LCK213 Chromic acid baths cuvette test 0,5 - 450 g/L CrO3

SKU: LCK213
Manufacturer: Hach
Availability: Order only
A set of reagents for chromium for acidic galvanic baths.
Measurement range 0.5 - 5.0 g / l CrO3.
Measuring range (2) 50 - 450 g / l CrO3.
The number of tests in a package is 25 pieces.
Description Specifications Video Downloads Recommended products
Description
Description
LCK213 Chromium Cuvette Test for Electroplating Baths from Hach.
Applications: for chrome plating baths.
Description of the method: Chromic acid (chromium trioxide - CrO3) dissolves in dilute acids, forming chromates with an intense yellow color. Yellow is assessed photometrically. The temperature of the water sample and reagents should be between 15-25 ° C.
Specifications
| Application area | Test kits, Reagents |
| Type | Cuvette tests 13 mm |
| Industry | Ecology, Pulp and paper, Pharmaceutical, Glass, Power generation, Transport, Chemical, Food and Beverage, Municipal |
| Measurement Range | 0,5 - 5,0 g/l CrO3 |
| Compatibility | DR6000, DR1900, DR3900, DR5000, DR2800, DR3800 |
| Method | Colorimetric |
| Number of tests | 25 |
| Measurement Range (2) | 50 - 450 g/L CrO3 |
Recommended products
LCK554 BOD5 cuvette test, 0,5 - 12,0 mg/L O2
A set of reagents for the determination of BOD5, measuring range 0,5 - 12,0 mg / L О2.
SKU: LCK554
LCK342 Nitrite cuvette test, 0,6 - 6,0 mg/L NO2-N
A set of reagents for the determination of nitrites, measuring range 0,6 - 6,0 mg/L NO2-N / 2 - 20 mg/L NО2.
SKU: LCK342
LCK360 Zinc cuvette test, 0,2 - 6,0 mg/L Zn
A set of reagents for the determination of Zinc, measuring range 0,2 - 6,0 mg/L Zn.
SKU: LCK360
LCK315 Cyanide cuvette test, 0,01 - 0,6 mg/L CN
LCK315 Cyanide cuvette test, measuring range 0,01 - 0,6 mg/L CN.
SKU: LCK315
LCW903 Calcium separation kit
The kit is designed for high calcium/magnesium water samples prepared for cadmium determination.
SKU: LCW903
LCW532 Manganese reagent set, 0,005 - 0,5 mg/L Mn
A set of reagents for the determination of manganese, measuring range 0,005 - 0,5 mg/L Mn.
SKU: LCW532
LCS028 Silica acid (high range) reagent set 0,8 - 100 mg/L SiO2
LCS028 reagent kit for silicic acid and silicon, measuring range 0.8 - 100 mg / l SiO2 or 0.4 - 50 mg / l Si
SKU: LCS028
LCS313 Chromium (III and VI) trace cuvette test, 0,005 - 0,25 mg/L Cr
A set of reagents for the determination of chromium traces (III and VI), measuring range 0,005 - 0,25 mg/L Cr.
SKU: LCS313
LCK1414, COD cuvette test 5 - 60 mg/L O2
COD reagent kit, measuring range 5 - 60 mg/L O2.
SKU: LCK1414
LCS360 Zinc trace cuvette test, 0,02 - 0,8 mg/L Zn
Reagent kit for determination of zinc traces, measuring range 0,02 - 0,8 mg / l Zn.
SKU: LCS360
LCK391 AOX cuvette test 0.005 - 0.5 mg/L
LCK391 cuvette test for the determination of AOX (Adsorbable organic halogen compounds), measuring range 0.005 - 0.5 mg / l
SKU: LCK391
LCK138 Laton Total Nitrogen bonded cuvette test 1 - 16 mg/L TNb
Test kit for determination of total Nitrogen bonded, measuring range 1 - 16 mg/L TNb.
SKU: LCK138
LCK311 Chloride cuvette test 1-70 mg/L / 70-1000 mg/L Cl
LCK311 Chloride cuvette test, measuring range 1 - 70 mg/L / 70 - 1000 mg/L Cl.
SKU: LCK311
LCK343 Nitrite cuvette test, 2–90 mg/L NO2-N
A set of reagents for the determination of nitrites, measuring range 2–90 mg/L NO2-N.
SKU: LCK343
LCK049 Orthophosphate cuvette test 1,6 - 30 mg/L PO4-P
A set of reagents for the determination of orthophosphate, measuring range: 1,6 - 30 mg /L PO4-P / 5 - 90 mg/L PO4.
SKU: LCK049
LCK514 COD cuvette test, 100 - 2000 mg/L O2
COD test kit, measuring range 100 - 2000 mg/L O2.
SKU: LCK514
LCK549 Orthophosphate cuvette test, 0,01 - 0,5 mg/L PO4-P
Cuvette test for the determination of Orthophosphate, measuring range 0,01 - 0,5 mg/L PO4-P.
SKU: LCK549
LCK242 Vicinal diketones cuvette test, 0,015 - 0,5 mg/kg Diacetyl
LCK242 cuvette test for determination of vicinal diketones, measuring range 0,015 - 0,5 mg/kg Diacetyl.
SKU: LCK242
LCW250 Reducing agent for boiler water reagent set, 0,05 - 1,0 mg/L (DEHA)
LCW250 reagent set for the determination of reducing agents for boiler water. Measuring range 0,05 - 1,0 mg/L (DEHA)
SKU: LCW250
LCK229 Acidic copper plating baths cuvette test 2-100 g/L Cu
Reagent kit LCK229 for the determination of copper for acidic galvanic baths, measuring range 2 - 100 g / l Cu.
SKU: LCK229
LCK386 TOC cuvette test (purging method) 30 - 300 mg/L C
Reagent kit for determination of total organic carbon (TOC); measuring range 30 - 300 mg/l C.
SKU: LCK386
LCK328 Potassium cuvette test, 8 - 50 mg/L K
Potassium reagent kit, measuring range 8 - 50 mg / L K.
SKU: LCK328
LCK300 Alcohol cuvette test, 0,01 - 0,12 g/L C2H5OH
LCK300 cuvette test for the determination of Alcohol, measuring range 0,01 - 0,12 g/L C2H5OH
SKU: LCK300
LCK359 Tin cuvette test 0,1 - 2 mg/L Sn
A set of reagents for the determination of tin, measuring range 0,1 - 2 mg / L Sn.
SKU: LCK359
Recommended products
LCK306 lead cuvette test 0,1 - 2,0 mg/L Pb
Test kit for determination of lead, measuring range 0.1 - 2.0 mg / l Pb.
SKU: LCK306
LCK360 Zinc cuvette test, 0,2 - 6,0 mg/L Zn
A set of reagents for the determination of Zinc, measuring range 0,2 - 6,0 mg/L Zn.
SKU: LCK360
LCW028 Silica Reagent Set, 0,01 - 0,8 mg/L SiO2
LCW028 reagent kit for determination of Silicа, measuring range 0,01 - 0,8 mg/L SiO2.
SKU: LCW028
LCK537 Nickel trace cuvette test, 0,05 - 1,0 mg/L Ni
Reagent kit for Nickel trace, measurement range 0,05 - 1,0 mg/L Ni.
SKU: LCK537
LCK238 Laton Total Nitrogen cuvette test 5-40 mg/L TN
Test kit for determination of total Nitrogen, measuring range 5-40 mg/L TN.
SKU: LCK238
LCK338 Laton Total Nitrogen cuvette test, 20 - 100 mg/L TN
Test kit for determination of total Nitrogen, measuring range 20 - 100 mg/L TN.
SKU: LCK338
LCK390 cuvette test AOX, 0,05 - 3,0 mg/L
LCK390 cuvette test for determination of AOX, measurement range 0,05 - 3,0 mg/L
SKU: LCK390
LCK339 Nitrate cuvette test, 0,23 - 13,5 mg/L NO3-N
Reagent kit for the determination of Nitrate, measuring range 0,23 - 13,5 mg/L NO3-N.
SKU: LCK339
LCK349 Phosphate (Ortho/Total) cuvette test 0,05 - 1,5 mg/L PO4-P
Phosphate reagent kit (Ortho/Total), measuring range 0,05 - 1,5 mg/L PO4-P / 0,15 - 4,5 mg/L PO4.
SKU: LCK349