Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Titration Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

Dissolved Oxygen Reagent Accuvac® Ampules, 0.3 - 15.0 mg/L O2

hach-ampuly-2515025-s-reagentom-na-rastvorennyy-kislorod.jpeg

SKU: 2515025

Manufacturer: Hach

Availability: Order only

Order Add to comparison

The vials contain the exact amount of reagent for one test and can be used as a measuring cuvette.
For the determination of dissolved oxygen by Hach methods 8166 and 8333.
Range: 0.3 - 15.0 or 1 - 40 mg / L O2.
The package contains 25 ampoules.


Description

Description

Parameter: Dissolved oxygen

Range: high 0.3 - 15.0 or 1 - 40 mg / l O2.

Application: For water and waste water

Description of the method [high range]: The AccuVac Ampul for the determination of high concentrations of dissolved oxygen contains a reagent sealed under vacuum in a glass ampoule. When the AccuVac Ampul is opened in a sample containing dissolved oxygen, the solution turns yellow and turns purple.The purple color development is proportional to the concentration of dissolved oxygen.

Fast

Accuvac® ampoules deliver fast results. Immerse the tip of the ampoule into the sample and press gently so that its tip breaks off, the ampoule will be filled with the sample under the action of vacuum and the contents will be mixed. The color of the content is assessed visually or photometrically.

Easy

It is not necessary to measure the amount of sample or reagent. The evacuated ampoules draw the correct sample volume, you get reliable results with minimal effort.

Always accurate results

Optical grade vacuum vials provide accurate measurements and reagent stability. Ampoules are reagent containers and photometric measuring cells.

Specifications

Specifications

Application areaTest kits, Wastewater, Reagents, Food production, Treatment facilities, Beverages, Laboratory analysis
TypeReagents in ampoules
IndustryPulp and paper, Power generation, Chemical, Food and Beverage, Municipal
ParametersDissolved oxygen
Measurement Range0.3 - 15.0 mg/L O2
CompatibilityDR6000, DR1900, DR900, DR3900, DR300 (Dissolved oxygen)
MethodHRDO
Number of tests25
Measurement Range (2)1.0 - 40.0 mg/L O2
Video
Downloads

Downloads

Dissolved Oxygen, HRDO Method 8166, HR AccuVac® Ampuls
Recommended products

Recommended products

Dissolved Oxygen Reagent Accuvac® Ampules, 6-800 µg/L O2

Dissolved Oxygen Reagent Accuvac® Ampules, 6-800 µg/L O2

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2501025 ampoules contain a reagent for the determination of Dissolved Oxygen in low range 6-800 µg/L O2

SKU: 2501025

View product Compare

Fluoride Reagent, Accuvac® Ampules, 0.02 - 2.00 mg/L F-

Fluoride Reagent, Accuvac® Ampules, 0.02 - 2.00 mg/L F-

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2506025 ampoules contain a reagent for the determination of Fluoride 0.02 - 2.00 mg/L F-.

SKU: 2506025

View product Compare

Ozone Reagent, Accuvac® Ampules HR, 0.01-1.5 mg/L O3

Ozone Reagent, Accuvac® Ampules HR, 0.01-1.5 mg/L O3

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2517025 ampoules contain a reagent for the determination of Ozone in the high range of 0.01-1.5 mg/L O3

SKU: 2518025

View product Compare

Free Chlorine Reagent, Accuvac® Ampules, DPD

Free Chlorine Reagent, Accuvac® Ampules, DPD

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2502025 ampoules contain a reagent for the determination of free chlorine 0.02–2.00 mg / l Cl2.

SKU: 2502025

View product Compare

Nitrate Reagent, Accuvac® Ampules 0.3-30.0 or 0.1-10.0 mg/L NO3-N

Nitrate Reagent, Accuvac® Ampules 0.3-30.0 or 0.1-10.0 mg/L NO3-N

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2511025 ampoules contain a reagent for the determination of Nitrate 0.3-30.0 or 0.1-10.0 mg/L NO3-N.

SKU: 2511025

View product Compare

Ozone Reagent, Accuvac® Ampules MR, 0.01-0.75 mg/L O3

Ozone Reagent, Accuvac® Ampules MR, 0.01-0.75 mg/L O3

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2517025 ampoules contain a reagent for the determination of Ozone in the mid range of 0.01 - 0.75 mg / l O3.

SKU: 2517025

View product Compare

Standard Solution, Manganese, 10 mg/L Mn (NIST), PourRite Ampoules

Standard Solution, Manganese, 10 mg/L Mn (NIST), PourRite Ampoules

Used to check the accuracy of the analysis when determining manganese in a water sample.

SKU: 2605820

View product Compare

ORP calibration solution in ampoules (Light's solution)

ORP calibration solution in ampoules (Light's solution)

Light's solution in ampoules for calibration of ORP meters. The package contains 20 ampoules of 20 ml.

SKU: 2612520

View product Compare

Ozone Reagent, Accuvac® Ampules LR, 0.01-0.25 mg/L O3

Ozone Reagent, Accuvac® Ampules LR, 0.01-0.25 mg/L O3

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2516025 ampoules contain a reagent for the determination of Ozone in the low range of 0.01 - 0.25 mg / l O3.

SKU: 2516025

View product Compare

FerroVer Iron Reagent, Accuvac® Ampules 0.02 - 3.00 mg/L Fe

FerroVer Iron Reagent, Accuvac® Ampules 0.02 - 3.00 mg/L Fe

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2507025 ampoules contain a reagent for the determination of Iron 0.02 - 3.00 mg/L Fe.

SKU: 2507025

View product Compare

 Total Chlorine / Bromine / Iodine Reagent, Accuvac® Ampules, DPD

Total Chlorine / Bromine / Iodine Reagent, Accuvac® Ampules, DPD

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2502025 ampoules contain a reagent for the determination of total chlorine 0.02–2.00 mg / l Cl2; Bromine 0.05 - 4.50 mg / L Br2 and Iodine 0.07 - 7.00 mg / L I2.

SKU: 2503025

View product Compare

Standard Solution, Manganese, 25 mg/L Mn (NIST), PourRite Ampoules

Standard Solution, Manganese, 25 mg/L Mn (NIST), PourRite Ampoules

Used to check the accuracy of the analysis when determining manganese in a water sample.

SKU: 2112820

View product Compare

PhosVer Phosphate, Accuvac® Ampules 0.02-2.50 mg/L PO4

PhosVer Phosphate, Accuvac® Ampules 0.02-2.50 mg/L PO4

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2508025 ampoules contain a reagent for the determination of Phosphate 0.02-2.50 mg/L PO4

SKU: 2508025

View product Compare

Copper Reagent, Accuvac® Ampules 0.04 - 5.00 mg/L Cu

Copper Reagent, Accuvac® Ampules 0.04 - 5.00 mg/L Cu

Test set of sealed glass vials (25 pcs.) With the exact amount of reagent in a vacuum for performing one test. Accuvac® 2504025 ampoules contain a reagent for the determination of copper 0.04 - 5.00 mg/L Cu.

SKU: 2504025

View product Compare

Related products

DR300 Pocket Colorimeter, Dissolved Oxygen

DR300 Pocket Colorimeter, Dissolved Oxygen

Hach DR 300 pocket single-parameter colorimeter for measuring Dissolved Oxygen consentration in water. Measuring range: 0.2 - 10.0 mg/L O2.

SKU: LPV445.99.03110

View product Compare


Show more