N-ISE sc immersion nitrate probe
SKU: LXV440.99.20001, LXV440.99.20011
Manufacturer: Hach
Availability: Order only
The N-ISE sc immersion sensor is designed for continuous determination of nitrate concentration 0 - 1000 mg/l NO3-N in wastewater. It works without reagents and does not require further sample processing. Measurements are carried out directly in the medium using an ion-selective electrode sensitive to NO3- nitrate ions.
Delivery set: sensor, cartridge, user manual.
An SC series digital controller is required for power supply, data transmission and processing (available to order separately).
Description Specifications Recommended products Accessories
Description
Description
Determining the concentration of nitrates is critical to effectively control the nitrification process and addition of exactly the right amount of carbon. The N-ISE sc submersible sensor contains ion-selective electrodes for continuous measurements in the tank. No reagents or sample preparation required. The automatic compensation for chloride influences is a big advantage. The built-in pHD reference element ensures long-term stability of the measured values.
The only replacement part of the sensor is the cartridge (order number LZY694). The sensor cartridge consists of:
- ion-selective electrodes for nitrate and chloride (compensation electrode for nitrate - cross-sensitivity between nitrate and chloride is automatically eliminated)
- pHD reference system
- temperature sensor
The electrodes are perfectly calibrated at the factory. If necessary, matrix correction can be performed at any time. The compact CARTRICAL plus cartridge replaces the usual three separate electrodes and maximizes ease of use. The compact cartridge eliminates the tedious handling and calibration of individual electrodes: just remove the old cartridge and insert a new one. After replacing the cartridge, the probe is immediately ready for use. The manufacturer recommends replacing the cartridge only once a year. An optional cleaning unit for automatic cleaning of the sensor cartridge membranes can be ordered separately.
The low cost of the N-ISE sc sensor makes it possible to reliably measure the concentration of nitrates even in small and medium-sized wastewater treatment plants.
- LXV440.99.20001 - N-ISE sc ISE nitrate sensor (submersible) with RFID technology, measuring range 0 - 1000 mg/l NO3-N, Cl-; cable 10 m.
- LXV440.99.20011 - N-ISE sc ISE nitrate sensor (submersible) without RFID technology, measuring range 0 - 1000 mg/l NO3-N, Cl-; cable 10 m.
N-ISE sc Hach sensor specifications
- Measurement method potentiometric ion-selective measurement
- Measuring range 0 - 1000 mg/l NO3-N, 0 - 1000 mg/l Cl- (compensation)
- Lower detection limit 0.2 mg/l NO3-N
- Accuracy 5% or ± 0.2 mg / l (with standard solution)
- Response time < 3 min.
- Sensor cartridge with CARTRICAL technology, 12 months service life
- Calibration with Cartrical plus technology: automatic import of factory calibration data from the cartridge to the sensor using RFID; 1- and 2-point matrix correction
- Operating temperature range air: from -20 to +45 °C, water: from +2 to +40 °C
- pH range 5 - 9
- Immersion depth 0.3 - 3.0 m
- Material stainless steel, PVDF (Ryton®)
- Dimensions, weight 84.5 mm x 320 mm (Ø x L), approx. 2.4 kg
- Connection Hach Lange SC series controllers
Specifications
Application area | Wastewater, Treatment facilities, Process control |
Type | Industrial |
Industry | Municipal |
Parameters | Nitrate |
Measurement Range | 0 - 1000 mg/L NO3-N |
Measurement method | ISE |
Recommended products
1200-S sc Digital pH sensor for SC controller
Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.
SKU: LXV426.99.10001
FP 360 sc sensor for detecting petroleum products
The FP 360 sc digital fluorescent UV sensor is designed to detect oil products in the water.
SKU: LXV441.99.22101
Ammonium analyzers Hach Amtax sc
High-precision industrial device for the determination of ammonium in water, waste water and activated sludge. Amtax sc measures ammonium concentration using a gas selective electrode (GSE). Designed for outdoor or indoor installation.
SKU: LXV421.99.???1
Orthophosphate analyzer PHOSPHAX sc
With detection limits ranging from 0.05 mg/L to 50 mg/L, the Phosphax sc phosphate analyzer can be used anywhere in the wastewater treatment process, from water entering the treatment plant or starting a phosphorus removal process where phosphate levels can be high, to discharged wastewater with a low level of phosphate.
SKU: LXV422.99.13001
AN-ISE sc immersion ammonium and nitrate ion-selective probe
The Hach AN-ISE sc digital combination ammonium and nitrate sensor performs continuous direct measurements using an ion selective electrode. No reagents or sample preparation required. Automatic and simultaneous potassium and chloride compensation. Easy handling and low maintenance thanks to the Cartrical plus sensor cartridge with five electrodes.
SKU: LXV440.99.00001
A-ISE sc NH4-N Immersion Ion Selective Probe
The digital ion selective probe A-ISE sc Hach is designed to determine the concentration of ammonium directly in the medium. No calibration required. Automatic potassium compensation. The sensor is easy to handle. Low maintenance thanks to the cartridge system. The A-ISE sc is particularly economical in terms of installation and operation, even in small wastewater treatment plants.
SKU: LXV440.99.10001, LXV440.99.10011
Accessories
SC200 Digital 2-channel controller
HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.
SKU: LXV404.99.00551
SC1000 Probe module for 4 sensors
Universal digital controller SC1000, for connecting up to 4 SC sensors with 1 analogue output card with 4 x 0 / 4-20 mA output.
SKU: LXV400.99.00121
Replacement cartridge for AN-ISE sc, A-ISE sc and N-ISE sc probes
Cartridge for process Hach Lange ion-selective sensors for the determination of ammonium and nitrates.
SKU: LZY694
SC4500 digital controller
The SC4500 is a dual channel controller for digital analytical devices (such as sensors and analyzers). The controller shows sensor measurements and other data on the display, can transmit analog and digital signals, and can also interact with other devices and control them through outputs and relays.
SKU: LXV525.99C11551
Recommended products
1200-S sc Digital pH sensor for SC controller
Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.
SKU: LXV426.99.10001
FP 360 sc sensor for detecting petroleum products
The FP 360 sc digital fluorescent UV sensor is designed to detect oil products in the water.
SKU: LXV441.99.22101
Ammonium analyzers Hach Amtax sc
High-precision industrial device for the determination of ammonium in water, waste water and activated sludge. Amtax sc measures ammonium concentration using a gas selective electrode (GSE). Designed for outdoor or indoor installation.
SKU: LXV421.99.???1
Orthophosphate analyzer PHOSPHAX sc
With detection limits ranging from 0.05 mg/L to 50 mg/L, the Phosphax sc phosphate analyzer can be used anywhere in the wastewater treatment process, from water entering the treatment plant or starting a phosphorus removal process where phosphate levels can be high, to discharged wastewater with a low level of phosphate.
SKU: LXV422.99.13001
AN-ISE sc immersion ammonium and nitrate ion-selective probe
The Hach AN-ISE sc digital combination ammonium and nitrate sensor performs continuous direct measurements using an ion selective electrode. No reagents or sample preparation required. Automatic and simultaneous potassium and chloride compensation. Easy handling and low maintenance thanks to the Cartrical plus sensor cartridge with five electrodes.
SKU: LXV440.99.00001
A-ISE sc NH4-N Immersion Ion Selective Probe
The digital ion selective probe A-ISE sc Hach is designed to determine the concentration of ammonium directly in the medium. No calibration required. Automatic potassium compensation. The sensor is easy to handle. Low maintenance thanks to the cartridge system. The A-ISE sc is particularly economical in terms of installation and operation, even in small wastewater treatment plants.