Meters and probes pH Oxygen Conductivity Portable labs Spectrophotometry Turbidimetry Colorimetry Process equipment Online analyzers Refractometers and densitometers Reagents and standards HACH Laboratory equipment Process filtration Quality control of packaging Microbiology Accessories

Probes and sensors

lab and field probesThis section of the catalog presents a wide selection of Hach Lange Intellical probes and electrodes for the most demanding laboratory and field tasks in the following parameters: pH, dissolved oxygen, BOD, conductivity, TDS, ORP, ammonia, ammonium, chloride, fluoride, nitrate and sodium. All Intellical probes are automatically recognized by the HQ / HQD series meters and retain their calibration data, eliminating the need to recalibrate when switching between meters. The Red Rod pH electrodes provide exceptional performance and response times for a wide variety of sample types in the laboratory. The rugged outdoor sensors are housed in a stainless steel housing and, thanks to digital technology, can be used with cables up to 30 meters. In addition to sensors and electrodes, this section contains solutions for sensor maintenance, conductivity standards and pH buffers.

Filters

Filters

Reset

Application area

Type

Industry

Brand name

Parameters

Measurement Range

Accuracy

Operating temperature range

Features

Sensor type

Compliance with the standard

Number of tests

Measurement Range (2)

Concentration

Reset

Sorting: 

Ion Selective Electrode (ISE) Intellical ISENH4181, ammonium (NH4 +) with calibration reagents

Ion Selective Electrode (ISE) Intellical ISENH4181, ammonium (NH4 +) with calibration reagents

The Intellical Ammonium ISE Analysis Package contains everything you need to determine ammonium (NH4 +) with the HQD series meters.

SKU: ISENH4181AP

View product Compare

Field ORP / redox electrode Intellical MTC101; cable length 5, 10, 15, 30 m

Field ORP / redox electrode Intellical MTC101; cable length 5, 10, 15, 30 m

Intellical MTC101 is a digital combined redox potential (ORP / redox) electrode with built-in temperature sensor.

SKU: MTC10105, MTC10110

View product Compare

Buffer Solution, pH 7,00

Buffer Solution, pH 7,00

Buffer Solution, concentration pH 7,00± 0,02, 500 mL.

SKU: 1222249

View product Compare

Calibration solution ph 7.00, 250 mL

Calibration solution ph 7.00, 250 mL

Buffer solution for calibration and accuracy check of pH electrodes and hydrogen ion meters, pH is 7.00 ± 0.02 pH at 25 °C

SKU: LZW9464.98

View product Compare

Conductivity calibration solution 12.88 mS/cm, KCl, 125 mL

Conductivity calibration solution 12.88 mS/cm, KCl, 125 mL

Standard conductivity solution. 12.88 mS/cm ± 0.11 mS/cm @ 25 °C. Potassium chloride (KCl) (0.1 M). Bottle 125 ml.

SKU: LZW9721.99

View product Compare

1200-S sc digital online ORP sensor for SC series controllers

1200-S sc digital online ORP sensor for SC series controllers

Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.

SKU: LXV426.99.20001

View product Compare

SKU: HP-200

View product Compare

SKU: 741036

View product Compare


Sorting: 

Ion Selective Electrode (ISE) Intellical ISENH4181, ammonium (NH4 +) with calibration reagents

Ion Selective Electrode (ISE) Intellical ISENH4181, ammonium (NH4 +) with calibration reagents

The Intellical Ammonium ISE Analysis Package contains everything you need to determine ammonium (NH4 +) with the HQD series meters.

SKU: ISENH4181AP

View product Compare

Field ORP / redox electrode Intellical MTC101; cable length 5, 10, 15, 30 m

Field ORP / redox electrode Intellical MTC101; cable length 5, 10, 15, 30 m

Intellical MTC101 is a digital combined redox potential (ORP / redox) electrode with built-in temperature sensor.

SKU: MTC10105, MTC10110

View product Compare

Buffer Solution, pH 7,00

Buffer Solution, pH 7,00

Buffer Solution, concentration pH 7,00± 0,02, 500 mL.

SKU: 1222249

View product Compare

Calibration solution ph 7.00, 250 mL

Calibration solution ph 7.00, 250 mL

Buffer solution for calibration and accuracy check of pH electrodes and hydrogen ion meters, pH is 7.00 ± 0.02 pH at 25 °C

SKU: LZW9464.98

View product Compare

Conductivity calibration solution 12.88 mS/cm, KCl, 125 mL

Conductivity calibration solution 12.88 mS/cm, KCl, 125 mL

Standard conductivity solution. 12.88 mS/cm ± 0.11 mS/cm @ 25 °C. Potassium chloride (KCl) (0.1 M). Bottle 125 ml.

SKU: LZW9721.99

View product Compare

1200-S sc digital online ORP sensor for SC series controllers

1200-S sc digital online ORP sensor for SC series controllers

Hach offers a wide range of analog and digital pH and ORP sensors to meet your in-line pH or ORP monitoring needs in water or other liquids.

SKU: LXV426.99.20001

View product Compare

SKU: HP-200

View product Compare

SKU: 741036

View product Compare