Reagent Y100 Yeast Cell Lysis Buffer is suitable for sample preparation of most yeast cell suspensions. It is very effective and usually allows you to instantly lyse yeast cells in suspension.
Description Specifications Recommended products
Description
Description
The Y100 reagent is used to disrupt the plasma membranes of yeast cells, making the nuclei susceptible to staining with propidium iodide (PI).
It is recommended to use a 1:10 ratio of sample volume to Y100 reagent (for example, 50 ml of sample and 450 ml of Y100 reagent).
If the sample medium is a colored solution such as beer or wine, dilution may be required before using the Y100 reagent so that the color does not affect the fluorescence intensity detected from the cells.
Used to determine the total number of yeast cells in a sample using the ChemoMetec YC-100 ™ and NC-3000 ™ instruments.
Specifications
Parameters | Yeast |
Recommended products
Solution 17 Blood lysis buffer, 25 ml
Used in determining the viability and concentration of leukocytes in samples containing red erythrocytes.
SKU: 910-3017
Lysis / Dilution Buffer - Reagent S100
Used in determining the total number of mammalian sperm cells.
SKU: 910-0101
Solution 18 (200 analyzes) AO / DAPI 1 ml
Solution 18 contains two different dyes: acridine orange, which stains the entire population of cells, and fluorescent DAPI, which stains non-viable cells, respectively.
SKU: 910-3018
Solution 5 VB-48 PI-AO (propidium iodide - acridine orange)
The solution is used in the analysis of cell viability on a laboratory cytometer NC-3000.
SKU: 910-3005
Solution 3 DAPI Staining solution, 25 ml
The solution is used to analyze cells on laboratory analyzers NC-250 and NC-3000.
SKU: 910-3003
Solution 8 DAPI dye in PBS (phosphate buffered saline), 25 ml
DAPI dye is used for routine staining of nuclei in flow cytometry, cell imaging and fluorescence microscopy. DAPI dye is available as a ready-to-use solution.
SKU: 910-3008
Solution 6 VB-48 propidium iodide (PI) 1 ml
The solution is used for the analysis of cell viability.
SKU: 910-3006
912-0007 YC-100 test kit
The YC-100 test kit is intended to be used for routine checks of the NucleoCounter YC-100 yeast cell counter. It is recommended to check the instrument twice a year. The beads of the kit are fluorescent and will look like yeast cells in the image provided by the NucleoView software.
SKU: 912-0007
Reagent A100, volume 500 ml
Lysis buffer used to count the total number of cells with the NucleoCounter system.
SKU: 910-0003
Solution 19 VitaBright-43, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3019
Solution 12 DAPI (4’,6-diamidino-2-phenylindole) 1ml
DAPI fluorescent dye.
SKU: 910-3012
Lysis 1 - lysis buffer, 100 ml
Lysis 1 is used when working on the NucleoCounter NC-202 instrument. The assay allows for cell counting in samples containing cell clumps or aggregates.
SKU: 910-0010
Reagent B, 500 ml
Buffer for pH stabilization during cell analysis.
SKU: 910-0002
Solution 13 AO - DAPI 1ml
Solution for determining viability and counting cells using NC-Slides and NC-3000 analyzer.
SKU: 910-3013
Solution 7 cationic dye JC-1, 1 ml
A dye for determining the mitochondrial transmembrane potential of cells using the NucleoCounter NC-3000 laboratory analyzer.
SKU: 910-3007
Solution 10 Lysis buffer, 100 ml
Used in two-step cell cycle assays.
SKU: 910-3010
Solution 20 VitaBright-48, 100 μl
Solution for cytometric profiling of apoptosis and other pathological processes.
SKU: 910-3020
Solution 2 Propidium Iodide (PI) Staining Solution 25 ml
Used for cell cycle analysis of fixed cells when used with the NucleoCounter 250 and 3000 laboratory analyzers.
SKU: 910-3002
Solution 11 Stabilization buffer, 100 ml
Buffer for pH stabilization in two-step cell cycle assays.
SKU: 910-3011
Recommended products
Solution 5 VB-48 PI-AO (propidium iodide - acridine orange)
The solution is used in the analysis of cell viability on a laboratory cytometer NC-3000.
SKU: 910-3005
Solution 17 Blood lysis buffer, 25 ml
Used in determining the viability and concentration of leukocytes in samples containing red erythrocytes.
SKU: 910-3017
Solution 6 VB-48 propidium iodide (PI) 1 ml
The solution is used for the analysis of cell viability.
SKU: 910-3006
Solution 10 Lysis buffer, 100 ml
Used in two-step cell cycle assays.
SKU: 910-3010
Lysis 1 - lysis buffer, 100 ml
Lysis 1 is used when working on the NucleoCounter NC-202 instrument. The assay allows for cell counting in samples containing cell clumps or aggregates.
SKU: 910-0010
Solution 13 AO - DAPI 1ml
Solution for determining viability and counting cells using NC-Slides and NC-3000 analyzer.
SKU: 910-3013
Lysis / Dilution Buffer - Reagent S100
Used in determining the total number of mammalian sperm cells.
SKU: 910-0101
Solution 8 DAPI dye in PBS (phosphate buffered saline), 25 ml
DAPI dye is used for routine staining of nuclei in flow cytometry, cell imaging and fluorescence microscopy. DAPI dye is available as a ready-to-use solution.
SKU: 910-3008