Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Titration Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

A-ISE sc NH4-N Immersion Ion Selective Probe

hach-a-ise-sc-datchik-ammoniya-s-rfid.jpgLXV440.99.10001 ammonium sensor A-ISEreplaceable cartridge for sensor

SKU: LXV440.99.10001, LXV440.99.10011

Manufacturer: Hach

Availability: Order only

Order Add to comparison

The A-ISE sc probe uses ion selective electrode technology to detect ammonium ions NH4 + in a wastewater sample. Potassium and temperature interferences are compensated by the built-in electrodes.

Scope of delivery: ammonium sensor (0 - 1000 mg/L NH4-N), cartridge, user manual.

An SC series digital controller is required for power supply and data transmission (not included).


Description

Description

Ammonium is one of the key parameters in wastewater treatment plants. The ability to reliably record and manage this parameter plays an important role in the efficient management of the wastewater treatment process.

The A-ISE industrial ammonium sensor performs continuous measurements directly in the medium. Thanks to the ion selective electrode technology, there is no need for reagents or sample preparation. As the concentration of ammonium NH4-N in wastewater can be measured during the actual process it reduces downtime, costs and maintenance time.

The only serviceable part of the sensor is a cartridge (LZY694) containing an ammonium, potassium electrode (compensation) and a temperature sensor. Cartrical plus technology simplifies cartridge installation and replacement. The compact cartridges are calibrated at the factory using special standard solutions, so no maintenance is required on the cartridge itself. The factory-calibrated sensor code is automatically transferred to the system. This provides reliable measured values and significantly reduces maintenance time and costs compared to conventional ion selective sensors. Replacing the cartridge is simple: unscrew the old cartridge, insert the new one, and the sensor is ready for use again. The membranes of the electrodes sensitive to ammonium ions are reliably protected; therefore, the cartridge needs to be replaced only once a year.

  • LXV440.99.10001 - ammonium ISE probe, range 0 - 1000 mg/L NH4-N with RFID technology; With RFID technology, factory calibration is automatically detected after a cartridge is replaced.
  • LXV440.99.10011 - ammonium ISE probe, range 0 - 1000 mg/L NH4-N without RFID technology.

Specifications: ammonium sensor A-ISE Hach Lange

  • Measurement method Potentiometric ion-selective measurement
  • Measuring range 0 - 1000 mg/l NH4-N
  • pH range 5 - 9 pH
  • Accuracy 5% of mv + 0.2 mg / l (with standard solutions) NH4-N
  • Response time < 3 min
  • Measurement interval continuous
  • Detection limit 0.2 mg/l NH4-N
  • Dimensions (Ø x L) 84.5 mm x 320 mm
  • Installation angle 45° ± 15° (vertical to flow direction)
  • Cable length 10 m Fixed cable on the sensor, expandable up to 100 m
  • Sample pressure 0.3 bar max.
  • Storage conditions sensor cartridge 5 - 40 °C
  • Weight 2.4 kg
  • Sample temperature 2 - 40 °C
  • Operating temperature range - 20 - 45 °C
  • Calibration method with Cartrical plus technology: automatic import of factory calibration data from the cartridge to the sensor using RFID *; 1- and 2-point matrix correction
  • Materials in contact with water: probe: stainless steel 1.4571; ASA + PC, silicon; PVC and PU; sensor cartridge: PVC; POM; ABS; Stainless steel 1.4571; NBR

 

Specifications

Specifications

Application areaWastewater, Process control
TypeIndustrial
IndustryMunicipal
ParametersAmmonium
Measurement Range0 - 1000 mg/L NH4-N
Measurement methodISE
Recommended products

Recommended products

Solitax ts-line sc submersible turbidity and suspended solids sensor, PVC

Solitax ts-line sc submersible turbidity and suspended solids sensor, PVC

Solitax ts-line sc probe for measuring turbidity (0.001 - 4000 NTU) and suspended solids (0.001-50 g / l). Optics holder and cover made of black PVC. Cable 10 meters.

SKU: LXV423.99.10100, LXV423.99.12100

View product Compare

Ammonium analyzers Hach Amtax sc

Ammonium analyzers Hach Amtax sc

High-precision industrial device for the determination of ammonium in water, waste water and activated sludge. Amtax sc measures ammonium concentration using a gas selective electrode (GSE). Designed for outdoor or indoor installation.

SKU: LXV421.99.???1

View product Compare

NITRATAX sc series immersion nitrate sensors

NITRATAX sc series immersion nitrate sensors

The Hach Nitratax sc family includes digital optical sensors for highly accurate determination of nitrate concentration directly in the medium. Nitratax sc nitrate sensors with a high degree of accuracy through direct measurement of UV light, without cross-sensitivity, are ideal for monitoring Maximum Allowable Concentrations.

SKU: LXV415.99.10001

View product Compare

AN-ISE sc immersion ammonium and nitrate ion-selective probe

AN-ISE sc immersion ammonium and nitrate ion-selective probe

The Hach AN-ISE sc digital combination ammonium and nitrate sensor performs continuous direct measurements using an ion selective electrode. No reagents or sample preparation required. Automatic and simultaneous potassium and chloride compensation. Easy handling and low maintenance thanks to the Cartrical plus sensor cartridge with five electrodes.

SKU: LXV440.99.00001

View product Compare

Accessories

Accessories

SC200 Digital 2-channel controller

SC200 Digital 2-channel controller

HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.

SKU: LXV404.99.00551

View product Compare

SC1000 Probe module for 4 sensors

SC1000 Probe module for 4 sensors

Universal digital controller SC1000, for connecting up to 4 SC sensors with 1 analogue output card with 4 x 0 / 4-20 mA output.

SKU: LXV400.99.00121

View product Compare

Replacement cartridge for AN-ISE sc, A-ISE sc and N-ISE sc probes

Replacement cartridge for AN-ISE sc, A-ISE sc and N-ISE sc probes

Cartridge for process Hach Lange ion-selective sensors for the determination of ammonium and nitrates.

SKU: LZY694

View product Compare

SC4500 digital controller

SC4500 digital controller

The SC4500 is a dual channel controller for digital analytical devices (such as sensors and analyzers). The controller shows sensor measurements and other data on the display, can transmit analog and digital signals, and can also interact with other devices and control them through outputs and relays.

SKU: LXV525.99C11551

View product Compare

Recommended products