Silica Reagent Set, Rapid Liquid, 3-1000 µg/L SiO2

SKU: 2678500
Manufacturer: Hach
Availability: Order only
For the determination of silicon dioxide in the ultra-low range by the Heteropoly blue method.
Set includes: Molybdate 3 Reagent Solution, Citric Acid F Reagent Solution, Amino Acid Reagent Dilution Solvent and Amino Acid F Reagent Powder
Method Hach 8282.
Range: 3 - 1000 μg/L SiO2.
The volume of reagents is sufficient for 40 tests.
Description Specifications Downloads Recommended products
Description
Description
Hach reagent kit 2678500.
Parameter: Silicon Dioxide (Ultra Low Range)
Range: 3 - 1000 μg / L SiO2
Applications: For the determination of trace amounts of soluble silica (silicon dioxide) in pure and ultrapure water.
Method Description: A number of changes are required to adapt the low range silica method for trace level analysis in the ultra low range method. The use of a 1-inchPour-Thru Cell and liquid reagents is absolutely essential. Pour-Thru Cell increases the reproducibility of the optics and reduces the instability of readings that results from moving sample bottles. Liquid reagents provide more reproducible readings and a lower chance of blanks by eliminating the slight haze that can remain with powdered reagents.
The silica and phosphate in the sample react with molybdate ions under acidic conditions to form yellow silicomolybdic acid complexes and phosphomolybdic acid complexes. The addition of citric acid destroys phosphate complexes. The amino acid reagent F is then added to change the yellow silicomolybdic acid color to an intense blue that is proportional to the concentration of silica. The measurement wavelength is 815 nm for spectrophotometers (for the DR 1900 spectrophotometer: 800 nm).
Specifications
| Application area | Reagents, Food production, Drinking water, Brewing, Beverages |
| Type | Liquid reagents |
| Industry | Pharmaceutical, Power generation, Chemical, Food and Beverage |
| Parameters | Silicon |
| Measurement Range | 3 - 1000 µg/L SiO2 |
| Compatibility | DR6000, DR1900, DR3900 |
| Method | Heteropoly-blue |
| Number of tests | 250 |
| Quality control | 110649 |
Recommended products
Chlorine Dioxide Reagent Set, 0.01-1.00 mg/L ClO2
Hach reagents for the determination of chlorine dioxide. The volume of reagents is enough for 100 tests.
SKU: 2242300
ORP / Redox calibration solution (ZoBell's solution)
Standard solution for calibration and accuracy verification of ORP electrodes.
SKU: 2316949
HydraVer2 Hydrazine reagent solution, 4 - 600 µg/L, 100 mL
Hach reagents for the determination of hydrazine. Range: 4 - 600 μg / L N2H4. A volume of 100 ml is sufficient for 100 tests.
SKU: 179032
Total Trihalomethanes Plus Reagent Set (THM)
Hach reagent kit for the determination of trihalomethanes (THM) in the range of 10 - 600 μg/L CHCl3. The kit is enough to carry out 50 - 99 analyzes.
SKU: 2790800
Lovibond DPD 1 Buffer Solution
Solution for the photometric determination of free/total chlorine in water samples.
SKU: 471010, 471016, 471011
Chlorine, liquid DPD reagent set, 0.02-2.00mg/L Cl2
Hach reagents for the determination of Chlorine in the analysis of drinking, waste and process water, as well as for control and monitoring of product quality. The reagent volume is sufficient for approximately 100 tests. Range 0.02 - 2.00 mg/L Cl2
SKU: HPT310
Reagent for BioTector 4.0 N NaOH (sodium hydroxide)
Container (10, 20 liters) with a reagent for an industrial TOC analyzer.
SKU: 2563891, 2038062
Phenol red indicator solution, 6.5-8.5 pH, 50mL
Standardized for colorimetric pH determination. Specialist. class. Range: pH 6.5-8.5.
SKU: 2657512
Tannin & Lignin Reagent Set, 0.1-9.0 mg/L
Hach reagent kit for the determination of tannin and lignin in the range of 0.1 - 9.0 mg/l as tannic acid. The kit is enough for 100 analyzes.
SKU: 2244600
Reagent B for Phosphax sc LR Analyzer
Reagent for Hach Lange Low Range Orthophosphate Analyzer.
SKU: LCW957
Reagent for BioTector 1.8 N sulfuric acid, 80 mg/l MnSO4
Container with reagent for process TOC analyzer.
SKU: 25255061, 2563889
Reagent set for the total hardness test kit HA-71A
Replacement reagent kit for determination of total hardness by drop count titration with EDTA using the HA-71A test kit.
SKU: 2437800
PHOSPHAX sc LR analyzer cleaning solution C
LCW959 solution for online process low range orthophosphate analyzer.
SKU: LCW959
Reagent A for Phosphax sc LR Analyzer
Reagent for Hach Lange Low Range Orthophosphate Analyzer.
SKU: LCW956
Ferric ion solution
Solution for the colorimetric determination of chlorides in water by the mercury thiocyanate method.
SKU: 2212242
SKU: 8185550100
SKU: 2257249
SKU: 245032
Silica Reagent Set, Bulk Solution, 3 - 1000 µg/L SiO2
Hach reagent kit for the determination of silicon dioxide in the ultra-low range 3 - 1000 μg / l SiO2. The kit is enough for 100 analyzes.
SKU: 2553500
Chlorine Liquid DPD Reagent 0.02-2.0mg/L Cl2 free
Hach reagents for the determination of Free Chlorine in the low range by DPD method. The volume of reagents is enough for 100 tests.
SKU: HPT210
Standard solution, sodium hydroxide, 0.035 N, 100 ml
Solution for determining the acidity of a water sample.
SKU: 2349332
Hardness reagent kit, 4 - 1000 μg/L CaCO3
Determination of ultra-low level of water hardness by the chlorophosphonazo method.
SKU: 2603101
SKU: SR0222C
Recommended products
SKU: 8035280100
Formaldehyde Reagent Set, 3-500 µg/L CH2O
Hach reagents for the determination of Formaldehyde in water. Range: 3-500 μg / L CH2O. Number of tests - 100.
SKU: 2257700
Reagent kit Amtax sc with standard, for range 10 - 1000 mg/L NH4-N
LCW866 Reagent Kit for Oline Ammonium Analyzer with Standard Calibration Solutions.
SKU: LCW866
Molybdovanadate Reagent Solution (500mL) 0.3 - 45.0 mg/L PO4
Hach reagents for the determination of phosphate (ortho). Range: 0.3 - 45.0 mg/l PO4. Volume 500 ml. Number of analyzes - 250.
SKU: 2076049
Chlorine, liquid DPD reagent set, 0.02-2.00mg/L Cl2
Hach reagents for the determination of Chlorine in the analysis of drinking, waste and process water, as well as for control and monitoring of product quality. The reagent volume is sufficient for approximately 100 tests. Range 0.02 - 2.00 mg/L Cl2
SKU: HPT310
Phenolphthalein Indicator Solution, 5 g/L, 1 L (APHA)
PH indicator for use in titration.
SKU: 16253
LeadTrak™ Reagent Set, Fast Column Extraction Method
Hach reagents for the determination of lead. Range: 5 - 150 μg/L Pb.
SKU: 2375000
SKU: 58360
SKU: 1.04201.0100