Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

LCK318 Sludge activity (TTC) cuvette test

hach-lck318-kyuvetnyj-test-na-aktivnost-ila-ttc.jpegLCK318 Hach sludge activity reagent

SKU: LCK318

Manufacturer: Hach

Availability: Order only

Order Add to comparison

A set of reagents for determining the activity of sludge in wastewater.
Measuring range 5-200 µg Formazan (SA); 0 - 500% Residual Activity (RA).
According to standard: DIN 38412-3
Storage temperature: 2 - 8 ° C


Description

Description

Cuvette test LCK318 for determining the activity of sludge in wastewater from the manufacturer Hach. The reagent kit is suitable for use with the DR series spectrophotometer. The method complies with DIN 38412-3.

Application: For activated sludge, digested sludge, municipal and industrial waste water.

Parameter: Sludge activity.

Description: Screening test for sludge activity (TTC-SA) or residual sludge activity (TTC-RA)

Method description: Determination of sludge activity or residual activity (activated sludge, fermented sludge, etc.) with 2,3,5-triphenyltetrazolium chloride (TTC) based on dehydrogenase activity. TTS is converted to red formazan by dehydrogenases. Formazan, insoluble in water, is extracted with ethanol and determined photometrically.

Specifications

Specifications

Application areaEnvironmental monitoring, Test kits, Wastewater, Reagents, Treatment facilities
TypeCuvette tests 13 mm
IndustryEcology, Pulp and paper, Power generation, Transport, Chemical, Food and Beverage, Municipal
ParametersSludge activity
Measurement Range5 - 200 µg Formazan (SA)
CompatibilityDR6000, DR1900, DR3900, DR5000, DR2800, DR3800
MethodColorimetric
Compliance with the standardDIN 38409-H7
Measurement Range (2)0 - 500 % Residual activity (RA)
Video
Downloads

Downloads

Working procedure: LCK318 Sludge activity (TTC) Screening
Recommended products

Recommended products

LCW058 hydrogen peroxide pipette test, 1 - 10 g/L H2O2

LCW058 hydrogen peroxide pipette test, 1 - 10 g/L H2O2

LCW058 hydrogen peroxide test. Measurement range 1 - 10 g/L H2O2

SKU: LCW058

View product Compare

LCW025 Hydrazine reagent kit, 0,01 - 2,0 mg/L N2H4

LCW025 Hydrazine reagent kit, 0,01 - 2,0 mg/L N2H4

LCW025 reagent kit for the determination of hydrazine, measuring range 0,01 - 2,0 mg/L N2H4.

SKU: LCW025

View product Compare

LCK049 Orthophosphate cuvette test 1,6 - 30 mg/L PO4-P

LCK049 Orthophosphate cuvette test 1,6 - 30 mg/L PO4-P

A set of reagents for the determination of orthophosphate, measuring range: 1,6 - 30 mg /L PO4-P / 5 - 90 mg/L PO4.

SKU: LCK049

View product Compare

LCK411.00 Anammox Activity cuvette test, 0 - 1000 mAbs

LCK411.00 Anammox Activity cuvette test, 0 - 1000 mAbs

Reagent kit for the determination of Anammox Activity, measuring range 0 - 1000 mAbs. Kit includes: reagents for 25 tests (LCK411), 25 cuvettes (LCW906).

SKU: LCK411.00

View product Compare

LCK362 Acid capacity KS4.3 cuvette test, 0,5 - 8,0 mmol/L

LCK362 Acid capacity KS4.3 cuvette test, 0,5 - 8,0 mmol/L

LCK362 cuvette test for determination of Acid capacity KS4.3, measurement range 0,5 - 8,0 mmol/L

SKU: LCK362

View product Compare

LCK364 Zirconium cuvette test, 6 - 60 mg/L Zr

LCK364 Zirconium cuvette test, 6 - 60 mg/L Zr

LCK364 cuvette test for the determination of Zirconium, measuring range 6 - 60 mg/L Zr.

SKU: LCK364

View product Compare

LCK348 Phosphate Ortho/Total cuvette test 0,5 - 5,0 mg/L PO4-P

LCK348 Phosphate Ortho/Total cuvette test 0,5 - 5,0 mg/L PO4-P

Phosphate reagent kit (Ortho/Total), measuring range 0,5 - 5,0 mg/L PO4-P.

SKU: LCK348

View product Compare

LCK228 Potassium cuvette test, 5 - 50 mg/L K

LCK228 Potassium cuvette test, 5 - 50 mg/L K

Potassium reagent kit, measuring range 5 - 50 mg / L K.

SKU: LCK228

View product Compare

LCK242 Vicinal diketones cuvette test, 0,015 - 0,5 mg/kg Diacetyl

LCK242 Vicinal diketones cuvette test, 0,015 - 0,5 mg/kg Diacetyl

LCK242 cuvette test for determination of vicinal diketones, measuring range 0,015 - 0,5 mg/kg Diacetyl.

SKU: LCK242

View product Compare

LCK327 Water Hardness cuvette test 1-20° dH

LCK327 Water Hardness cuvette test 1-20° dH

Test kit for determining water hardness, measuring range 1-20 ° dH; 5 - 100 mg / l Ca; 3 - 50 mg / l Mg.

SKU: LCK327

View product Compare

LCI500 COD cuvette test, 0 - 150 mg/L O2

LCI500 COD cuvette test, 0 - 150 mg/L O2

A set of reagents for the determination of COD; measuring range 0 - 150 mg/L O2.

SKU: LCI500

View product Compare

LCK350 Phosphate Ortho/Total cuvette test 2,0 - 20,0 mg/L PO4-P

LCK350 Phosphate Ortho/Total cuvette test 2,0 - 20,0 mg/L PO4-P

Phosphate reagent kit (Ortho/Total), measuring range 2,0 - 20,0 mg/L PO4-P.

SKU: LCK350

View product Compare

LCW028 Silica Reagent Set, 0,01 - 0,8 mg/L SiO2

LCW028 Silica Reagent Set, 0,01 - 0,8 mg/L SiO2

LCW028 reagent kit for determination of Silicа, measuring range 0,01 - 0,8 mg/L SiO2.

SKU: LCW028

View product Compare

LCK386 TOC cuvette test (purging method) 30 - 300 mg/L C

LCK386 TOC cuvette test (purging method) 30 - 300 mg/L C

Reagent kit for determination of total organic carbon (TOC); measuring range 30 - 300 mg/l C.

SKU: LCK386

View product Compare

LCK355 Silver cuvette test, 5 - 2500 mg/L Ag

LCK355 Silver cuvette test, 5 - 2500 mg/L Ag

Test kit for the determination of Silver, two measuring ranges 5 - 400 mg/L Ag / 400 - 2500 mg/L Ag.

SKU: LCK355

View product Compare

LCK319 Cyanide (easily liberatable) cuvette test 0,03 - 0,35 mg/L CN

LCK319 Cyanide (easily liberatable) cuvette test 0,03 - 0,35 mg/L CN

Cyanide test kit, measuring range 0.03 - 0.35 mg / l CN.

SKU: LCK319

View product Compare

LCK310 Chlorine (Cl2)/ Ozone (O3)/ Chlorine Dioxide (ClO2) cuvette test

LCK310 Chlorine (Cl2)/ Ozone (O3)/ Chlorine Dioxide (ClO2) cuvette test

Test kit for the determination of Chlorine (Cl2), Ozone (O3), Chlorine Dioxide (ClO2).

SKU: LCK310

View product Compare

LCK385 TOC cuvette test, 3 - 30 mg/L O2

LCK385 TOC cuvette test, 3 - 30 mg/L O2

Reagent kit for the determination of TOC. Measurement range 3 - 30 mg / L O2.

SKU: LCK385

View product Compare

LCK342 Nitrite cuvette test, 0,6 - 6,0 mg/L NO2-N

LCK342 Nitrite cuvette test, 0,6 - 6,0 mg/L NO2-N

A set of reagents for the determination of nitrites, measuring range 0,6 - 6,0 mg/L NO2-N / 2 - 20 mg/L NО2.

SKU: LCK342

View product Compare

LCK313 Chromium (III and VI) cuvette test 0,03 - 1,0 mg/L Cr

LCK313 Chromium (III and VI) cuvette test 0,03 - 1,0 mg/L Cr

A set of reagents for the determination of Chromium (III and VI), measuring range 0,03 - 1,0 mg / L Cr.

SKU: LCK313

View product Compare

LCW054 Sulphite test kit, 0,1 - 5,0 mg/L SO3

LCW054 Sulphite test kit, 0,1 - 5,0 mg/L SO3

LCW054 test kit for the determination of Sulphites, measuring range 0,1 - 5,0 mg/L SO3.

SKU: LCW054

View product Compare

LCK1414, COD cuvette test for samples with high Chloride loads 100 - 2000 mg/L O2

LCK1414, COD cuvette test for samples with high Chloride loads 100 - 2000 mg/L O2

COD reagent kit for samples with high chloride content, measuring range 100 - 2000 mg / l O2.

SKU: LCK1014

View product Compare

LCI400 COD cuvette test, 0 - 1000 мг/л O2

LCI400 COD cuvette test, 0 - 1000 мг/л O2

A set of reagents for the determination of COD; measuring range 0 - 1000 mg/L O2

SKU: LCI400

View product Compare

LCK328 Potassium cuvette test, 8 - 50 mg/L K

LCK328 Potassium cuvette test, 8 - 50 mg/L K

Potassium reagent kit, measuring range 8 - 50 mg / L K.

SKU: LCK328

View product Compare