CD-51 test kit includes:

  • two reagents (reagent 104399 and titrant 2349432)
  • deionized water
  • mixing bottle
  • measuring tube
  • dropper
  • instruction
  • case for carrying and storage

Description

Description

Chloride, found in almost all natural waters, affects the taste of water at concentrations above 250 mg/l. High levels inhibit plant growth, and many manufacturing processes must limit chloride concentrations. This test kit is a multi-range kit (500 - 10,000 mg/L Cl- and 5,000 - 100,000 mg/L Cl-) supplied with deionized water to dilute the sample. The kit is enough to run 100 tests.

Recommendations for working with the CD-51

  • Hold the pipette vertically over the sample. Do not let it touch the vial during titration.
  • Rinse tubes and vials with sample prior to testing. After the test, rinse the tubes and bottles with deionized water.
  • To record the test result as mg/L sodium chloride (NaCl), multiply the chloride result by 1.65.

Step-by-step determination of chloride in the range of 0 - 10,000 mg / l Cl-

  1. Fill the measuring tube with the sample.
  2. Transfer the sample to a mixing container.
  3. Add one pillow with Indicator (104399).
  4. Turn the mixing bottle left and right to mix.
  5. Add titrant (2349432) with silver nitrate drop by drop. Cap the bottle and shake vigorously after each drop. Count the drops until the color changes from yellow to reddish brown.
  6. If the precipitate is orange and the solution is yellow, repeat all steps with a new sample and shake the sample again.
  7. Multiply the total number of drops by 500 to get the result in mg/L.

Step-by-step determination of chloride in the range 0 - 100,000 mg / l Cl-

  1. Rinse the plastic pipette two or three times with sample water.
  2. Fill the pipette to the mark with the sample.
  3. Add the sample to the mixing bottle.
  4. Add deionized water to the mixing bottle until it is almost half full.
  5. Follow steps 3 - 6 from the previous instructions.
  6. Multiply the total number of drops by 5000 to get the result in mg/L.
Specifications

Specifications

Application areaTest kits, Drinking water, Laboratory analysis, Process control
IndustryEcology, Food and Beverage, Municipal
ParametersChloride
Measurement Range500 - 10000 mg/L Cl-
Measurement methoddrop count titration
Measurement Range (2)5000 - 100000 mg/L Cl-
Recommended products

Recommended products

Acidity Test Kit, Model AC-DT

Acidity Test Kit, Model AC-DT

Test kit, acidity;  range 10 - 4,000 mg / L CaCO3.

SKU: 2064000

View product Compare

Distillation unit UDK 129

Distillation unit UDK 129

The UDK 129 is a basic but powerful system for a variety of tests, including the measurement of various types of nitrogen (e.g. ammonia and protein Kjeldahl or direct alkaline distillation), as well as the analysis of substances such as phenols, volatile fatty acids, cyanide and alcohol.

SKU: UDK 129

View product Compare

SKU: Rotech Keg Filling Line Monitoring System

View product Compare

SKU: 1340-5430

View product Compare

SKU: 1340-6339

View product Compare

SKU: 1340-6623

View product Compare

SKU: 1340-5739

View product Compare

Hach Titration Kit: Total Hardness

Hach Titration Kit: Total Hardness

Hach accessory kit (without reagents) for determining the total water hardness.

SKU: AP0004.AT1112

View product Compare

SKU: 1340-6201

View product Compare

SKU: 1202009S

View product Compare

SKU: 710-2244

View product Compare

SKU: 1340-5415

View product Compare

SKU: 1601-0044

View product Compare

SKU: SPECTRA

View product Compare

SKU: CHLORINSITU IIa XL

View product Compare

Potentiometric titrator Titralab AT1122, 1 burette, 2 pumps

Potentiometric titrator Titralab AT1122, 1 burette, 2 pumps

Automatic potentiometric Hach titrator for fast and accurate titrations.

SKU: AT1122.82

View product Compare

SKU: 1601-0020

View product Compare

Hach Titration Kit: Ca / Mg Water Hardness (ISE)

Hach Titration Kit: Ca / Mg Water Hardness (ISE)

Set of accessories (without reagents) Hach for determination of calcium and magnesium hardness of water.

SKU: AP0003.AT1112

View product Compare

SKU: Bello Zon CDKd

View product Compare

Hach Titration Kit: R-SH (Thiol) in Petroleum Products

Hach Titration Kit: R-SH (Thiol) in Petroleum Products

A set of accessories (without reagents) Hach for the determination of R-SH (thiol) in petroleum products.

SKU: AP0017.AT1112

View product Compare

TEST KIT, 5-EP mg/L Hardness

TEST KIT, 5-EP mg/L Hardness

Test kit, hardness; range 20 - 400 CaCO3 mg / L.

SKU: 145401

View product Compare

R4, R8, R12 - Laboratory Mash Bath

R4, R8, R12 - Laboratory Mash Bath

The mash bath is designed for use in laboratories of breweries and malt houses. It is designed to determine the extract content of malt using the CONGRESS, HARTONG (20, 45, 65, 80) and ASBC methods. Users can also carry out tests using their own algorithms using the programmable programs TERMOSTAT or PROFILE.

SKU: R4, R8, R12

View product Compare

SKU: DULCOSMOSE BW

View product Compare

Accessories

Accessories

Powder Pillows Chloride 2 Reagent for Chloride Test Kits

Powder Pillows Chloride 2 Reagent for Chloride Test Kits

For the determination of chlorides by argentometric method (silver nitrate).

SKU: 104399

View product Compare

Silver nitrate solution 1.88 N; 100 ml

Silver nitrate solution 1.88 N; 100 ml

The solution is intended for the determination of chlorides in a water sample by drop count titration.

SKU: 2349432

View product Compare

Recommended products