Solution 6 VB-48 propidium iodide (PI) 1 ml
SKU: 910-3006
Manufacturer: ChemoMetec
Availability: Order only
Solution 6 contains propidium iodide, which stains dead cells. In turn, VB-48 is a patented fluorophore that only fluoresces when bound to reduced thiols.
Used for measurements with the NucleoCounter 250 for viability analysis.
Description Recommended products
Description
Description
Viability Assay with NucleoCounter NC-250 System
The programmed method for the NucleoCounter NC-250 system allows the user to detect changes in the intracellular level of (reduced) thiols. Such changes can occur in apoptotic cells or cells undergoing other pathological processes. Since intracellular regenerative capacity is an indicator of overall health, this test provides a very simple and quick way to assess cell viability.
The cells to be tested are mixed with Solution 6. The solution contains two different reagents: propidium iodide (PI) for staining dead cells and VB-48, which stains viable cells depending on the intensity, which is dependent on the level of thiols in them. The high fluorescence intensity of a particular cell indicates that the cell has a high level of thiols such as GSH (glutathione).
The stained cells are immediately loaded onto NC-Slides: either 2-chamber NC-Slide A2 or 8-chamber NC-Slide A8. Samples are analyzed using the NucleoCounter NC-250 system. A fluorescence intensity histogram shows the distribution of thiol levels in all cells is displayed on the PC screen. By comparing histograms of treated cells with controls, a fraction of cells with low viability (eg, apoptotic or stressed cells) can be determined.
Recommended products
Solution 2 Propidium Iodide (PI) Staining Solution 25 ml
Used for cell cycle analysis of fixed cells when used with the NucleoCounter 250 and 3000 laboratory analyzers.
SKU: 910-3002
Reagent A100, volume 500 ml
Lysis buffer used to count the total number of cells with the NucleoCounter system.
SKU: 910-0003
Solution 10 Lysis buffer, 100 ml
Used in two-step cell cycle assays.
SKU: 910-3010
Solution 3 DAPI Staining solution, 25 ml
The solution is used to analyze cells on laboratory analyzers NC-250 and NC-3000.
SKU: 910-3003
Solution 7 cationic dye JC-1, 1 ml
A dye for determining the mitochondrial transmembrane potential of cells using the NucleoCounter NC-3000 laboratory analyzer.
SKU: 910-3007
Solution 19 VitaBright-43, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3019
Solution 8 DAPI dye in PBS (phosphate buffered saline), 25 ml
DAPI dye is used for routine staining of nuclei in flow cytometry, cell imaging and fluorescence microscopy. DAPI dye is available as a ready-to-use solution.
SKU: 910-3008
Solution 18 (200 analyzes) AO / DAPI 1 ml
Solution 18 contains two different dyes: acridine orange, which stains the entire population of cells, and fluorescent DAPI, which stains non-viable cells, respectively.
SKU: 910-3018
Lysis 1 - lysis buffer, 100 ml
Lysis 1 is used when working on the NucleoCounter NC-202 instrument. The assay allows for cell counting in samples containing cell clumps or aggregates.
SKU: 910-0010
Solution 5 VB-48 PI-AO (propidium iodide - acridine orange)
The solution is used in the analysis of cell viability on a laboratory cytometer NC-3000.
SKU: 910-3005
Solution 11 Stabilization buffer, 100 ml
Buffer for pH stabilization in two-step cell cycle assays.
SKU: 910-3011
Cell lysis buffer Reagent Y100, 500 ml
Reagent to determine the total number of yeast cells in a sample using the YC-100 ™ and NC-3000 ™.
SKU: 910-0300
912-0007 YC-100 test kit
The YC-100 test kit is intended to be used for routine checks of the NucleoCounter YC-100 yeast cell counter. It is recommended to check the instrument twice a year. The beads of the kit are fluorescent and will look like yeast cells in the image provided by the NucleoView software.
SKU: 912-0007
Reagent B, 500 ml
Buffer for pH stabilization during cell analysis.
SKU: 910-0002
Solution 17 Blood lysis buffer, 25 ml
Used in determining the viability and concentration of leukocytes in samples containing red erythrocytes.
SKU: 910-3017
Solution 12 DAPI (4’,6-diamidino-2-phenylindole) 1ml
DAPI fluorescent dye.
SKU: 910-3012
Solution 13 AO - DAPI 1ml
Solution for determining viability and counting cells using NC-Slides and NC-3000 analyzer.
SKU: 910-3013
Solution 20 VitaBright-48, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3020
Lysis / Dilution Buffer - Reagent S100
Used in determining the total number of mammalian sperm cells.
SKU: 910-0101
Related products
NucleoCounter NC-250 Automatic Cell Analyzer
The NucleoCounter® NC-250 ™ is an automated cell analyzer that uses fluorescence imaging technology to characterize cell properties.
SKU: 970-0251
Slides NC-Slide A2 ™
ChemoMetec bicameral slides (slides) made of high quality glass. Used with the NC-250 and NC-3000 analyzer models.
SKU: 942-0001
Slides NC-Slide A8 ™
ChemoMetec 8 chambers slides made of high quality glass. Used with the NC-250 and NC-3000 analyzer models.
SKU: 942-0003
Show more
Recommended products
Solution 8 DAPI dye in PBS (phosphate buffered saline), 25 ml
DAPI dye is used for routine staining of nuclei in flow cytometry, cell imaging and fluorescence microscopy. DAPI dye is available as a ready-to-use solution.
SKU: 910-3008
Solution 11 Stabilization buffer, 100 ml
Buffer for pH stabilization in two-step cell cycle assays.
SKU: 910-3011
912-0007 YC-100 test kit
The YC-100 test kit is intended to be used for routine checks of the NucleoCounter YC-100 yeast cell counter. It is recommended to check the instrument twice a year. The beads of the kit are fluorescent and will look like yeast cells in the image provided by the NucleoView software.
SKU: 912-0007
Solution 5 VB-48 PI-AO (propidium iodide - acridine orange)
The solution is used in the analysis of cell viability on a laboratory cytometer NC-3000.
SKU: 910-3005
Solution 20 VitaBright-48, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3020
Solution 13 AO - DAPI 1ml
Solution for determining viability and counting cells using NC-Slides and NC-3000 analyzer.
SKU: 910-3013
Solution 17 Blood lysis buffer, 25 ml
Used in determining the viability and concentration of leukocytes in samples containing red erythrocytes.
SKU: 910-3017
Solution 10 Lysis buffer, 100 ml
Used in two-step cell cycle assays.
SKU: 910-3010
Lysis / Dilution Buffer - Reagent S100
Used in determining the total number of mammalian sperm cells.