Process COD analyzer EZ7000 - EZ7004 (dichromate method)
SKU: EZ7000.990A1C02
Manufacturer: Hach
Availability: Order only
The EZ700X Series COD Analyzers are single parameter titrators. The sampling line transfers the sample to the analyzer. The analyzer uses pumps, valves, and syringes to move the sample and reagents into a measuring cell on the analytical panel. When the measurement cycle is complete, the analyzer removes the sample through the drain line. The analysis results are displayed on the display of the data processing panel.
Includes mounting brackets, fittings, reagent containers, electrode, and user manual.
Description Specifications Recommended products
Description
Description
Ordering information
- EZ7000.990A1C02 - model EZ7000 measuring range 5 - 100 mg/l O2
- EZ7001.990A1C02 - model EZ7001 measuring range 40 - 500 mg/l O2
- EZ7002.990A1C02 - model EZ7002 measuring range 60 - 1000 mg/l O2
- EZ7003.990A1C02 - model EZ7003 measuring range 80 - 1500 mg/l O2
- EZ7004.990A1C02 - model EZ7004 measuring range 600 - 10,000 mg/l O2
EZ700X Online Analyzer Method for Determination of COD in Wastewater
Determination of COD concentration in a wastewater sample is based on titration with solution of ammonium-iron (II) sulfate (Mohr's salt). During the oxidation phase, organic compounds are oxidized and converted to carbon dioxide, nitrates and water, while potassium dichromate is converted to chromium (III). The amount of titration solution used is used to calculate the COD concentration in the sample.
Analysis steps
The sample is diluted and mixed with dichromate solution (K2Cr2O7) and sulfuric acid solution (H2SO4). The solution is heated to 135 °C for 15 minutes to oxidize the organic matter. After oxidation, titration is carried out with a solution of ammonium-iron (II) sulfate (Mohr's salt). The amount of titrant is used to calculate the COD concentration in the sample.
Chemical Oxygen Demand Analyzers Specifications
- Measurement method: Redox titration after oxidation with acidic potassium dichromate solution according to ISO 6060 method
- Detection limit: ≤ 5 mg/l
- Interference: chloride> 1 g/L, inorganic reducing agents such as nitrates, sulfides and iron (II) increase the result, aromatic hydrocarbons and pyridine are not oxidized to any appreciable degree. Some highly volatile organic compounds may not oxidize due to evaporation. Open chain aliphatic compounds are effectively oxidized with a silver sulfate / sulfuric acid solution. Fats, oils, proteins, surfactants and tar.
- Cycle time: 40 minutes including 30 minutes oxidation time
- Automatic cleaning: Yes
- Calibration: automatic, 2 points
- Ambient temperature: 10 - 30 °C ± 4 °C at 5 - 95% RH (no condensation)
- Reagent Requirements: Store 10 to 30 °C
- Flow rate: 100 - 300 ml/min
- Sample temperature: 10 - 30 °C
- Sample quality: maximum particle size 100 μm,
- Power supply: 230 V AC, 50/60 Hz; 120 VAC, 50/60 Hz; Max. power consumption: 440 VA
- Analog outputs: Active 4-20 mA max. Load 500 Ohm, standard 1, max. 8 (option)
- Digital outputs: optional: Modbus (TCP / IP, RS485)
- Material: folding part (hinges): Thermoform ABS; door: plexiglass; housing: galvanized steel, powder coated
- Dimensions (H x W x D) 690 mm x 465 mm x 330 mm
- Weight 25 kg
Specifications
Application area | Wastewater, Treatment facilities, Process control |
Type | Industrial |
Industry | Ecology, Municipal |
Parameters | COD |
Measurement Range | 5 - 10000 mg/L O2 |
Measurement method | Titrimetric |
Method | Dichromate |
Recommended products
EZ3000 / EZ3001 Ion Selective Ammonium Analyzers
Industrial analyzer for periodic (discontinuous) analysis of the concentration of ammonium NH4-N in water. Direct measurement with combined ion-selective electrode according to the APHA 4500-NH3 (D) standard method.
SKU: EZ3000.99001C02, EZ3001.99001C02
Titrimetric analyzer of total and calcium hardness EZ4043 / EZ4041 / EZ4044
The EZ4000 Series Hardness Analyzers are single parameter titrators: total hardness EZ4043 - Calmagit / EDTA method with a submersible LED probe, standard measurement range: 0.25 - 10 mg/L CaCO3; EZ4041 total hardness; calmagit / EDTA method, standard measurement range: 100 - 1000 mg/L CaCO3; EZ4044 Calcium hardness, standard measuring range: 10 - 1000 mg/L CaCO3.
SKU: EZ4041.99001C02, EZ4043.99001C02, EZ4044.99001C02
EZ1002 / EZ1003 Ammonium Colorimetric Analyzer
EZ1002 is a colorimetric measurement of ammonium concentration at 630 nm based on the APHA 3500-NH3 standard method (Berthelot). EZ1003 - colorimetric measurement at 450 nm in accordance with EPA Standard Method 350.1 (Nessler).
SKU: EZ1002.99001C02, EZ1003.99001C02
Process COD analyzer EZ7050 / EZ7051 (permanganate method)
The EZ7050 / EZ7051 Chemical Oxygen Demand Analyzers measure O2 concentrations in the range of 1 - 20 mg/L O2 and 20 - 200 mg/L O2, respectively. Titrimetric method.
SKU: EZ7050.990A1C02, EZ7051.990A1C02
Industrial titrator - Ammonium Analyzer EZ4005
The EZ4005 ammonium analyzer is a single parameter titrator with a wide measuring range: Standard measuring range: 100 - 5000 mg/L NH4-N.
SKU: EZ4005.99001C02
EZ1006 / EZ1007 Free and Total Chlorine Analyzers
The EZ Series online analyzers offer several options for monitoring chlorine in water. Typical applications are drinking water, surface water, process water. The EZ1000 Series analyzers use colorimetric method to measure chlorine. EZ1006 Chlorine free. EZ1007 Chlorine, total. Standard measuring range: 0.025 - 1.5 mg / l Cl2.
SKU: EZ1006.99001C02, EZ1007.99001C02
EZ4003 Free Alkalinity Analyzer
The EZ4003 Free Alkalinity Analyzers use an acid-base titration. Standard range 100 - 2500 mg/l CaCO3.
SKU: EZ4003.99001C02
EZ5000 Series Alkalinity and Hardness Analyzers
The instrument configuration "Total Hardness + Alkalinity" performs a sequence of two different titration methods: acid-base titration with a combination electrode for alkalinity determination and colorimetric titration for hardness determination in a single titration vessel. Combined measurement of two parameters in one analyzer is a convenient solution for operators and eliminates the need for additional space and the purchase of a second analyzer.
SKU: EZ5004.99001C02
Colorimetric Hardness Analyzer Envirolyzer EZ1000 Series
EZ1000 series analyzers use the colorimetric method of analysis: EZ1016 total hardness, EZ1017 calcium hardness, EZ1304 total hardness and calcium hardness, EZ1306 total hardness, calcium and magnesium hardness. Standard measuring range: 0.025 - 1 mg/L CaCO3.
SKU: EZ1016.99001C02
EZ4004 Process Total Alkalinity Analyzer
Online analyzer to determine the total alkalinity of water in real time.
SKU: EZ4004.99001C02
Recommended products
Process COD analyzer EZ7050 / EZ7051 (permanganate method)
The EZ7050 / EZ7051 Chemical Oxygen Demand Analyzers measure O2 concentrations in the range of 1 - 20 mg/L O2 and 20 - 200 mg/L O2, respectively. Titrimetric method.
SKU: EZ7050.990A1C02, EZ7051.990A1C02
Titrimetric analyzer of total and calcium hardness EZ4043 / EZ4041 / EZ4044
The EZ4000 Series Hardness Analyzers are single parameter titrators: total hardness EZ4043 - Calmagit / EDTA method with a submersible LED probe, standard measurement range: 0.25 - 10 mg/L CaCO3; EZ4041 total hardness; calmagit / EDTA method, standard measurement range: 100 - 1000 mg/L CaCO3; EZ4044 Calcium hardness, standard measuring range: 10 - 1000 mg/L CaCO3.
SKU: EZ4041.99001C02, EZ4043.99001C02, EZ4044.99001C02
Colorimetric Hardness Analyzer Envirolyzer EZ1000 Series
EZ1000 series analyzers use the colorimetric method of analysis: EZ1016 total hardness, EZ1017 calcium hardness, EZ1304 total hardness and calcium hardness, EZ1306 total hardness, calcium and magnesium hardness. Standard measuring range: 0.025 - 1 mg/L CaCO3.
SKU: EZ1016.99001C02
EZ1006 / EZ1007 Free and Total Chlorine Analyzers
The EZ Series online analyzers offer several options for monitoring chlorine in water. Typical applications are drinking water, surface water, process water. The EZ1000 Series analyzers use colorimetric method to measure chlorine. EZ1006 Chlorine free. EZ1007 Chlorine, total. Standard measuring range: 0.025 - 1.5 mg / l Cl2.
SKU: EZ1006.99001C02, EZ1007.99001C02
EZ3000 / EZ3001 Ion Selective Ammonium Analyzers
Industrial analyzer for periodic (discontinuous) analysis of the concentration of ammonium NH4-N in water. Direct measurement with combined ion-selective electrode according to the APHA 4500-NH3 (D) standard method.
SKU: EZ3000.99001C02, EZ3001.99001C02
EZ4003 Free Alkalinity Analyzer
The EZ4003 Free Alkalinity Analyzers use an acid-base titration. Standard range 100 - 2500 mg/l CaCO3.
SKU: EZ4003.99001C02
Industrial titrator - Ammonium Analyzer EZ4005
The EZ4005 ammonium analyzer is a single parameter titrator with a wide measuring range: Standard measuring range: 100 - 5000 mg/L NH4-N.
SKU: EZ4005.99001C02
EZ1002 / EZ1003 Ammonium Colorimetric Analyzer
EZ1002 is a colorimetric measurement of ammonium concentration at 630 nm based on the APHA 3500-NH3 standard method (Berthelot). EZ1003 - colorimetric measurement at 450 nm in accordance with EPA Standard Method 350.1 (Nessler).
SKU: EZ1002.99001C02, EZ1003.99001C02
EZ4004 Process Total Alkalinity Analyzer
Online analyzer to determine the total alkalinity of water in real time.
SKU: EZ4004.99001C02