Stablcal Standards Calibration Kit. USEPA accepted for calibration purposes.

Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter.

Kit includes 100 mL bottles of 1.0, 10, 100 and 1000 NTU standard.


Description

Description

Stablcal Standards Calibration Kit from Hach (2659110). Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. 

Precise, Pre-mixed Formazin Solutions

With proprietary manufacturing technology, Stablcal Standards in precise concentrations at a wide variety of concentrations - providing accurate turbidimeter calibrations.

Based on Formazin Primary Standards

Stablcal Stabilized Formazin Standards contain the same light scattering polymer as traditional Formazin primary turbidity standards - and perform equivalently.

Enhanced Stability Saves Time and Labor

While Formazin primary standards can be prepared directly in the lab, the process is labor intensive and time consuming - and the diluted standards are not stable. Stablcal is a stabilized version of Formazin - providing repeatable results, without the time and effort required for lab-prepared standards.

Confidence in results

Stablcal standards are based on decades of experience in turbidity measurement.

Specifications

Specifications

Application areaPharmaceuticals, Wastewater, Drinking water, Laboratory analysis
TypeTurbidity Standards
IndustryEcology, Pulp and paper, Pharmaceutical, Glass, Power generation, Transport, Chemical, Food and Beverage, Municipal
ParametersTurbidity
CompatibilityTL2350 EPA, TL2360 ISO
Concentration 1,0, 10, 100, 1000 NTU
Quantity
Recommended products

Recommended products

Stablcal turbidity Standards Calibration Kit, 100 mL / 500 mL

Stablcal turbidity Standards Calibration Kit, 100 mL / 500 mL

Stablcal Standards Calibration Kit. Stablcal Stabilised Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. Concentration < 0,1, 20, 200, 1000, 4000, 7500 NTU.

SKU: 2659510, 2659500

View product Compare

Stablcal Certified Standard, 0,060 NTU

Stablcal Certified Standard, 0,060 NTU

Formazin Certified Standard Stablcal. Concentration: 0,060 NTU.

SKU: 2805342

View product Compare

Stablcal Formazine Reference Suspension I, 3 NTU

Stablcal Formazine Reference Suspension I, 3 NTU

Stabilised Formazine reference suspension for the determination of lucidity/opalescence. Concentration 3 NTU.

SKU: 2896742

View product Compare

Stablcal Ampule Calibration Kit, Formazin, for portable turbidimeter

Stablcal Ampule Calibration Kit, Formazin, for portable turbidimeter

Stablcal Ampule Calibration Kit, Formazin. Used for calibration of the 2100Q, 2100Q IS Turbidity Meters. Stablcal Stabilized Formazin Turbidity Standards are formazin dilutions designed for use in a turbidimeter. Concentration: 10, 20, 100, 800 NTU.

SKU: 2971205

View product Compare

Stablcal Reference Suspension Set w/Cells

Stablcal Reference Suspension Set w/Cells

Stabilised Formazine reference suspension for the determination of lucidity/opalescence. Kit includes ampules of each: <0,1, 3, 6, 18, 30.

SKU: 2897100

View product Compare

Stablcal Turbidity Standards Calibration Kit, 0 - 7500 NTU

Stablcal Turbidity Standards Calibration Kit, 0 - 7500 NTU

Six ready to use, stabilised Formazin Primary standard solutions. Kit includes sealed vials of each: <0,1 NTU, 20 NTU, 200 NTU, 1000 NTU, 4000 NTU, 7500 NTU.

SKU: 2659505

View product Compare

Stablcal Stabilised Formazine Turbidity Standard, 20 NTU, 100 mL / 500 mL

Stablcal Stabilised Formazine Turbidity Standard, 20 NTU, 100 mL / 500 mL

Ready to use, stabilised Formazine Primary standard solution in bottle, 20 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2660142, 2660149

View product Compare

Stablcal Turbidity Standard, 800 NTU, 100 mL / 500 mL

Stablcal Turbidity Standard, 800 NTU, 100 mL / 500 mL

Ready to use, stabilised Formazine Primary standard solution in bottle, 800 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2660542, 2660549

View product Compare

Calibration kit, Stablcal turbidity standards, 100 mL / 500 mL

Calibration kit, Stablcal turbidity standards, 100 mL / 500 mL

Stablcal Standards Calibration Kit. Stablcal Stabilised Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. Concentration < 0,1, 20, 100, 800 NTU.

SKU: 2659400, 2659410

View product Compare

Stablcal Stabilised Formazine Turbidity Standard, 100 NTU, 100 mL / 500 mL

Stablcal Stabilised Formazine Turbidity Standard, 100 NTU, 100 mL / 500 mL

Ready to use, stabilised Formazine Primary standard solution in bottle, 100 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2660242, 2660249

View product Compare

Stablcal Formazine Reference Suspension II, 6 NTU

Stablcal Formazine Reference Suspension II, 6 NTU

Stabilised Formazine reference suspension for the determination of lucidity/opalescence. Concentration 6 NTU.

SKU: 2896842

View product Compare

Stablcal Turbidity Standards Calibration Kit for 2100Q

Stablcal Turbidity Standards Calibration Kit for 2100Q

Stablcal Standards Calibration Kit. Stablcal Stabilised Formazin Turbidity Standards are true Formazin dilutions developed for use in Hach turbidimeter 2100Q. Concentration < 0,1, 20, 100, 800 NTU.

SKU: 2659405

View product Compare

Stablcal Turbidity Standard, 0,50 NTU

Stablcal Turbidity Standard, 0,50 NTU

Ready to use, stabilised Formazine Primary standard solution in bottle, 0,50 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2698042

View product Compare

Stablcal Reference Suspension Set, bottles, 100 mL

Stablcal Reference Suspension Set, bottles, 100 mL

Stabilised Formazine reference suspension for the determination of lucidity/opalescence. Kit includes 100 mL of each <0,1, 3, 6, 18, 30.

SKU: 2897200

View product Compare

Stablcal Stabilised Formazine Turbidity Standard 10,0 NTU, 100 mL / 500 mL

Stablcal Stabilised Formazine Turbidity Standard 10,0 NTU, 100 mL / 500 mL

Ready to use, stabilised Formazine Primary standard solution in bottle, 10,0 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2659942, 2659949

View product Compare

Silicone oil, 15 mL SCDB

Silicone oil, 15 mL SCDB

Silicone oil, 15 mL. Multiple uses, including preparation of turbidity sample cells, for TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 126936

View product Compare

Stablcal Turbidity Standard, 0,30 NTU

Stablcal Turbidity Standard, 0,30 NTU

Ready to use, stabilised Formazine Primary standard solution in bottle, 0,30 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2697942

View product Compare

Stablcal Reference Suspension III, 18 NTU

Stablcal Reference Suspension III, 18 NTU

Stabilised Formazine reference suspension for the determination of lucidity/opalescence. Concentration 18 NTU.

SKU: 2896942

View product Compare

Stablcal Stabilised Formazine Turbidity Standard 1,0 NTU, 100 mL / 500 mL

Stablcal Stabilised Formazine Turbidity Standard 1,0 NTU, 100 mL / 500 mL

Ready to use, stabilised Formazine Primary standard solution in bottle. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. NTU Value: 1,0. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2659842, 2659849

View product Compare

Stablcal Reference Suspension IV, 30 NTU

Stablcal Reference Suspension IV, 30 NTU

Stabilised Formazine reference suspension for the determination of lucidity/opalescence. Concentration 30 NTU.

SKU: 2897042

View product Compare

Stablcal calibration kit, 2100Q, 100 mL / 500 mL

Stablcal calibration kit, 2100Q, 100 mL / 500 mL

Stablcal Standards Calibration Kit. Used for calibration of the 2100Q Turbidity Meter. Stablcal Stabilized Formazin Turbidity Standards are formazin dilutions designed for use in a turbidimeter. Concentration: 20, 100, 800, 10 NTU (for verification).

SKU: 2971200, 2971210

View product Compare

Stablcal Turbidity Standard, 200 NTU, 100 mL / 500 mL

Stablcal Turbidity Standard, 200 NTU, 100 mL / 500 mL

Ready to use, stabilised Formazine Primary standard solution in bottle, 200 NTU. Stablcal Stabilized Formazin Turbidity Standards are true Formazin dilutions. Suitable for all turbidimeters. For TL23, TU52, 2100Q, TL2300, TL2350 series.

SKU: 2660442, 2660449

View product Compare

Stablcal calibration kit for TU5200, TU5300sc and TU5400sc laser RFID turbidimeters

Stablcal calibration kit for TU5200, TU5300sc and TU5400sc laser RFID turbidimeters

Precise, premixed formazin solutions.

SKU: LZY835

View product Compare

Calibration kit, Stablcal turbidity standards, 100 mL / 500 mL

Calibration kit, Stablcal turbidity standards, 100 mL / 500 mL

Stablcal Standards Calibration Kit. Stablcal Stabilised Formazin Turbidity Standards are true Formazin dilutions developed for use in any turbidimeter. Concentration < 0,1, 20, 200, 1000, 4000 NTU.

SKU: 2662100, 2662110

View product Compare

Recommended products