The Hach UVAS plus sc digital UV sensor is designed to determine organic load using spectral absorption coefficient (SAC) in the medium or in the bypass.

Continuous organic load measurement: UVAS plus sc

  • Without sampling and sample preparation
  • Instantaneous measured values
  • Without reagents
  • Self-cleaning probeIm
  • Mersion or flow-through installation

Package includes: UVAS plus sc sensor and user manual


Description

Description

The UVAS plus sc sensor covers a wide range of applications, including: protection of structures from industrial effluents, control of activated sludge processes, control of methanol supply to the BNR based on organic matter content, monitoring of end effluents and the efficiency of UV disinfection processes.
The transmitter can be connected to all SC controllers, providing versatile output options including 4-20mA output, Modbus RS485, Profibus or HART. The entire range of digital controllers is presentedhere.

UVAS plus sc sensor

SKU Measurement
range
Application
LXV418.99.10001 2 - 3000 1 / m aeration basin
LXV418.99.20001 0 - 1500 1 / m aeration basin
LXV418.99.50001 0,1 - 600 1 / m outlet, drinking water, surface water
LXV418.99.90001 0.01 - 60 1 / m drinking water, clear water

The UVAS plus sc technology sensor measures the spectral absorption coefficient of a liquid at a wavelength of 254 nm. SAC 254 is a measure of the organic content of a liquid. The sensor is immersed in liquid without sampling or reagents and provides instant results. Care and maintenance are very easy thanks to the automatic cleaning with the wiping system.

Measuring principle

Organic matter dissolved in water, as a rule, absorbs ultraviolet light. For this reason, the measurement of UV absorption is an independent, cumulative parameter for the concentration of water-soluble organic matter. This method of determining water quality using laboratory photometers without the use of chemical compounds using filtered samples has long been used in drinking water.

DIN 38402 C2 provides for UV absorption measurements using light sources with a wavelength of 254 nm and refers to the value measured on a filtered sample as the spectral absorption coefficient at 254 nm (shortly SAC254), which should be expressed in absorbance per meter. Thus, a direct comparability of the indicators measured in cuvettes with different intensities is achieved and the units of measurement are 1 / m or m 1. The UVAS immersion sensor contains a multibeam absorption photometer with efficient turbidity compensation. The corresponding controller controls the measurement process using a flash lamp photometer, mechanically cleans the measuring window with a cleaner, and also displays the measured SAC254 values in 1 / m. For other general parameters such as COD or TOC, there is a correlation for SAC254 of the same quality.
For media containing particulate matter, the SAC measurement with UVAS should always be supplemented with a particulate matter or turbidity measurement (SOLITAX sc, ULTRATURB sc).

SAK 254 is an independent indicator for dissolved organic water content and assesses like all other parameters. Despite the great similarity, common parameters can only be converted from one to another within certain limits. If there is a correlation between SAC 254 and another common parameter, then the converted values from UVAS sensors can be displayed in mg / L TOCuv (TOC), CSBuv (COD), etc. To determine the correlation, it is necessary to plot the SAC measurement curve over several days. Only a regular daily curve with clearly defined short and long loading times, for example with urban wastewater, provides a good basis for a satisfactory conversion.

Specifications UVAS plus sc

Measurement
method
UV absorption measurement
Standard SAC 254 according to DIN 38404 C3
Measurement path 1, 2, 5 and 50 mm
Measurement
interval
> 1 min
Cable Length  10 m standard
Additional extension cables are available in lengths of 5, 10, 15, 20, 30, 50 m
Total maximum length: 60 m
Pressure limit max. 0.5 bar
Ambient
temperature
+2 - +40 ° C
Dimensions (D x D) 70 mm x 333 mm
Parameter SAC
Material

gauge: stainless steel 1.4571
cleaner blade: silicone
bypass: PVC

Weight 3.6 kg
Specifications

Specifications

Application areaEnvironmental monitoring, Pharmaceuticals, Wastewater, Drinking water, Treatment facilities, Equipment for water utilities, Medicine, Process control, Water supply
TypeIndustrial
IndustryPharmaceutical, Chemical, Food and Beverage, Municipal
ParametersOrganic load
Measurement Range0 - 1500 1/ м
Measurement methodUV absorption
Measurement Range (2)0.1 - 600 1 / м
Recommended products

Recommended products

SC1000 Probe module for 4 sensors

SC1000 Probe module for 4 sensors

Universal digital controller SC1000, for connecting up to 4 SC sensors with 1 analogue output card with 4 x 0 / 4-20 mA output.

SKU: LXV400.99.00121

View product Compare

SC1000 Probe module for 8 sensors

SC1000 Probe module for 8 sensors

SC1000 Probe module for 8 sensors.

SKU: LXV400.99.20041

View product Compare

Solitax hs-line sc submersible turbidity and suspended solids sensor with wiper

Solitax hs-line sc submersible turbidity and suspended solids sensor with wiper

Immersion probe Solitax hs-line sc for the determination of turbidity (0.001 - 4000 NTU) and suspended solids (0.001 - 500 g / l), with a wiper, stainless steel.

SKU: LXV423.99.00200

View product Compare

Sludge level sensor Sonatax sc

Sludge level sensor Sonatax sc

Sonatax sc sensor with magnetic coupling, stainless steel housing in the range 0.2 - 12 m.

SKU: LXV431.99.00001

View product Compare

Accessories

Accessories

Display module for multi-parameter controller SC1000

Display module for multi-parameter controller SC1000

Touch display for SC1000 universal digital controller.

SKU: LXV402.99.00001

View product Compare

SC4500 digital controller

SC4500 digital controller

The SC4500 is a dual channel controller for digital analytical devices (such as sensors and analyzers). The controller shows sensor measurements and other data on the display, can transmit analog and digital signals, and can also interact with other devices and control them through outputs and relays.

SKU: LXV525.99C11551

View product Compare

Recommended products