Test kit AC-6 for acidity determination

SKU: 222301
Manufacturer: Hach
Availability: Order only
The AC-6 set includes:
- volumetric sample tube
- mixing bottle
- reagents (see Accessories tab)
- instructions
- carrying case
Description Specifications Recommended products Accessories
Description
Description
Acidity test recommendations
The presence of chlorine in the water sample may slightly interfere with the test. Up to 50 mg/L chlorine can be removed with 0.1 N. sodium thiosulfate solution, cat. No. 323-37. This solution is not included in the kit. Add one drop of 0.1N sodium thiosulfate solution to the sample before adding the indicator. Over-agitation of the sample should be avoided to prevent the loss of dissolved gases such as carbon dioxide, hydrogen sulfide, or ammonia.
Free Acidity Test - High Range (0 - 400 mg/L CaCO3)
- Fill the volumetric tube with sample water. Pour the contents into a mixing bottle.
- Add 1 sachet of reagent (94399) to the mixing container and shake to mix.
- If the water turns gray-blue, blue, or green, the free acidity is zero.
- If the water turns pink, add Sodium Hydroxide Standard Solution (2349332) dropwise while holding the pipette vertically. Count each drop as you add. Mix the sample after each drop. Continue adding drops until the water turns gray-blue.
- The free acidity of the water, expressed in mg/L CaCO3, is equal to the number of drops of sodium hydroxide standard solution added multiplied by 20.
Acidity determination - Low range (0 - 100 mg/L CaCO3)
- Fill the mixing bottle with sample up to the 23 ml mark.
- Add 1 sachet of reagent (94399) to the mixing container and shake to mix.
- If the water turns gray-blue, blue, or green, the acidity is zero.
- If the water turns pink, add Sodium Hydroxide Standard Solution (2349332) dropwise while holding the pipette vertically. Count each drop as you add. Stir the mixing bottle after each drop. Continue adding drops until the water turns gray-blue.
- The acidity of water in mg/L, as calcium carbonate (CaCO3), is determined by multiplying the added number of drops of a standard sodium hydroxide solution by 5.
Step-by-step determination of total acidity (0 - 400 mg/L CaCO3)
- Fill a volumetric tube with a sample of water. Pour the contents into a mixing container.
- Add one drop of Phenolphthalein Indicator Solution (189736) to the mixing bottle and shake to mix.
- If the water turns pink, the total acidity is zero.
- If the water remains colorless, add sodium hydroxide standard solution (2349332) dropwise, holding the pipette vertically. Count each drop as you add. Stir the mixing bottle after each drop. Continue adding drops until the sample is slightly pink.
- The acidity of the water, expressed in mg/L as CaCO3, is equal to the number of drops of sodium hydroxide standard solution used, multiplied by 20.
Specifications
| Application area | Environmental monitoring, Wastewater, Treatment facilities, Laboratory analysis, Process control |
| Industry | Municipal |
| Parameters | Acidity |
| Measurement Range | 5 - 100 mg/L CaCO3 |
| Measurement method | drop count titration |
| Method | Sodium hydroxide |
| Number of tests | 100 |
Recommended products
Hach pH and total acidity titration set: beer, soft drinks, juices, energy drinks
The application pack (no reagents) includes an Intellical pH combination probe, syringe, all necessary accessories, and preprogrammed methods on a USB stick.
SKU: AP0025.AT1102
SKU: 1340-2702
SKU: DULCOTRANS
Digital titrator reagent kit, chloride 10 - 8000 mg/L Cl
Titrimetric determination of chlorides in waste water by the method of mercury nitrate (method Hach 8206).
SKU: 2272600
SKU: TitroLine 5000
SKU: 1340-6332
Hardness test kit (total / calcium), model HA-4P
Test kit for determination of total and calcium hardness by drop count titration / EDTA. Magnesium hardness can be calculated from the difference in the values obtained; range 20 - 400 mg/l CaCO3, 100 tests.
SKU: 145701
SKU: 1340-5434
SKU: 1340-6201
Test kit CA-23, carbon dioxide
Set for the determination of carbon dioxide by drop count titration in the range of 1.25 - 25, 2 - 40 and 5 - 100 mg/L CO2.
SKU: 143601
SKU: DULCOSMOSE SW
SKU: von Taine
SKU: 1601-0048-02
SKU: 1340-1620
Test kit, alkalinity, model AL-DT
Test kit, alkalinity; range 10 - 4000 CaCO3 mg / L.
SKU: 2063700
SKU: Bello Zon CDKd
SKU: ORLITA MH
SKU: 1340-6621
SKU: Bello Zon CDVd
SKU: HI-98509
Digital Titrator with plastic case
Manual titrator in plastic case for fast and accurate titration.
SKU: 1690001
SKU: EXTRONIC
SKU: ORLITA Evolution
Test kit, total chlorine, model CN-DT, 20 - 2000 mg/L
Test kit, total chlorine; range 20 - 2000 mg/L Cl2.
SKU: 2471100
Accessories
Bromcresol green - methyl red indicator, powder pillows, 100 pieces
Powder Pillows for titration (alkalinity).
SKU: 94399
Phenolphthalein indicator solution; 1 g/L, 15 ml
Solution for use in titration.
SKU: 189736
Standard solution, sodium hydroxide, 0.035 N, 100 ml
Solution for determining the acidity of a water sample.
SKU: 2349332
Recommended products
SKU: DULCOCLEAN UF
Digital titrator reagent kit, chloride 10 - 8000 mg/L Cl
Titrimetric determination of chlorides in waste water by the method of mercury nitrate (method Hach 8206).
SKU: 2272600
SKU: ORLITA Evolution mikro
Hach titration application kit: pH / alkalinity and conductivity of water
Hach accessory kit (without reagents) for measuring pH, alkalinity and conductivity in waste water.
SKU: AP0002.AT1102
SKU: HYDRO API 675
SKU: MAKRO M5Ka
Digital Titrator with plastic case
Manual titrator in plastic case for fast and accurate titration.
SKU: 1690001
SKU: 150703
SKU: LSN 2




