Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Titration Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

DR/Check Absorbance Standard Kit (Set of 4)

hach-2763900-dr-check-nabor-standartov.jpg2763900 hach kit for checking spectrophotometerinstruction for 2763900

SKU: 2763900

Manufacturer: Hach

Availability: Order only

Order Add to comparison

The DR/Check kit contains four vials (25 mm glass cuvettes) filled with gels at increasing Absorbance values: blank and three absorbance standards.

Used to check the response of a colorimeter or spectrophotometer regardless of sample parameters or chemical composition at specific wavelengths: 420, 520, 560 and 610 nm.

Compatible with any colorimeter or spectrophotometer that can accommodate a 25mm round cuvette and read the four wavelengths indicated.

Shelf life: 16 months upright at room temperature.


Description

Description

The kit is specially designed for use with the DR800 and DR900 colorimeters, but can also be used with any instrument that can read the four wavelengths indicated on the kit box (420, 520, 560 and 610 nm). These standards are the same as standard glass neutral density filters.

When using DR/Check (2763900), use the Absorption mode on your instrument. Set the instrument to a specific wavelength, zero with a blank standard from this kit, and read the absorbance of each of the three standards. The standards are supplied with a certificate stating what the absorption values should be at certain wavelengths.

Periodic measurement of the optical density of the standards from the DR/Check set will ensure that there are no significant changes in the response of the instrument.

It is important to remember that when test results are out of tolerance, this does not indicate a specific problem. Instrument response is a comprehensive measure that encompasses all possible sources of the error. The DR/Check can confirm whether there has been a change in the response of the instrument, but cannot determine the reason for the change.

Specifications

Specifications

Application areaLaboratory analysis
CompatibilityDR6000, DR1900, DR900, DR3900, DR5000, DR2800, DR3800
Recommended products

Recommended products

SpecCheck Chlorine Standards Kit 0 - 2.0 mg/L Cl2

SpecCheck Chlorine Standards Kit 0 - 2.0 mg/L Cl2

SpecCheck Gel Standard Kit, Concentration 0 - 2.0 mg/L Cl2.

SKU: 2635300

View product Compare

Chlorine SpecCheck Secondary Standard Set DPD Method - Medium Range

Chlorine SpecCheck Secondary Standard Set DPD Method - Medium Range

SpecCheck Set of Secondary Standards for Chlorine Determination (Mid Range) by DPD Method. Contains an empty cuvette and 3 color gel cuvettes with a Cl2 concentration of ~ 0.2, ~ 1.6 and ~ 2.7 mg/L.

SKU: 2980500

View product Compare

SpecCheck Set of Secondary Standards for Chlorine, DPD Method

SpecCheck Set of Secondary Standards for Chlorine, DPD Method

SpecCheck set of secondary standards for chlorine determination (high range) by DPD method. Contains a cuvette with a blank test and 3 cuvettes with color gels of different concentrations.

SKU: 2893300

View product Compare

SpecCheck Secondary Standard Kit, Ozone 0 - 0.75 mg/L O3

SpecCheck Secondary Standard Kit, Ozone 0 - 0.75 mg/L O3

Ready-to-use gel standards (set of 4 vials) for instrument verification in the laboratory and in the field.

SKU: 2708000

View product Compare

SpecCheck Secondary Gel Standard Kit - Fluoride, 0-2.0 mg/L F-

SpecCheck Secondary Gel Standard Kit - Fluoride, 0-2.0 mg/L F-

Ready-to-use gel standards (set of 4 vials) for instrument verification in the laboratory and in the field.

SKU: 2712500

View product Compare

Recommended products