COD standard solution.

Сoncentration 300 mg/L O2.

200 mL bottle.


Description

Description

The use of standard solutions can provide control of the laboratory process, increase confidence, and help provide a clear demonstration of performance to various inspectors, regulatory agencies and clients. One-parameter analysis can be performed on different analyzed samples and concentrations to confirm accuracy.

COD standard solution (1218629) from Hach for one-parameter water analysis. For accuracy checks in Chemical Oxygen Demand (COD) determinations. 200 mL bottle.

Application: For water and wastewater. Digestion is required. 

Parameter: COD.

Platform: Solution.

Summary of method: The results in mg/L COD are defined as the milligrams of O2 consumed per liter of sample under the conditions of this procedure. The sample is heated for 2 hours with sulfuric acid and a strong oxidizing agent, potassium dichromate. Oxidizable organic compounds react, reducing the dichromate ion (Cr2O7 2–) to green chromic ion (Cr3+). When the 0.7–40.0 or the 3–150 mg/L colorimetric method is used, the amount of Cr6+ that remains is measured. When the 20–1500 mg/L or 200–15,000 mg/L colorimetric method is used, the amount of Cr3+ that is produced is measured. The COD reagent also contains silver and mercury ions. Silver is a catalyst, and mercury is used to complex chloride interferences

Specifications

Specifications

Application areaWastewater, Drinking water, Laboratory analysis
TypeStandard solutions - one-parameter analysis
IndustryEcology, Pulp and paper, Pharmaceutical, Glass, Power generation, Transport, Chemical, Food and Beverage, Municipal
ParametersCOD
Concentration300 mg/L O2
Quantity200 mL
Downloads

Downloads

Oxygen Demand, Chemical-Reactor Digestion COD Method 8000 ULR, LR, HR, HR plus+
Recommended products

Recommended products

Chlorine standard solution, 25 - 30 mg/L Cl2 (NIST)

Chlorine standard solution, 25 - 30 mg/L Cl2 (NIST)

Chlorine standard solution, concentration 25 - 30 mg/L Cl2.

SKU: 2630020

View product Compare

Sulfuric Acid Standard Solution, 0,04 N

Sulfuric Acid Standard Solution, 0,04 N

Sulfuric acid standard solution, 0,04 N, 500 ml bottle.

SKU: 2339349

View product Compare

Sodium chloride standard solution, 10000 µS/cm (NIST)

Sodium chloride standard solution, 10000 µS/cm (NIST)

Sodium chloride standard solution, concentration 10000 µS/cm.

SKU: 2972249

View product Compare

Standard solution, barium, 1000 mg/L as Ba (NIST), 100 mL

Standard solution, barium, 1000 mg/L as Ba (NIST), 100 mL

Standard solution, barium, 1000 mg/L as Ba (NIST), 100 mL.

SKU: 1461142

View product Compare

Fluoride Standard Solution, 1 mg/L F

Fluoride Standard Solution, 1 mg/L F

Standard Solution. Fluoride, 1.00 mg/L ±0.02 mg/L F- (NIST). 1 L bottle.

SKU: 29153

View product Compare

Ammonia Standard Solution, 100 mg/L NH3-N, 500 mL

Ammonia Standard Solution, 100 mg/L NH3-N, 500 mL

Ammonia Standard Solution, 100 mg/L NH3-N, 500 mL bottle.

SKU: 2406549

View product Compare

30090854 Standard solution 10 mg/l (chloride)

30090854 Standard solution 10 mg/l (chloride)

The standard chloride solution for an ion selective electrode (ISE) is a solution with a precisely known concentration of chloride ions (Cl⁻). The solution is used to calibrate and test the efficiency of selective electrodes in relation to the concentration of chloride ions in the sample.

SKU: 30090854

View product Compare

Phosphorus Standard Solution, 25 mg/L as P (NIST)

Phosphorus Standard Solution, 25 mg/L as P (NIST)

Phosphorus Standard Solution. For accuracy checks in phosphorus determinations. Concentration: 25 mg/L as P (NIST).

SKU: 2109210

View product Compare

BOD Standard Solution, 300 mg/L О2 (NIST)

BOD Standard Solution, 300 mg/L О2 (NIST)

BOD Standard Solution, concentration 300 mg/L О2 (NIST).

SKU: 1486510

View product Compare

30090852 Standard solution 10 mg/l (fluoride)

30090852 Standard solution 10 mg/l (fluoride)

The standard fluoride solution for an ion selective electrode (ISE) is a solution with a precisely known concentration of fluoride ions (F). The solution is used to calibrate and test the efficiency of selective electrodes in relation to the concentration of fluoride ions in the sample.

SKU: 30090852

View product Compare

Reagent kit Amtax sc with standard, for range 10 - 1000 mg/L NH4-N

Reagent kit Amtax sc with standard, for range 10 - 1000 mg/L NH4-N

LCW866 Reagent Kit for Oline Ammonium Analyzer with Standard Calibration Solutions.

SKU: LCW866

View product Compare

Sodium chloride standard solution, 100 µS/cm (NIST)

Sodium chloride standard solution, 100 µS/cm (NIST)

Sodium chloride standard solution, concentration 100 µS/cm.

SKU: 2971849

View product Compare

Copper standard solution, 100 mg/L as Cu, 100 mL

Copper standard solution, 100 mg/L as Cu, 100 mL

Copper standard solution, 100 mg/L as Cu (NIST), 100 mL.

SKU: 12842

View product Compare

Silver, standard solution, 1000 mg/L as Ag (NIST)

Silver, standard solution, 1000 mg/L as Ag (NIST)

Silver standard solution, 1000 mg/L as Ag (NIST).

SKU: 1461342

View product Compare

Reagent kit Amtax sc with standard, for range 0.02 - 5 mg/L NH4-N

Reagent kit Amtax sc with standard, for range 0.02 - 5 mg/L NH4-N

A set of reagents with standard solutions for calibration.

SKU: LCW889

View product Compare

51344774 Standard solution 1000 mg/l (copper)

51344774 Standard solution 1000 mg/l (copper)

The standard copper solution for an ion selective electrode (ISE) is a solution with a precisely known concentration of copper ions (Cu). The solution is used to calibrate and test the efficiency of selective electrodes in relation to the concentration of copper ions in the sample.

SKU: 51344774

View product Compare

Standard Solution, nickel, 100 mL

Standard Solution, nickel, 100 mL

Standard Solution, nickel, 100 mL. Concentration: 1000 mg/L as Ni (NIST). For accuracy checks in nickel determinations. (HNO3 matrix).

SKU: 1417642

View product Compare

Sulphuric acid standard solution, 0,020 N, 1 L

Sulphuric acid standard solution, 0,020 N, 1 L

Sulphuric acid standard solution, 0,020 N, 1 L bottle.

SKU: 20353

View product Compare

Standard Solution, Manganese, 25 mg/L Mn (NIST), PourRite Ampoules

Standard Solution, Manganese, 25 mg/L Mn (NIST), PourRite Ampoules

Used to check the accuracy of the analysis when determining manganese in a water sample.

SKU: 2112820

View product Compare

Phosphax sc LR Standard Solution S

Phosphax sc LR Standard Solution S

Standard concentration solution for the Phosphax sc LR industrial orthophosphate analyzer.

SKU: LCW958

View product Compare

Sodium chloride standard solution, 1000 µS/cm (NIST)

Sodium chloride standard solution, 1000 µS/cm (NIST)

Sodium chloride standard solution, concentration 1000 µS/cm.

SKU: 1440049

View product Compare

51344771 Calcium standard solution 1000 mg/l

51344771 Calcium standard solution 1000 mg/l

A pre-mixed solution with an accurately known concentration of calcium (Ca) is commonly used to calibrate and verify the accuracy of ion selective electrodes.

SKU: 51344771

View product Compare

Sodium chloride standard solution, 1000 µS/cm (NIST)

Sodium chloride standard solution, 1000 µS/cm (NIST)

Sodium chloride standard solution, concentration 1000 µS/cm.

SKU: 1440042

View product Compare

Sulphuric acid standard solution, 0,035 N, 100 mL

Sulphuric acid standard solution, 0,035 N, 100 mL

Sulphuric acid standard solution, 0,035 N, 100 mL marked drpping bottle (MDB).

SKU: 2349732

View product Compare