In non-apoptotic cells, the JC-1 dye enters the mitochondria, which causes a fluorescence redshift from green (~ 529 nm) to red (~ 590 nm). Depolarization of mitochondria will cause a green shift in cells, indicating that they are apoptotic.
Used for measurements using the NC-3000 for Mitochondrial Potential Analysis in combination with Solution 8.
Description Recommended products
Description
Description
The programmed method in the NucleoCounter® NC-3000 automatic analyzer allows the user to measure mitochondrial transmembrane potential using the cationic dye JC1 (5, 5, 6, 6-tetrachloro-1, 1, 3, 3 tetraethylbenzimidazole carbocyanine iodide).
The method describes the detection of a violation of the membrane potential of mitochondria in individual cells. It is known that the loss of mitochondrial membrane potential precedes apoptosis and necrosis caused by chemical hypoxia. The lipophilic cationic dye JC-1 exhibits potential-dependent uptake in mitochondria and is a simple fluorescent technique for distinguishing between healthy and apoptotic cells. In healthy cells, the negative charge created by the intact potential of the mitochondrial membrane promotes the accumulation of JC-1 in the mitochondrial matrix. At high concentrations, JC-1 aggregates and turns red. In apoptotic cells, the mitochondrial potential collapses and JC-1 is localized in the cytosol in its monomeric green fluorescent form.
Recommended products
Lysis 1 - lysis buffer, 100 ml
Lysis 1 is used when working on the NucleoCounter NC-202 instrument. The assay allows for cell counting in samples containing cell clumps or aggregates.
SKU: 910-0010
Reagent A100, volume 500 ml
Lysis buffer used to count the total number of cells with the NucleoCounter system.
SKU: 910-0003
Solution 18 (200 analyzes) AO / DAPI 1 ml
Solution 18 contains two different dyes: acridine orange, which stains the entire population of cells, and fluorescent DAPI, which stains non-viable cells, respectively.
SKU: 910-3018
Solution 10 Lysis buffer, 100 ml
Used in two-step cell cycle assays.
SKU: 910-3010
Cell lysis buffer Reagent Y100, 500 ml
Reagent to determine the total number of yeast cells in a sample using the YC-100 ™ and NC-3000 ™.
SKU: 910-0300
Solution 17 Blood lysis buffer, 25 ml
Used in determining the viability and concentration of leukocytes in samples containing red erythrocytes.
SKU: 910-3017
Solution 3 DAPI Staining solution, 25 ml
The solution is used to analyze cells on laboratory analyzers NC-250 and NC-3000.
SKU: 910-3003
Solution 20 VitaBright-48, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3020
Lysis / Dilution Buffer - Reagent S100
Used in determining the total number of mammalian sperm cells.
SKU: 910-0101
Solution 11 Stabilization buffer, 100 ml
Buffer for pH stabilization in two-step cell cycle assays.
SKU: 910-3011
Solution 5 VB-48 PI-AO (propidium iodide - acridine orange)
The solution is used in the analysis of cell viability on a laboratory cytometer NC-3000.
SKU: 910-3005
Solution 2 Propidium Iodide (PI) Staining Solution 25 ml
Used for cell cycle analysis of fixed cells when used with the NucleoCounter 250 and 3000 laboratory analyzers.
SKU: 910-3002
Solution 12 DAPI (4’,6-diamidino-2-phenylindole) 1ml
DAPI fluorescent dye.
SKU: 910-3012
Solution 13 AO - DAPI 1ml
Solution for determining viability and counting cells using NC-Slides and NC-3000 analyzer.
SKU: 910-3013
Solution 6 VB-48 propidium iodide (PI) 1 ml
The solution is used for the analysis of cell viability.
SKU: 910-3006
Solution 8 DAPI dye in PBS (phosphate buffered saline), 25 ml
DAPI dye is used for routine staining of nuclei in flow cytometry, cell imaging and fluorescence microscopy. DAPI dye is available as a ready-to-use solution.
SKU: 910-3008
Solution 19 VitaBright-43, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3019
Reagent B, 500 ml
Buffer for pH stabilization during cell analysis.
SKU: 910-0002
Recommended products
Solution 2 Propidium Iodide (PI) Staining Solution 25 ml
Used for cell cycle analysis of fixed cells when used with the NucleoCounter 250 and 3000 laboratory analyzers.
SKU: 910-3002
Lysis 1 - lysis buffer, 100 ml
Lysis 1 is used when working on the NucleoCounter NC-202 instrument. The assay allows for cell counting in samples containing cell clumps or aggregates.
SKU: 910-0010
Solution 6 VB-48 propidium iodide (PI) 1 ml
The solution is used for the analysis of cell viability.
SKU: 910-3006
Solution 11 Stabilization buffer, 100 ml
Buffer for pH stabilization in two-step cell cycle assays.
SKU: 910-3011
Cell lysis buffer Reagent Y100, 500 ml
Reagent to determine the total number of yeast cells in a sample using the YC-100 ™ and NC-3000 ™.
SKU: 910-0300
Solution 17 Blood lysis buffer, 25 ml
Used in determining the viability and concentration of leukocytes in samples containing red erythrocytes.
SKU: 910-3017
Solution 13 AO - DAPI 1ml
Solution for determining viability and counting cells using NC-Slides and NC-3000 analyzer.
SKU: 910-3013
Solution 18 (200 analyzes) AO / DAPI 1 ml
Solution 18 contains two different dyes: acridine orange, which stains the entire population of cells, and fluorescent DAPI, which stains non-viable cells, respectively.
SKU: 910-3018