Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Titration Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

Amperometric chlorine dioxide analyzer 9187 sc

hach-9187-sc-analizator-dioksida-hlora.jpgacidification and purification unit 9180sc LZY051

SKU: LXV434.99.00001

Manufacturer: Hach

Availability: Order only

Order Add to comparison

The Hach 9187 sc Complete Chlorine Dioxide System comes pre-wired on a panel (no controller included). To get started, you just need to install the panel at the monitoring site, insert the sensors and connect the controller. The membrane system of the sensor means no reagents are needed for measurements and maintenance is minimized.

Scope of delivery: panel for Hach 9187sc sensor, ClO2 sensor, 4 spare membranes, electrolyte, sensor cable and user manual.


Description

Description

Selective membrane eliminates chlorine interference

The Hach 9187sc amperometric ClO2 sensor uses a membrane that is selective for chlorine dioxide species. Bromine, chlorine or hydrogen peroxide will not interfere with the readings. Ozone may interfere, but is rarely present in chlorine dioxide-treated water.

Options for the 9187sc chlorine dioxide sensor:

  • 9180sc Acidification / Cleaning Unit (LZY051) for amperometric sensors: for most amperometric measurements there are optimum pH ranges in which they will be most accurate. The addition of an acidifying / cleaning device can provide assurance that the samples are in the range suitable for measurement.

Compatible with Hach multi-parameter digital controllers

The Hach 9187sc is used with Hach digital controllers. Hach sc series digital controllers can accomodate from two to eight sensors. Several sc controllers can be networked to connect more sensors and therefore measure more parameters at the same time, which reduces the cost of the measuring point.

Simply plug in any Hach “plug and play” digital sensor and it's ready to go with no software setup. Plug and play connectivity means no complicated wiring or setup is required. Connect the 9187sc amperometric chlorine dioxide sensor to the controller in combination with any of the Hach digital sensors and measure dissolved oxygen, turbidity, ORP, conductivity and other key water parameters in your process in parallel.

Principle of operation

The measurement is carried out by the amperometric method after chlorine dioxide molecules enter the membrane. Chlorine dioxide molecules contained in the sample diffuse through the membrane and are then detected in a very thin electrolyte zone between the membrane and the cathode. A constant working potential is applied to the working electrode (cathode), where CIO2 decreases in accordance with the reaction:

ClO2 + 5e + 4H+ ♦ Cl + 2H2O

On a silver electrode (anode), silver is oxidized to:

Ag +: Cl + Ag ♦ AgCl + e

Decreasing chlorine dioxide at the cathode generates a current that is directly proportional to its partial pressure in the sample. The electrochemical reaction and diffusion through the membrane are temperature dependent; therefore, the measuring cell is equipped with a temperature sensor, which automatically compensates for changes in measurement depending on temperature.

Specifications

Accuracy 5% or ±10 ppb ClO2, whichever is greater
Calibration interval 2 months
Detection limit 0.01 mg/L ClO2
Enclosure waterproof rating IP66 / NEMA 4X
Flow 14 L/h (200 - 250 mL/min) auto-regulated by flow through cell
Sample temperature 2 - 45 °C
Interferences none
Maintenance interval 6 months for membrane and electrolyte (measurement cell)
Measuring range 0 - 2 mg/L ClO2
Operating temperature range 0 - 45 °C
Storage conditions - 20 - 60 °C
Specifications

Specifications

Application areaDrinking water, Process control
TypeIndustrial
IndustryFood and Beverage
ParametersChlorine dioxide
Measurement Range0 - 2 mg/L ClO2
Recommended products

Recommended products

SC200 Digital 2-channel controller

SC200 Digital 2-channel controller

HACH LANGE is a recognized leader in water analysis solutions. More than 40 different analog and digital sensors can be combined with the SC 200. Thanks to its robust metal housing, the SC 200 is suitable for industrial applications.

SKU: LXV404.99.00551

View product Compare

SC1000 Probe module for 4 sensors

SC1000 Probe module for 4 sensors

Universal digital controller SC1000, for connecting up to 4 SC sensors with 1 analogue output card with 4 x 0 / 4-20 mA output.

SKU: LXV400.99.00121

View product Compare

Display module for multi-parameter controller SC1000

Display module for multi-parameter controller SC1000

Touch display for SC1000 universal digital controller.

SKU: LXV402.99.00001

View product Compare

SC4500 digital controller

SC4500 digital controller

The SC4500 is a dual channel controller for digital analytical devices (such as sensors and analyzers). The controller shows sensor measurements and other data on the display, can transmit analog and digital signals, and can also interact with other devices and control them through outputs and relays.