Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Titration Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

CL17sc Colorimetric Chlorine Analyzer, Ultra Low Range 0.008 - 5.0 mg/L Cl2

hach-cl17sc-analizator-khlora-sverhnizkij-diapazon.jpgcl17sc analyzer installation optionhach cl17sc and sc4500 controllerustroystvo-analizatora-khlora.jpg

SKU: 9790400, 9790500

Manufacturer: Hach

Availability: Order only

Order Add to comparison

The Ultra Low Range CL17sc analyzer measures total chlorine in water from 10 to 5000 ppb (µg/L) / 0.008 to 5 mg/L Cl2 at 150 second intervals.

  • 9790500 CL17 sc with pressure regulator installation kit
  • 9790400 CL17 sc with standpipe installation kit

The chlorine analyzer connects to the SC controller for power, operation, data collection and communication, and diagnostics. Controller sold separately. The available controller models can be found at the link.


Description

Description

The Hach CL17sc Ultra Low Chlorine Detection Range is best suited for clean water that measures either low levels of chlorine or the absence of chlorine, such as dechlorinated water. Applications may also include any process involving nanofiltration or reverse osmosis membranes. Industries range from energy, semiconductor and pharmaceuticals to beverages, petrochemicals and drinking water.

Whether drinking water, process water or waste water, the CL17sc provides the direct chlorine measurements you need to optimize your water treatment process. The colorimetric analyzer eliminates the need for ORP measurement or amperometric analysis methods, as reading accuracy is not affected by changes in sample pH, temperature, or Cl2 concentration.

Which model to choose?

CL17sc Package Contents: CL17sc Low Range Colorimetric Chlorine Analyzer, standpipe installation kit OR pressure regulator installation kit, Tubing Kit (Includes Stirrer) and User Manual. Kit does not include reagents, screws and/or mounting anchors.

There are two installation kits to choose from when purchasing, both of which are designed to control the sample feed pressure to the analyzer. So, which one to choose?

  • Standpipe installation kit does the job perfectly in any conditions. The pipe has no moving parts, which makes it very reliable. This type of installation requires two feet (about 60 cm) of space above the top of the analyzer, keep this in mind when thinking about the installation location.
  • Pressure regulator installation kit: Works well in all conditions, except when the sample pressure is consistently at the lower limit of the analyzer specification. This installation kit is compact, so it is the best choice if there is not enough space above the analyzer to mount it on a pipe.

How the Hach CL17 sc ULR Analyzer Works

The CL17sc ultra-low range colorimetric chlorine analyzer is equipped with three working components:

  • Inline peristaltic pump for precise volume control of incoming samples and reagents
  • Colorimeter
  • Indicator and buffer solutions

Zero reference point is set at the beginning of the cycle by measuring blank absorbance (this compensates for the color intensity and turbidity of the sample prior to chlorine measurement.) The indicator and buffer solutions are then added to the sample. The solution is stirred with a magnetic stirrer, as a result, the sample changes color. The colorimeter then measures the light that has passed through the sample. The measured intensity is compared with a reference standard. Finally, the sample cell is flushed with new sample. The cycle can be repeated every 2.5 minutes.

Technical details

  • Accuracy: ± 5% or ± 0.01 mg/L (whichever is greater) from 0 - 4 mg/L; ± 10% from 4 - 5 mg/L
  • Alerts: Low and high chlorine. Dirty cell. Low and high sample flow.
  • Controller compatibility: SC200, SC1000, SC1500, SC4200c, SC4500
  • Cycle time: 2.5 minutes
  • Detection limit: 0.008 mg/L Cl2 at 25 °C
  • Dimensions (H x W x D): 342 mm x 329 mm x 177 mm
  • Drain: ½-inch ID flexible hose
  • Enclosure waterproof rating: IP66
  • Flow rate: 60 - 200 mL/min through the instrument
  • Inlet: ¼-inch OD polyethylene tube, quick-disconnect fitting
  • Inlet pressure: 0.3 - 5.2 bar supplied to Y-strainer; 0.1 - 0.3 bar supplied to analyser
  • Interferences: Other oxidising agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO₃.
  • Light source: LED, measurement at 510 nm, 1 cm light pathlength
  • Measuring range: 0.008 - 5 mg/L Cl2
  • Operating temperature range: 5 - 40 °C
  • Parameter: Chlorine, free; Chlorine, total residual
  • Power requirements (Voltage): 12 VDC, 400 mA maximum (supplied by the controller)
  • Reagent consumption: 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
  • Sample requirements: Y-strainer filtration with 40-mesh screen or higher
  • Sample temperature: 5 - 40 °C
  • Weight: 4.1 kg without reagents
Specifications

Specifications

Application areaEnvironmental monitoring, Wastewater, Drinking water, Treatment facilities, Equipment for water utilities, Process control
TypeIndustrial
IndustryChemical, Food and Beverage, Municipal, Semiconductor
ParametersChlorine total
Measurement Range0.008 - 5 mg/L Cl2
Measurement methodColorimetric
MethodDPD
Recommended products

Recommended products

CL17 sc Photometric Chlorine Analyzer

CL17 sc Photometric Chlorine Analyzer

The Hach CL17 sc analyzer is used for continuous monitoring and determination of the concentration of free or total residual chlorine in water. Readings are not affected by changes in chlorine concentration, sample pH, temperature, flow rate, or pressure. The CL17 sc is also suitable for measuring residual permanganate content. Research demonstrates the analyzer's analytical capabilities and confirms that it is a reliable solution and a good tool for managing complex water purification and disinfection processes.

SKU: 8574500, 8574400

View product Compare

Amperometric sensors for total and free chlorine CLT10 sc and CLF10 sc

Amperometric sensors for total and free chlorine CLT10 sc and CLF10 sc

The amperometric sensors CLT10 sc and CLF10 sc complement real-time chemical analysis solutions for free and total chlorine in the laboratory and industry. Amperometric sensors continuously monitor the chlorine concentration without the use of reagents. Measurement range 0 - 20 ppm Cl2.

SKU: LXV45A.98.23022, LXV45B.98.23022

View product Compare

EZ1006 / EZ1007 Free and Total Chlorine Analyzers

EZ1006 / EZ1007 Free and Total Chlorine Analyzers

The EZ Series online analyzers offer several options for monitoring chlorine in water. Typical applications are drinking water, surface water, process water. The EZ1000 Series analyzers use colorimetric method to measure chlorine. EZ1006 Chlorine free. EZ1007 Chlorine, total. Standard measuring range: 0.025 - 1.5 mg / l Cl2.

SKU: EZ1006.99001C02, EZ1007.99001C02

View product Compare

9184 sc Amperometric analyzer for active chlorine

9184 sc Amperometric analyzer for active chlorine

The Chlorine Analyzer 9184sc is a single-channel industrial sensor that measures chlorine concentrations in wastewater treatment plants, potable water production, distribution networks and other applications where monitoring of active chlorine from 0 to 20 mg/L HOCl is required.

SKU: LXV432.99.00001, LXV430.99.00001

View product Compare

Accessories

Accessories

CL17sc analyzer optics cleaning solution

CL17sc analyzer optics cleaning solution

The set contains sulfuric acid (100 ml dropper bottle) and cotton swabs (10).

SKU: 8573100

View product Compare

Calibration Verification set for chlorine analyzers CL17sc

Calibration Verification set for chlorine analyzers CL17sc

The kit includes the necessary reagents and accessories to complete the Cl17sc Series Chlorine Analyzer Calibration Check procedure.

SKU: 8568200

View product Compare

Reagent set for chlorine analyzer CL17sc, ultra low range

Reagent set for chlorine analyzer CL17sc, ultra low range

The reagent kit includes a total chlorine indicator solution, a total chlorine buffer solution, and a DPD compound.

SKU: 9791100

View product Compare

Related products

SC200 Digital 2-channel controller

SC200 Digital 2-channel controller

HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.

SKU: LXV404.99.00551

View product Compare

SC1000 Probe module for 4 sensors

SC1000 Probe module for 4 sensors

Universal digital controller SC1000, for connecting up to 4 SC sensors with 1 analogue output card with 4 x 0 / 4-20 mA output.

SKU: LXV400.99.00121

View product Compare

Display module for multi-parameter controller SC1000

Display module for multi-parameter controller SC1000

Touch display for SC1000 universal digital controller.

SKU: LXV402.99.00001

View product Compare

SC4500 digital controller

SC4500 digital controller

The SC4500 is a dual channel controller for digital analytical devices (such as sensors and analyzers). The controller shows sensor measurements and other data on the display, can transmit analog and digital signals, and can also interact with other devices and control them through outputs and relays.

SKU: LXV525.99C11551

View product Compare


Show more

Recommended products