Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Titration Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

SC4500 digital controller

hach-sc4500-tsifrovoy-kontroller.jpghach sc4500 insidesc4500 hach controller dimensions

SKU: LXV525.99C11551

Manufacturer: Hach

Availability: Order only

Order Add to comparison

SC4500 microprocessor-controlled and menu-driven controller that operates the sensors or analyzers.

Contents of delivery:

  • SC4500 controller
  • mounting hardware

Description

Description

The SC4500 is a 2-channel touchscreen controller for digital analytical devices (such as sensors and analyzers). The device can be mounted on a wall, panel, pole or pipe.

Installation and integration of the SC4500 controller is seamless thanks to the touch screen and Hach sensor support. This model has the same footprint as the SC200 controller.

The digital controller displays sensor measurements and other data on the display, can transmit analog and digital signals, and can also interact with and control other devices through outputs and relays. Outputs, relays, sensors and modules are configured and calibrated through the user interface on the front of the controller or remotely for controllers connected to the network.

SC4500 Benefits

  • Communication options: standard analog (4-20 mA) or digital protocols for Profinet, Ethernet IP and Modbus TCP. The controller has two Ethernet ports for optional LAN connection or for Modbus TCP / IP communication with PLC / SCADA. The controller is available with additional expansion modules that are installed at the factory depending on the selected configuration.
  • Wide range of compatible sensors: Dual sensor ports that are compatible with a line of 28 different sc series sensors.
  • Flexible installation and commissioning options: standard connection to your existing system. The controller also connects to Claros via cellular, Wi-Fi, or LAN connection. The Claros system allows you to easily connect and manage instruments, data and processes - anywhere, anytime. The Prognosys diagnostic system displays the status of the maintenance tasks and the status of the instrument status.

SC4500 Compatibility with Hach Probes and Analyzers

  • Amtax sc / V2.30 (2018) or higher
  • A-ISE sc / V1.02 or higher
  • AN-ISE sc / V1.08 (2013) or higher
  • N-ISE sc / V1.02 or higher
  • Nitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higher
  • Phosphax sc / V2.30 (2018) or higher
  • Phosphax sc LR / MR / HR / V1.01 (2018) or higher
  • TSS sc / V41.73 (2013) or higher
  • Solitax sc / V2.20 (2013) or higher
  • TU5300sc, TU5400sc / V1.34 (2017) or higher
  • Ultraturb sc / V3.06 (2017) or higher
  • 1720E / V2.10 (2006) or higher
  • Sonatax sc / V1.15 (2016) or higher
  • CL17sc / V2.7 (2019) or higher
  • CL10sc / V1.14 (2013) or higher
  • 9184sc, 9185sc, 9187sc * / V2.03 (2013) or higher
  • Uvas plus sc / V3.01 (2017) or higher
  • LDO 2 sc * / V1.22 (2013) or higher
  • 3798sc * / V2.03 (2013) or higher
  • 3700sc + Gateway for inductive conductivity sensors 6120800 / V3.00 (2017) or higher
  • 3422sc, Analog 3400 + Conductive Conductivity Gateway 6120700 / V3.00 or higher
  • pHD sc *, pHD-S sc / V3.10 (2016) or higher
  • 1200-S sc * / V2.04 (2013) or higher
  • pHD analog + Gateway 6120500 / V3.00 (2017) or higher
  • Analogue RC and PC + sensors Gateway for analogue pH and ORP sensors 6120600 / V3.00 (2017) or higher
  • 8362sc * / V3.00 (2017) or higher

Technical specifications

  • Dimensions ½ - DIN144 x 144 x 192 mm
  • Weight 1.7 kg (controller only, no modules)
  • Display 3.5 '' TFT color display with touch panel
  • Enclosure protection class UL50E type 4X, IEC / EN 60529 – IP 66, NEMA 250 type 4X. Corrosion-resistant metal housing
  • Operating temperature range
    -20 to 60 °C (8 W (AC) / 9 W (DC) sensor load)
    -20 to 45 °C (28 W (AC) / 20 W (DC) sensor load)
    Linear derating between 45 and 60 °C (-1.33 W/°C)
  • Storage conditions -20 to 70 °C, 0 to 95% RH, non-condensing
  • Power Requirements
    AC controller: 100-240 VAC ± 10%, 50/60 Hz; 1 A (28 W sensor load)
    DC controller: 18–28 VDC; 2.5 A (12W with 9W sensor load, 36W with 20 W sensor load)
  • Measurements Two device digital SC connectors
  • Communication (optional)
    Analog: Five 0-20 mA or 4-20 mA analog outputs on each analog output module. Up to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.
    Digital: Profibus DPV1 Modbus TCP Module Profinet IO Module Ethernet IP Module
  • Network connectivity LAN: Two Ethernet connectors (10/100 Mbps); Cellular: External 4G; Wi-Fi
  • USB port is used for uploading data and downloading software. The controller records approximately 20,000 data points for each connected sensor.

Order Information

LXV525.99A11551 SC4500 Controller, Prognosys, 5x mA Output, 2 digital Sensors, without plug
LXV525.99C11551 SC4500 Controller, Prognosys, 5x mA Output, 2 digital Sensors, EU plug
LXV525.99A11541 SC4500 Controller, Prognosys, 5x mA Output, 1 digital Sensor, 1 mA Input, without plug
LXV525.99C11541 SC4500 Controller, Prognosys, 5x mA Output, 1 digital Sensor, 1 mA Input, EU plug
LXV525.99AA1551 SC4500 Controller, Claros-enabled, 5x mA Output, 2 digital Sensors, without plug
LXV525.99CA1551 SC4500 Controller, Claros-enabled, 5x mA Output, 2 digital Sensors, EU plug
LXV525.99AA1541 SC4500 Controller, Claros-enabled, 5x mA Output, 1 digital Sensor, 1 mA Input, without plug
LXV525.99C11541 SC4500 Controller, Prognosys, 5x mA Output, 1 digital Sensor, 1 mA Input, EU plug

Specifications

Specifications

Application areaEnvironmental monitoring, Wastewater, Food production, Treatment facilities, Beverages, Process control, Water supply
TypeIndustrial
IndustryPulp and paper, Power generation, Chemical, Food and Beverage, Municipal
ParametersAmmonium, Phosphate, Dissolved oxygen, Conductivity, Orthophosphates, Ozone, ORP (redox potential), Nitrate, Turbidity, Chlorine dioxide, pH, Chlorine free, Chlorine total, Hypochlorite, Sediment, Suspended solids, Organic load , Active chlorine
Power supply50/60 Hz / 100 - 240 V AC
Number of inputstwo-channel
Operating temperature range-20 - 60 °C
Video
Recommended products

Recommended products

SC1000 Probe module for 4 sensors, Prognosys

SC1000 Probe module for 4 sensors, Prognosys

SC1000 Probe module for 4 sensors.

SKU: LXV400.99.0G021

View product Compare

SC200 Digital 2-channel controller

SC200 Digital 2-channel controller

HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.

SKU: LXV404.99.00551

View product Compare

SC1000 Probe module for 8 sensors

SC1000 Probe module for 8 sensors

SC1000 Probe module for 8 sensors.

SKU: LXV400.99.20041

View product Compare

SC1000 Probe module for 4 sensors

SC1000 Probe module for 4 sensors

Universal digital controller SC1000, for connecting up to 4 SC sensors with 1 analogue output card with 4 x 0 / 4-20 mA output.

SKU: LXV400.99.00121

View product Compare

SC1000 Probe module for 6 sensors, Prognosys

SC1000 Probe module for 6 sensors, Prognosys

SC1000 Probe module for 6 sensors.

SKU: LXV400.99.0G031

View product Compare

Display module for multi-parameter controller SC1000

Display module for multi-parameter controller SC1000

Touch display for SC1000 universal digital controller.

SKU: LXV402.99.00001

View product Compare

Accessories

Accessories

UV protection shield for SC4200c and SC4500 controllers

UV protection shield for SC4200c and SC4500 controllers

Sun protection panel for SC controllers.

SKU: LXZ524.99.00004

View product Compare

UV protection housing for SC4200c and SC4500 controllers

UV protection housing for SC4200c and SC4500 controllers

Sun protection housing for SC controllers.

SKU: LXZ524.99.00005

View product Compare

Sunroof visor for SC4200c and SC4500 controllers

Sunroof visor for SC4200c and SC4500 controllers

Visor for controllers protection from changes in weather conditions.

SKU: LXZ524.99.00033

View product Compare

Related products

1200-S sc Digital pH sensor for SC controller

1200-S sc Digital pH sensor for SC controller

Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.

SKU: LXV426.99.10001

View product Compare

Solitax inline sc process turbidity and suspended solids sensor

Solitax inline sc process turbidity and suspended solids sensor

Solitax inline sc tube-mounted sensor for turbidity (0.001 - 4000 NTU) and suspended solids (0.001 - 50 g/l) in stainless steel with 10 meter cable.

SKU: LXV424.99.00100, LXV424.99.02100

View product Compare

CL17 sc Photometric Chlorine Analyzer

CL17 sc Photometric Chlorine Analyzer

The Hach CL17 sc analyzer is used for continuous monitoring and determination of the concentration of free or total residual chlorine in water. Readings are not affected by changes in chlorine concentration, sample pH, temperature, flow rate, or pressure. The CL17 sc is also suitable for measuring residual permanganate content. Research demonstrates the analyzer's analytical capabilities and confirms that it is a reliable solution and a good tool for managing complex water purification and disinfection processes.

SKU: 8574500, 8574400

View product Compare

9184 sc Amperometric analyzer for active chlorine

9184 sc Amperometric analyzer for active chlorine

The Chlorine Analyzer 9184sc is a single-channel industrial sensor that measures chlorine concentrations in wastewater treatment plants, potable water production, distribution networks and other applications where monitoring of active chlorine from 0 to 20 mg/L HOCl is required.

SKU: LXV432.99.00001, LXV430.99.00001

View product Compare

Phosphax sc LR low range orthophosphate analyzer

Phosphax sc LR low range orthophosphate analyzer

Accurate analyzer for measuring the concentration of orthophosphates in the low range of 0.015 - 2 mg/l PO4-P in waste water.

SKU: LXV422.99.33001, LXV422.99.33011

View product Compare

AN-ISE sc immersion ammonium and nitrate ion-selective probe

AN-ISE sc immersion ammonium and nitrate ion-selective probe

The Hach AN-ISE sc digital combination ammonium and nitrate sensor performs continuous direct measurements using an ion selective electrode. No reagents or sample preparation required. Automatic and simultaneous potassium and chloride compensation. Easy handling and low maintenance thanks to the Cartrical plus sensor cartridge with five electrodes.

SKU: LXV440.99.00001

View product Compare

A-ISE sc NH4-N Immersion Ion Selective Probe

A-ISE sc NH4-N Immersion Ion Selective Probe

The digital ion selective probe A-ISE sc Hach is designed to determine the concentration of ammonium directly in the medium. No calibration required. Automatic potassium compensation. The sensor is easy to handle. Low maintenance thanks to the cartridge system. The A-ISE sc is particularly economical in terms of installation and operation, even in small wastewater treatment plants.

SKU: LXV440.99.10001, LXV440.99.10011

View product Compare

TU5300sc and TU5400sc online turbidity analyzers

TU5300sc and TU5400sc online turbidity analyzers

The TU5300 sc and TU5400 sc turbidity meters are used with the sc controller to measure low turbidity, mainly in drinking water systems. The TU5300 sc and TU5400 sc turbidity meters measure the scattered light at a 90° angle in a 360° radius around the axis of the incident light beam.

SKU: LXV445.99.10112, LXV445.99.10212

View product Compare


Show more