of reagents on a predictable schedule under typical use. Maintenance can be performed in 15 minutes, and no special tools are required.
Parameter: Chlorine, total
Range: 0.03 - 5.00 mg / L Cl2 for CL17 and 0.03 - 10.00 mg / L Cl2 for CL17sc
Application: water analysis.
Method description: Chlorine can be in water as free available chlorine and as combined available chlorine. Both forms can be in the same water and can be determined together as the total available chlorine. Free chlorine is available as hypochlorous acid and/or hypochlorite ion. Combined chlorine exists as monochloramine, dichloramine, nitrogen trichloride and other chloro derivatives. The combined chlorine oxidizes iodide in the reagent to iodine. The iodine and free chlorine in the sample react with the DPD (N,N-diethyl- pphenylenediamine) indicator to form a pink color, which is proportional to the total chlorine concentration. To determine the concentration of combined chlorine, complete a free chlorine test and a total chlorine test. Subtract the free chlorine results from the results of the total chlorine test to obtain combined chlorine. The measurement wavelength is 530 nm.
Specifications
| Application area | Environmental monitoring, Wastewater, Reagents, Drinking water, Treatment facilities, Laboratory analysis, Process control |
| Type | Liquid reagents |
| Industry | Ecology, Pulp and paper, Power generation, Transport, Chemical, Food and Beverage, Municipal |
| Parameters | Chlorine total |
| Measurement Range | 0.03 - 5.00 mg/L Cl2 (CL17) |
| Compatibility | DR6000, DR3900 |
| Method | DPD |
| Number of tests | 450 |
| Measurement Range (2) | 0.03 - 10.00 mg/L Cl2 (CL17sc) |
| Quality control | 1426810, 2630020 |
Recommended products
2319800 Reagent kit for chloride determination, 0.1–25.0 mg/l Cl⁻
A set of reagents for the determination of chlorides by the mercury thiocyanate method.
SKU: 2319800
FerroZine Iron Reagent Solution, 0.009-1.400mg/L Fe
Hach reagents for the determination of Iron. Range: 0.009 - 1.400 mg / l Fe. Volume 500 ml.
SKU: 230149
SKU: 1.14767.0001
Volatile Acids Reagent Set, 27-2800mg/L HOAc
Hach reagent kit for the determination of volatile acids in the range of 27 - 2800 mg / l CH₃COOH (acetic acid). The kit is enough for 100 analyzes.
SKU: 2244700
Phosphax sc LR reagent kit
Reagent kit for industrial analyzer of orthophosphate concentration in wastewater (contains LCW956 + LCW957).
SKU: LCW955
181732 Sulfide 2 Reagent, 100 ml
For the determination of sulfide 5-800 µg/l S2-. Convenient dropper bottle.
SKU: 181732
Reagent kit Amtax sc with standard, for range 0.05-20.0 mg/L NH4-N
LCW865 Reagent Kit for Oline Ammonium Analyzer with Standard Calibration Solutions.
SKU: LCW865
SKU: 8035280100
SKU: 33156
Formaldehyde Reagent Set, 3-500 µg/L CH2O
Hach reagents for the determination of Formaldehyde in water. Range: 3-500 μg / L CH2O. Number of tests - 100.
SKU: 2257700
SKU: 245032
Mercury Reagent Set, 0.1-2.5µg/L Hg
Hach reagents for the determination of mercury. Range: 0.1 - 2.5 μg/L Hg. The test kit is enough for 25 tests.
SKU: 2658300
SKU: 1.04201.0100
Hardness Reagent Set, 8-1000 µg/L Ca & Mg as CaCO3
Hach reagents for hardness determination. Range: 8 - 1000 μg / L CaCO3. Number of tests - 100.
SKU: 2603100
SPADNS Fluoride Reagent Solution, 0.02 - 2.00 мг/л F 500 mL
Hach reagents for the determination of Fluoride. Range: 0.02 to 2.00 mg / L. Volume 500 ml.
SKU: 44449
SKU: 2257249
Silica Reagent Set, Bulk Solution, 3 - 1000 µg/L SiO2
Hach reagent kit for the determination of silicon dioxide in the ultra-low range 3 - 1000 μg / l SiO2. The kit is enough for 100 analyzes.
SKU: 2553500
Solution for the determination of molybdenum, 50 mL
Determination of molybdenum in the low range by Hach 8169 method.
SKU: 2352512
Lovibond DPD 1 Buffer Solution
Solution for the photometric determination of free/total chlorine in water samples.
SKU: 471010, 471016, 471011
Manganese Reagent Set, PAN, 0.006-0.700mg/L Mn
Hach reagents for the determination of low manganese concentrations. Range: 0.006 - 0.700 mg / L Mn.
SKU: 2651700
Reagent for BioTector 1.8 N sulfuric acid, 80 mg/l MnSO4
Container with reagent for process TOC analyzer.
SKU: 25255061, 2563889
Chlorine, liquid DPD reagent set, 0.02-2.00mg/L Cl2
Hach reagents for the determination of Chlorine in the analysis of drinking, waste and process water, as well as for control and monitoring of product quality. The reagent volume is sufficient for approximately 100 tests. Range 0.02 - 2.00 mg/L Cl2
SKU: HPT310
DPD 1 reagent solution (Lovibond), green bottle
Reagent for determining the concentration of total/free chlorine in water.
SKU: 471020, 471026, 471021
Recommended products
LeadTrak™ Reagent Set, Fast Column Extraction Method
Hach reagents for the determination of lead. Range: 5 - 150 μg/L Pb.
SKU: 2375000
Phosphate, ortho, Reagent Set 0.23 - 30.00 mg/L PO4
Hach reagents for the determination of phosphate (ortho). Range: 0.23 - 30.00 mg / l PO4. The reagent volume is sufficient for 100 analyzes.
SKU: 2244100
Mercury Reagent Set, 0.1-2.5µg/L Hg
Hach reagents for the determination of mercury. Range: 0.1 - 2.5 μg/L Hg. The test kit is enough for 25 tests.
SKU: 2658300
Reagent for PHOSPHAX sc 2 liters
Reagent for the industrial analyzer Hach Lange for the determination of orthophosphates in waste and drinking water.
SKU: LCW869
Hardness Reagent Set, Calmagite Colorimetric Method
Hach reagents for hardness determination. Range: 0.05 - 4.00 mg / L Ca as CaCO3 and 0.05 - 4.00 mg / L Mg as MgCO3.
SKU: 2319900
SKU: 2762133
SKU: 245032
Nitrification inhibitor for BOD, Trichloromethyl Pyridine (TCMP)
The BOD of carbonaceous compounds (CBOD) can be determined by adding a nitrification inhibitor. The CBOD test is recommended for biologically treated wastewater, biologically treated wastewater and river water samples.
SKU: 253335
SKU: 8035280100