Solitax t-line sc, immersion turbidity sensor, 0.001 - 4000 NTU, PVC
SKU: LXV423.99.10000, LXV423.99.12000
Manufacturer: Hach
Availability: Order only
- Turbidity sensor Solitax ts-line sc with wiper (LXV423.99.10000)
- Turbidity sensor Solitax ts-line sc without wiper (LXV423.99.12000)
Scope of Delivery: submersible turbidity sensor (cable 10 meters), user manual.
Operating temperature range: 0-40 ° C
The sensor can be used in conjunction with Hach controllers. Controllers are available to order separately.
LDO sc process dissolved oxygen sensor; cable 10 meters
SKU: LXV416.99.20001
Solitax highline sc turbidity and suspended solids sensor, stainless steel
SKU: LXV424.99.00200, LXV424.99.02200
Solitax ts-line sc submersible turbidity and suspended solids probe, stainless steel
SKU: LXV423.99.00100, LXV423.99.02100
Description Specifications Downloads Recommended products
Description
Description
Precision turbidity sensor; compliance with DIN EN ISO 7027
Hach Solitax sc sensors provide accurate, color-independent measurement of turbidity and suspended solids in drinking water and wastewater. Self-cleaning device (wiper) prevents biological growth and the ingress of gas bubbles. The reliable operation of this system and the possibility of complete data transfer help improve process control.
Excellent correlation with laboratory analysis
Solitax sc sensors show exceptional correlation with laboratory analysis. Real-time measurements not only save manual analysis time, but also provide important real-time measurements that can be used to more efficiently operate the installation.
Fully serviceable sensors
Solitax sc sensors are fully serviceable, which often doubles their lifespan.
Simple one-point calibration
Factory calibrated according to DIN EN ISO 7027 to ensure long term calibration stability. Calibration is performed using a simple factor correction procedure.
Multi-channel, multi-parameter system
Several Solitax sc sensors can be installed on one Hach SC controller. The same controller can also support any combination of parameters. All sc Hach probes are "plug and play" and require no complicated wiring or configuration.
The measuring principle is based on a combined infrared absorption scattered light technique that measures the lowest turbidity values in accordance with DIN EN 27027 just as precisely and continuously as high sludge content. Using this method, the light scattered sideways by the turbidity particles is measured over an angle of 90°. The measurement data is displayed and processed with the help of a controller.
Specifications
Application area | Environmental monitoring, Wastewater, Drinking water, Beverages, Process control |
Type | Industrial |
Industry | Ecology, Pulp and paper, Pharmaceutical, Glass, Power generation, Transport, Chemical, Food and Beverage, Municipal |
Parameters | Turbidity |
Downloads
User Manual: Solitax t-line sc Turbidity immersion probe, 0,001 - 4000 NTU (LXV423.99.10000, LXV423.99.12000) |
Recommended products
SC200 Digital 2-channel controller
HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.
SKU: LXV404.99.00551
1200-S sc Digital pH sensor for SC controller
Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.
SKU: LXV426.99.10001
SC1000 Probe module for 8 sensors
SC1000 Probe module for 8 sensors.
SKU: LXV400.99.20041
Solitax highline sc turbidity and suspended solids sensor, stainless steel
Solitax highline sc inline sensor for turbidity (0.001 - 4000 NTU) and suspended solids (0.001 - 500 g / l), stainless steel.
SKU: LXV424.99.00200, LXV424.99.02200
Solitax ts-line sc submersible turbidity and suspended solids probe, stainless steel
Immersion probe Solitax ts-line sc for the determination of turbidity (0.001 - 4000 NTU) and suspended solids (0.001 - 50 g / l). Material - stainless steel
SKU: LXV423.99.00100, LXV423.99.02100
Recommended products
SC200 Digital 2-channel controller
HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.
SKU: LXV404.99.00551
1200-S sc Digital pH sensor for SC controller
Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.
SKU: LXV426.99.10001
SC1000 Probe module for 8 sensors
SC1000 Probe module for 8 sensors.
SKU: LXV400.99.20041
Solitax highline sc turbidity and suspended solids sensor, stainless steel
Solitax highline sc inline sensor for turbidity (0.001 - 4000 NTU) and suspended solids (0.001 - 500 g / l), stainless steel.
SKU: LXV424.99.00200, LXV424.99.02200
Solitax ts-line sc submersible turbidity and suspended solids probe, stainless steel
Immersion probe Solitax ts-line sc for the determination of turbidity (0.001 - 4000 NTU) and suspended solids (0.001 - 50 g / l). Material - stainless steel
SKU: LXV423.99.00100, LXV423.99.02100